Supply in Kazakhstan
KEG TRK supplies SF6 gas analysis solutions (Cambridge Sensotec) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.
Key features
Applications and resources
Industry solutions, landing pages and articles about Rapidox SF6 6100 Pump Back - Gas Analyzer with Gas Return
Where it is used
Typical tasks
- High-voltage circuit breakers with gas return
- Gas-insulated lines (GIL)
- SF6-insulated transformers
- SF6 savings during diagnostics
- Environmentally safe analysis
Field SF6 quality analyzer with pump-back function — minimizes gas loss during HV equipment testing.
Description
The Rapidox SF6 6100 Pump Back is a premium, fully automatic SF6 gas analyzer from Cambridge Sensotec (United Kingdom) featuring a unique function that returns gas back into the equipment after analysis. It is a Zero Emission solution that minimizes losses of expensive SF6 gas and protects the environment.
Key Difference: Pump Back Function
What is Pump Back?
Pump Back is a built-in SF6 gas return system:
- Sampling — gas is drawn from the equipment
- Analysis — measurement of all quality parameters
- Return — clean SF6 is pumped back
- Result — minimal gas loss
Why is gas return needed?
Economic benefits
- SF6 is an expensive gas — priced up to $100+ per kg
- Loss minimization — return of up to 99% of gas
- Refill savings — fewer purchases of new gas
- Fast payback — within a few analyses
Environmental benefits
- SF6 is a greenhouse gas — 23,500 times more potent than CO2
- Zero Emission — zero emissions into the atmosphere
- Kyoto Protocol compliance — reduction of emissions
- Environmental responsibility — green technologies
Operational benefits
- No pressure drop — gas is returned to the system
- No equipment downtime — no refilling required
- Fast analysis — automatic cycle
- Safety — minimal gas handling
Technical Specifications
Measurement parameters
| Parameter | Range | Accuracy |
|---|---|---|
| SF6 (purity) | 0 — 100% | ±0.5% |
| Moisture (Td) | -60°C to +20°C | ±2°C |
| SO2 | 0 — 1000 ppm | ±5% |
| H2S | 0 — 1000 ppm | ±5% |
| Other gases | Up to 8 simultaneously | Per specification |
Pump system
| Characteristic | Value |
|---|---|
| Pump type | Built-in vacuum |
| Capacity | Automatic |
| Gas return | Up to 99% |
| Return pressure | As in the equipment |
Physical parameters
| Parameter | Value |
|---|---|
| Display | 7" touchscreen TFT (180 mm) |
| Protection | IP66 (Peli case) |
| Weight | 21 kg with case |
| Dimensions | 500 × 400 × 250 mm |
| Battery | Li-Ion, up to 8 hours |
| Case | Peli with wheels and handle |
Full Automation
Walk Away Timer
- Start delay — "walk away and return" timer
- Automatic start — analysis begins on a timer
- Free time — attend to other tasks
- Auto-completion — full cycle without intervention
Auto-Abort Function
- Error control — automatic problem detection
- Safe shutdown — in the event of deviations
- Equipment protection — prevents damage
- Diagnostics — error reporting
Auto-Clean Function
- Sensor cleaning — after each measurement
- Extended service life — sensors last longer
- Accuracy — stable results
- Automatic — no operator involvement
Operating Modes
Standard Pump Back mode
- Connection to the test valve
- Sampling — automatic gas draw
- Analysis — measurement of all parameters
- Return — pumping SF6 back
- Report — saving results
Gas Cylinder Mode
- Analysis of SF6 from cylinders
- Quality verification of new gas
- Control of gas for refilling
- Acceptance testing
Direct Mode
- Measurement without return
- For systems without gas return
- Rapid analysis
Built-in Tests and Standards
CIGRE Tests
International tests for SF6 equipment:
- CIGRE B3.02 — SF6 quality analysis
- CIGRE TF — working group recommendations
- Automatic protocols — format compliance
IEC Standards
- IEC 60480 — used SF6 gas
- IEC 62271-100 — high-voltage switchgear
- IEC 62067 — SF6 cable lines
- Automatic evaluation — pass/fail against standards
Unique Technologies
Rapidri System
- Accelerated operation — faster than standard cycles
- Special procedure — optimized analysis
- Time savings — up to 40% faster
- Accuracy preserved — no compromises
Modular Sensor Choice
- Up to 8 gases — simultaneously
- Modular sensors — easy replacement
- Configuration — tailored to customer tasks
- Future upgrades — new sensors
Applications of the Rapidox SF6 6100 Pump Back
Usage scenarios
Commissioning
- SF6 quality verification after installation
- Analysis before first power-up
- Documentation for warranty
- Gas return — with no losses
Scheduled maintenance
- Regular condition monitoring
- Diagnosis of equipment aging
- Control of decomposition products
- Minimizing refills
After an emergency shutdown
- Analysis of the causes of the failure
- Verification of gas condition
- Decision on replacement/restoration
- Savings on new gas
Environmental control
- SF6 emissions accounting
- Reporting for the Kyoto Protocol
- ISO 14001 certification
- Green energy
Advantages over Standard Analysis
Comparison of analysis methods
| Method | Gas loss | Time | Cost |
|---|---|---|---|
| Laboratory analysis | 100% | Days | High |
| Standard portable | 100% | Minutes | Medium |
| Pump Back | <1% | Minutes | Fast payback |
Economic impact
- SF6 cost — ~$100 per kg
- Loss during analysis — typically 2-5 kg
- Pump Back savings — $200-500 per analysis
- Payback — after 10-20 analyses
Applications
Equipment types
- High-voltage circuit breakers — 110kV, 220kV, 500kV
- Medium-voltage circuit breakers — 6kV, 10kV, 35kV
- Gas-insulated lines (GIL) — long-distance lines
- Transformers — with SF6 insulation
- Switchgear (GIS) — packaged substations
Industries
- Power industry — grid companies
- Industry — in-house substations
- Railways — traction substations
- Oil and gas — emergency power supply
- Metallurgy — major power consumers
Scope of Delivery
Standard scope of delivery
- Rapidox SF6 6100 Pump Back gas analyzer
- Built-in vacuum pump
- Rugged Peli case with wheels
- Lithium battery
- Charger (220V + car charger)
- 2-meter sampling hose
- Connection fittings
- User manual
Optional accessories
- Built-in printer — on-site printing
- Additional sensors — extended analysis
- Calibration gases — for verification
- Special fittings — for different equipment types
- PC software — data analysis
Multilingual Support
Supported languages
- Russian
- English
- Deutsch
- Français
- Español
- Others upon request
Localization
- Interface in the selected language
- Reports in the user's language
- Compliance with local standards
Calibration and Service
Calibration
- Interval — every 12 months
- Sensor service life — more than 5 years
- Modular replacement — by the user
- Accredited centers — worldwide
Technical support
- Warranty — from the manufacturer
- Training — operator certification
- Hotline — technical support
- Updates — via USB
Environmental Responsibility
Zero Emission Technology
The Rapidox SF6 6100 Pump Back is a zero-emission solution:
- Minimize SF6 emissions — reducing emissions
- Environmental protection — safeguarding the environment
- Regulatory compliance — meeting requirements
- Sustainable future — sustainable development
SF6 and Climate
- Global warming potential — 23,500 × CO2
- Atmospheric lifetime — 3,200 years
- Kyoto Protocol — emissions regulation
- EU F-Gas Regulation — restrictions in Europe
Why Choose the Rapidox SF6 6100 Pump Back?
For environmentally responsible companies
- Zero emission technology
- Kyoto Protocol compliance
- Emissions reporting
- Green certification
For budget savings
- Minimizing SF6 purchases
- Fast payback
- Reduced operating costs
- Automation — less labor
For measurement quality
- Cambridge Sensotec quality
- Full automation
- Built-in CIGRE/IEC tests
- Modular sensors
Documents and Standards
Technical documentation
Standards
- IEC 60480 — Guide for used SF6
- IEC 62271 — High-voltage equipment
- CIGRE — SF6 recommendations
- CE — European conformity
Comparison with the Rapidox SF6 6100 Standard
| Characteristic | SF6 6100 Standard | SF6 6100 Pump Back |
|---|---|---|
| Gas return | No | Yes |
| Weight | 8.5 kg | 21 kg |
| Automation | Full | Full + pump |
| SF6 emissions | 100% of sample | <1% |
| Cost | Base | Premium |
| Application | General analysis | Gas savings |
Model Selection
Choose Standard if:
- You have a limited budget
- You need lightweight portability
- You are analyzing new installations
- You have no gas-return requirements
Choose Pump Back if:
- You perform frequent equipment analysis
- SF6 gas is expensive for you
- You have environmental requirements
- Gas savings are important to you
Technical specifications
| display | 7-inch touchscreen TFT display (180 mm) |
| humidity | -60°C to +20°C dew point |
| purity | 0 - 100% SF6 with ±0.5% accuracy |
| decomposition | SO2, H2S and other gases up to 1000 ppm |
| pump | Built-in vacuum pump |
| battery | Lithium battery, up to 8 hours of operation |
| protection | IP66, rugged Peli case |
| weight | 21 kg including wheels |
| dimensions | 500 x 400 x 250 mm |
| languages | Multilingual interface |
| connectivity | USB, Ethernet |
Applications
Manufacturer
Cambridge Sensotec
Fully automatic SF6 gas analyzer with gas return function to minimize emissions
Key specifications
- display
- 7-inch touchscreen TFT display (180 mm)
- humidity
- -60°C to +20°C dew point
- purity
- 0 - 100% SF6 with ±0.5% accuracy
- decomposition
- SO2, H2S and other gases up to 1000 ppm
- pump
- Built-in vacuum pump
Official supplier in Kazakhstan
Related products
Rapidox SF6 6100 - Portable SF6 Gas Analyzer
Portable gas analyzer for measuring moisture, purity and decomposition products of sulfur hexafluori...
Cambridge Sensotec
Rapidox 6100 C4-FN & C5-FK Multi-Gas Pumpback - Multi-Gas Analyzer for Eco-Friendly Gases
Fully automatic zero-emission multi-gas analyzer for C4-FN (Novec 4710) and C5-FK (Novec 5110) gas m...
Cambridge Sensotec
Need advice?
Our specialists will help you choose the optimal Rapidox SF6 6100 Pump Back - Gas Analyzer with Gas Return configuration for your equipment.
Related articles
All articles →Transformer DGA at CHP: What to Add Beyond Oil Chromatography
Dissolved gas analysis (DGA) is the gold standard for transformer diagnosis but not the only tool. Companion methods at CHP plants: cooling vibration, PD ultrasound, SF₆ and O₂ on adjacent switchgear.
Integrated Monitoring of CHP Transformer Bays: Rapidox, Vibration and Ultrasound
A CHP transformer bay is transformer, breakers, cooling and switchgear in one reliability loop. How to unify Rapidox (SF₆, O₂, Clean Air), Bently on oil pumps and SDT for partial discharges in one procedure.
Clean Air and Oxygen in SF₆-Free Switchgear: Monitoring at CHP During the SF₆ Transition
New dry-air (Clean Air) switchgear at CHP plants needs O₂, humidity and purity control. Rapidox 6100 Clean Air Pumpback for mixed SF₆ and SF₆-free fleets.
Oxygen Depletion in Enclosed MV Switchgear: O₂ and SF₆ Monitoring at CHP Substations
SF₆ leaks in enclosed switchgear displace oxygen below safe levels with no smell or visible warning. How to combine SF₆ and O₂ monitoring with Rapidox at combined heat and power substations.
Vibration Monitoring of Power Transformer Cooling Auxiliaries at CHP Plants
Oil pumps, radiator fans and water-cooling pumps on step-up transformers are a hidden CHP outage source. Bently Nevada 3500/42M, Orbit DCM and 1900/65A for transformer yard auxiliaries.
How to Test SF6 Gas Quality at a Substation: Step-by-Step Guide
Moisture, decomposition products and pressure loss in HV breakers and GIS — what to measure, IEC limits and how Rapidox analyzers sample SF6 without venting the compartment.