Supply in Kazakhstan
KEG TRK supplies measurement instrumentation solutions (Teplopribor) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.
Key features
Applications and resources
Industry solutions, landing pages and articles about SHR Connector for Wire Connections
Where it is used
Typical tasks
- Thermocouple connections
- RTD connections
- Laboratories
Description
The SHR connector is designed for connecting wires from thermocouples and resistance thermometers to measuring instruments. It provides a reliable electrical connection.
Technical specifications
- Connector type: SHR (pin/socket)
- Number of contacts: 2-4
- Housing material: metal or plastic
- Protection rating: IP54
- Minimal thermal EMF: for precise measurements
Where it fits and how to choose
The SHR connector builds the electrical circuit of a temperature sensor from separate parts: it joins the wires of a thermocouple or a resistance thermometer with the cable and the measuring instrument and lets you disconnect the sensor without cutting the wire. This is convenient when the sensor must be removed for verification, replaced or moved while the line to the instrument stays. Per the card the connector type is pin and socket, the number of contacts is 2 to 4, the housing is metal or plastic, protection is IP54 and the marking is 1ExiaIICT6 (intrinsically safe circuit). The number of contacts matches the sensor scheme: two for a thermocouple and a two-wire resistance thermometer, three and four for three- and four-wire ones. In a thermocouple circuit the stated minimum thermo-EMF is essential: the contacts must not create a parasitic voltage.
What to include in an order
For selection please specify: the number of contacts (2, 3 or 4) according to the sensor scheme; the circuit type (thermocouple or resistance thermometer) and the thermocouple type; the housing material (metal or plastic); the pin and socket pair or only one of them; the cable and sensor the connector works with, for example the internal extension cable or the external extension cable; the hazardous zone and marking.
Limits
Any connector adds a risk point: dirt, oxidation and a loose contact increase resistance, and for a thermocouple signal of millivolts they disturb the measurement. IP54 protection is not designed for immersion or prolonged exposure to water. Suitability in a specific zone is checked together with the cable, sensor and instrument by their intrinsic safety parameters, and the choice of metal or plastic housing is confirmed by the marking of the specific product. The connector does not measure temperature itself and does not replace a cable.
Related
Cables for the connector: internal extension cable (inside hazardous areas) and external extension cable (outside zones). For detachable connection of a probe: contact holder. Sensors: TXA/TXK/TZhK/TNN thermocouples and ТСМ/ТСП-0193. Exia marking: Ex marking explained: how to decode ATEX, IECEx and TR CU 012. The whole section: Measuring instruments.
Technical specifications
| Connector type | SHR (pin/socket) |
| Number of contacts | 2-4 |
| Housing material | metal or plastic |
| Protection rating | IP54 |
Applications
More by industry
Certificates and approvals
- Explosion protection 1ExiaIICT6
Manufacturer
Teplopribor
SHR connector for connecting thermocouples and resistance thermometers
Key specifications
- Connector type
- SHR (pin/socket)
- Number of contacts
- 2-4
- Housing material
- metal or plastic
- Protection rating
- IP54
Official supplier in Kazakhstan
Related products

Fittings for Contact Holder Mounting
Fittings for mounting a contact holder on a tank
- flanged or threaded
- stainless steel

External Extension Cable
External extension cable for use outside hazardous areas
- thermocouple or RTD
- PVC, rubber

Internal Extension Cable
Internal extension cable for connecting sensors to measuring instruments
- thermocouple or RTD
- PVC, rubber
Need advice?
Our specialists will help you choose the optimal SHR Connector for Wire Connections configuration for your equipment.