LUBExpert Case: Greasing a Cement-Plant Fan Exposed Bearing Failure Early
Case studyJuly 22, 2026

LUBExpert Case: Greasing a Cement-Plant Fan Exposed Bearing Failure Early

SDT cement-plant case: calendar greasing dosed 50 g every two weeks. LUBExpert Static cut dose to ~16/14 g and, with rising friction plus vibration, caught cooling-fan bearing failure before unplanned downtime.

LUBExpert lubrication data

Source. SDT Ultrasound case by Torki and vibration analyst Khaled Salman Almarwany — cooling-fan bearings at a cement plant with LUBExpert Static + vibration cross-check.

Before: calendar grease

50 g every two weeks on DE and NDE — no friction feedback. Classic path to over-greasing and missed early defects.

After: LUBExpert Static

With LUBExpert, the last successful task used about 16 g (DE) and 14.4 g (NDE).

DE grease plot — friction up

DE: friction rose after grease — over-lube or damaged bearing.

NDE grease plot — success

NDE: friction dropped, yet LUBExpert still flagged suspected bearing failure.

Vibration confirmation

Spectra showed mechanical looseness. Bearings were replaced on a planned shutdown. Overall RMS fell from 8.2 to 2.7. Four days later, new bearings were greased successfully with the same LUBExpert.

Vibration before replacement

Vibration after replacement

Successful post-replacement grease

Takeaway

Ultrasound cuts grease use and catches the moment when grease no longer helps — repair is required. Pair lubrication techs with vibration analysts. See grease savings. KEG TRKLUBExpert demo.