Supply in Kazakhstan
KEG TRK supplies measurement instrumentation solutions (Teplopribor) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.
Key features
Applications and resources
Industry solutions, landing pages and articles about Multi-Zone Resistance Thermometers
Where it is used
Typical tasks
- Chemical industry
- Oil and gas industry
- Power generation
- Scientific research
Description
Multi-zone resistance thermometers are designed for precise temperature measurement at multiple points along the sensor length.
Technical specifications
- Sensing element type: platinum (TSP)
- Number of zones: up to 6
- Measurement range: from -200 to +600 C
- Protection rating: IP65
Applications
- Temperature profile control in reactors
- Monitoring temperature distribution
- Scientific research
- Processes with uneven heating
Where it fits and how to choose
A multi-zone resistance thermometer places up to six platinum sensing elements in one protective tube, so a single sensor shows a temperature profile along its length: over the height of a chemical reactor, a distillation column or a tall tank where the product stratifies by temperature. The range per the card is -200 to +600°C. Compared with a multi-zone thermocouple (multi-zone thermocouples) the limit is lower, but the measurement is more stable and accurate in the moderate range and needs no cold-junction compensation. Compared with a set of single thermometers (ТСМ/ТСП-0193) one opening in the vessel and one installation are needed. The position of the zones is fixed at manufacture, so it is defined in advance from the process scheme.
What to include in an order
For selection please specify: the number of zones (up to 6 per the card) and the position of each zone from the end of the working part or from the mounting flange; the nominal static characteristic (for example Pt100) and tolerance class; the wiring scheme of each zone (2, 3 or 4 wires); the overall length, diameter and material of the protective tube; the mounting method; the head with a terminal block and IP65 protection, or transmitters; the number of channels of the secondary instrument; explosion protection.
Limits
The number of wires grows with the number of zones: six zones in a four-wire scheme give twenty-four conductors, so for a thin tube three- or two-wire schemes or transmitters in the head are used. The position of the zones cannot be changed after manufacture, and when one zone fails the whole sensor is usually replaced. Heat can be conducted away along the long tube, so the readings of the zones near the flange should be checked for deviation from the medium. For a single point a multi-zone design is excessive.
Related
For hot furnaces and thermoelements above +600°C: multi-zone thermocouples. For a single point: ТСМ/ТСП-0193. For a ready thermometer with a lead: resistance thermometer sets. Connection: internal extension cable and SHR connector. The whole section: Measuring instruments.
Technical specifications
| Sensing element type | platinum (TSP) |
| Number of zones | up to 6 |
| Protection rating | IP65 |
Applications
More by industry
Certificates and approvals
- Russian State Register of Measuring Instruments
Manufacturer
Teplopribor
Resistance thermometers for temperature measurement at multiple points along the length
Key specifications
- Sensing element type
- platinum (TSP)
- Number of zones
- up to 6
- Protection rating
- IP65
Official supplier in Kazakhstan
Need advice?
Our specialists will help you choose the optimal Multi-Zone Resistance Thermometers configuration for your equipment.