LUBExpert Case: Greasing a Cement-Plant Fan Exposed Bearing Failure Early
SDT cement-plant case: calendar greasing dosed 50 g every two weeks. LUBExpert Static cut dose to ~16/14 g and, with rising friction plus vibration, caught cooling-fan bearing failure before unplanned downtime.
Мақала орыс тілінде
Мақаланың толық мәтіні қазіргі уақытта орыс тілінде жарияланған. Аударма дайындалуда — толық мәтін үшін орыс нұсқасына өтіңіз.
Орыс тілінде оқу
Source. SDT Ultrasound case by Torki and vibration analyst Khaled Salman Almarwany — cooling-fan bearings at a cement plant with LUBExpert Static + vibration cross-check.
Before: calendar grease
50 g every two weeks on DE and NDE — no friction feedback. Classic path to over-greasing and missed early defects.
After: LUBExpert Static
With LUBExpert, the last successful task used about 16 g (DE) and 14.4 g (NDE).

DE: friction rose after grease — over-lube or damaged bearing.

NDE: friction dropped, yet LUBExpert still flagged suspected bearing failure.
Vibration confirmation
Spectra showed mechanical looseness. Bearings were replaced on a planned shutdown. Overall RMS fell from 8.2 to 2.7. Four days later, new bearings were greased successfully with the same LUBExpert.



Takeaway
Ultrasound cuts grease use and catches the moment when grease no longer helps — repair is required. Pair lubrication techs with vibration analysts. See grease savings. KEG TRK — LUBExpert demo.
Мақаладағы жабдық
LUBExpert - Система управления смазкой подшипников
Управление программой смазки подшипников с базой данных, Shopping List и Work Or...
SDT340 - Продвинутый ультразвуковой детектор
Самый продвинутый ультразвуковой детектор для сбора, анализа и трендирования дан...
LUBEChecker - Контроль смазки подшипников
Специализированный детектор для контроля смазки подшипников в реальном времени