Supply in Kazakhstan
KEG TRK supplies measurement instrumentation solutions (Teplopribor) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.
Key features
Applications and resources
Industry solutions, landing pages and articles about Thermocouples TXA/TXK/TZhK/TNN
Typical tasks
- Oil and gas industry
- Chemical industry
- Metallurgy
- Power generation
Description
TXA (chromel-alumel), TXK (chromel-copel), TZhK (iron-constantan) and TNN (nicrosil-nisil) thermocouples are designed for temperature measurement in various process applications.
Technical specifications
- Thermocouple type: TXA (K-type), TXK (L-type), TZhK (J-type), TNN (N-type)
- TXA measurement range: from -200 to +1300 C
- TXK measurement range: from -200 to +800 C
- Tolerance class: 1, 2, 3
- Protection rating: IP54, IP65
Design versions
- Single and dual thermocouples
- Working part length from 60 to 2000 mm
- Various connection options
- Sets with extension wires
Where it fits and how to choose
A thermocouple measures temperature through thermo-EMF: two dissimilar electrodes are joined at the measuring junction, and the voltage depends on the temperature difference between the measuring junction and the free ends. The secondary instrument must therefore compensate the temperature of the free ends, and extension wires must be of the same type as the thermocouple itself. This card covers four types. TXA (chromel-alumel, type K) is the most universal with the widest range, up to +1300°C. TXK (chromel-copel, type L) works up to +800°C and gives more millivolts per degree, which helps at moderate temperatures. TNN (nicrosil-nisil, type N) was developed as a more stable alternative to TXA for long operation at high temperature, while TZhK (iron-constantan, type J) is limited by oxidation of the iron electrode; the upper temperatures for TZhK and TNN are confirmed at order. Above 1300°C platinum-rhodium TPP/TPR thermocouples are used, and for more accurate measurement in a moderate range ТСМ/ТСП-0193 resistance thermometers.
What to include in an order
For selection please specify: the thermocouple type, or the conditions to choose it by (medium, atmosphere, range); the working and maximum temperature; the tolerance class (1, 2 or 3); single or double design; the length of the working part (60 to 2000 mm per the card) and the overall length; the material and diameter of the protective sheath; the mounting method (fitting, flange, movable); the protection rating IP54 or IP65; explosion protection; the length of extension wires and the type of instrument the thermocouple connects to.
Limits
The error of a thermocouple is set by its tolerance class and by drift in service, and at high temperature and in an aggressive atmosphere drift grows with time. Circuit errors (wrong extension type, no cold-junction compensation, parasitic thermo-EMF in connectors) often give a larger error than the thermocouple itself. The verification interval of up to 5 years from the card applies to normal conditions; at high temperature and in an aggressive medium, checks are made more often. If a 4-20 mA output is needed, see thermocouples with a standardized output signal.
Related
Nearby temperature sensors: TPP/TPR thermocouples (high temperatures), thermocouples with a standardized output signal (4-20 mA output), thermocouples for verification without removal (verification without removal), multi-zone thermocouples (profile along the length). For connection internal extension cable and SHR connector will help. How bearing and winding temperatures enter equipment protection is described in the article API 670 turbine vibration protection system. The whole section: Measuring instruments.
Technical specifications
| Thermocouple type | TXA (K-type), TXK (L-type), TZhK (J-type), TNN (N-type) |
| Tolerance class | 1, 2, 3 |
| Protection rating | IP54, IP65 |
Applications
Certificates and approvals
- Russian State Register of Measuring Instruments
Manufacturer
Teplopribor
Thermocouples of various types for temperature measurement over a wide range
Key specifications
- Thermocouple type
- TXA (K-type), TXK (L-type), TZhK (J-type), TNN (N-type)
- Tolerance class
- 1, 2, 3
- Protection rating
- IP54, IP65
Official supplier in Kazakhstan
Need advice?
Our specialists will help you choose the optimal Thermocouples TXA/TXK/TZhK/TNN configuration for your equipment.