RVI of turbines and heat exchangers: which IPLEX you need
Remote visual inspection for turbines, combustors and heat exchangers — One/NX vs GAir vs TX II
Why RVI when you already have vibration
Vibration tells you that a turbine or pump set has changed its behaviour. A videoscope answers a different question: what can you actually see inside the flow path, the combustor, the tube bundle, the header — without a full teardown.
At CHP plants, gas turbine units, compressor and process installations, remote visual inspection (RVI) shortens downtime and raises confidence before restart after a repair.
Model comparison is in the guide "Which IPLEX to choose". Below is the mapping to assets.
Turbines and the hot gas path
Tasks: blades, nozzle assemblies, combustor, transition zones, foreign objects, signs of overheating or erosion.
Usually chosen:
- IPLEX One — a single platform, Swoptix, measurement, digital reporting;
- or IPLEX NX — if the flagship image quality / 3D is already familiar.
For routine "look and record a video" rounds, GX/GT or G Lite is often enough.
The key items in the specification: access port diameter and whether measurement is required (not just photos).
Heat exchangers and tube bundles
Here length often matters more than a cinematic image.
- Short channels / headers — NX / One / GX.
- Long tubes and runs of 20–30 m — IPLEX GAir with pneumatic articulation.
A common procurement mistake: buying an NX "for everything" and then discovering you physically cannot reach the end of the bundle.
Tight access and castings
Openings around 2 mm, small cavities, guides — this is IPLEX TX II territory (flexible ~2.2 mm / rigid ~1.8 mm).
A frequent scheme: TX II finds the zone of interest → a 4–6 mm system performs the detailed inspection and measurement.
Mini matrix for your enquiry
| Asset | Length | Access | Model |
|---|---|---|---|
| Turbine / combustor | 2–10 m | 4–8 mm | One / NX / GX |
| Long heat exchanger | 20–30 m | ~8.5 mm | GAir |
| Narrow opening | up to ~1.2 m | 1.8–2.2 mm | TX II |
| Quick walkdown | 2–5 m | standard | G Lite / GX |
How to build it into an outage
- Before shutdown — a plan of RVI points (what must be seen).
- During the outage — imaging plus measurement of critical defects.
- In the report — the frame, insertion depth / position, verdict, recommendation.
- After the repair — a repeat RVI of the control zones.
That is how IPLEX becomes part of the start-up procedure rather than "a camera for curiosity".
Catalogue — /products/endoscopes. Configuration selection — /proizvoditeli/olympus.
Read also
7/22/2026
Which IPLEX videoscope to choose: One, NX, GX/GT, GAir or TX II
Olympus IPLEX comparison: when you need IPLEX One, NX, GX/GT, long-reach GAir or ultra-thin TX II
6/30/2026
Artesis e-PCM for Diesel Generators: Backup Power Monitoring Without Shaft Sensors
Diesel gensets at CHPs, oil & gas sites and data centres: how e-PCM monitors engine and generator from output current and voltage — early warning before grid failure exposes a dead unit.
7/23/2026
Corrosion monitoring of pipes and vessels at power plants and refineries
How to build a field thickness-gauging route on TPP and refinery assets with Olympus 39DL/38DL