Gas turbine monitoring
Gas turbine and GTU vibration protection: Bently Nevada 3500 and Orbit 60, 3300 XL probes, System 1 — rotor, axial position and auxiliaries. KEG TRK, Kazakhstan.

Gas turbines: API 670 protection
Industrial gas turbines need continuous rotor protection. On combined-cycle plants and compressor stations in Kazakhstan, an unplanned GTU trip hits output and hot-section repair schedules.
KEG TRK designs and commissions Bently Nevada monitoring: probes, racks, DCS and System 1 integration.
Bently Nevada on a gas turbine
- Radial vibration and axial position with 3500 or Orbit 60
- 3300 XL Proximity sensors and Keyphasor
- Auxiliaries: lube pumps and cooling fans — see power pumps
Olympus — hot-section RVI and thickness
On GTU outages:
- IPLEX — combustors, blades and hot path (IPLEX One, IPLEX NX, IPLEX TX II); practice — RVI of turbines and heat exchangers
- 39DL PLUS — balance-of-plant piping thickness (catalog)
Industry overview: power generation vibration.
Bently Nevada 3500, System 1, SDT ultrasound, Olympus and Ion Science — SF6/VOC for turbines, generators and balance-of-plant

Orbit 60 Series — Next-Generation Monitoring System
Next-generation machinery protection platform with advanced cybersecurity and high channel density

3500/42M Proximitor/Seismic Monitor
3500/42M Proximitor/Seismic Monitor: 4 channels for proximity and seismic sensors, vibration and position, 4–20 mA outputs

3300 XL Series — Eddy-Current Proximity Transducer System
3300 XL eddy-current proximity probes for radial vibration, axial position and gap

System 1 — condition monitoring platform
Flagship Bently Nevada condition monitoring and diagnostics platform

Olympus IPLEX One — 10th-generation videoscope
The 10th generation of Olympus (Evident) IPLEX videoscopes: Plus, Expert and Prime tiers on one hardware platform, Swoptix optics without withdrawing the probe, 3DAssist, 10.1" 1100-nit tablet, four light sources, up to 360 min runtime.

Olympus IPLEX NX — flagship industrial videoscope
Flagship Olympus (Evident) videoscope: laser illumination up to 4 times brighter, stereo measurement and 3D defect modelling, 8.4" touchscreen, Ø4.0–6.2 mm probes up to 7.5 m, articulation up to 180°.

Olympus 39DL PLUS — ultrasonic thickness gauge
General-purpose Olympus (Evident) ultrasonic thickness gauge, successor to the 38DL PLUS: 0.08–635 mm, up to 60 Hz update, single and dual element transducers, THRU-COAT, Echo-to-Echo, B-scan, up to 792,832 readings, IP67, 0.83 kg.

Ion Science SF6 Leakmate — portable SF6 leak detector
Simple portable SF6 leak detector with a high voltage ionisation sensor: sensitivity 1×10⁻⁶ mbar·l/s, response about 1 s, 355 mm flexible probe, LED bar graph and an audio tone that follows leak size.

Ion Science Tiger XT — handheld PID detector for volatile organic compounds
Intrinsically safe Ion Science photoionisation detector for over 750 volatile organic compounds: 1 ppb to 20,000 ppm, T90 under 2 s, Fence Electrode technology against humidity and contamination, up to 24 h runtime and 120,000 logged readings.
SDT for gas turbine monitoring monitoring
SDT Ultrasound instruments deliver full acoustic condition monitoring in dusty, noisy plants
Bently Nevada — vibration diagnostics
Permanent and distributed systems for critical mining assets

Orbit 60 Series — Next-Generation Monitoring System
Next-generation machinery protection platform with advanced cybersecurity and high channel density

3500/42M Proximitor/Seismic Monitor
3500/42M Proximitor/Seismic Monitor: 4 channels for proximity and seismic sensors, vibration and position, 4–20 mA outputs

3300 XL Series — Eddy-Current Proximity Transducer System
3300 XL eddy-current proximity probes for radial vibration, axial position and gap

System 1 — condition monitoring platform
Flagship Bently Nevada condition monitoring and diagnostics platform
Olympus — thickness gauging and videoscopes
When vibration finds a symptom, Olympus confirms metal, weld or internal cavity condition

Olympus 39DL PLUS — ultrasonic thickness gauge
General-purpose Olympus (Evident) ultrasonic thickness gauge, successor to the 38DL PLUS: 0.08–635 mm, up to 60 Hz update, single and dual element transducers, THRU-COAT, Echo-to-Echo, B-scan, up to 792,832 readings, IP67, 0.83 kg.

Olympus IPLEX One — 10th-generation videoscope
The 10th generation of Olympus (Evident) IPLEX videoscopes: Plus, Expert and Prime tiers on one hardware platform, Swoptix optics without withdrawing the probe, 3DAssist, 10.1" 1100-nit tablet, four light sources, up to 360 min runtime.

Olympus IPLEX NX — flagship industrial videoscope
Flagship Olympus (Evident) videoscope: laser illumination up to 4 times brighter, stereo measurement and 3D defect modelling, 8.4" touchscreen, Ø4.0–6.2 mm probes up to 7.5 m, articulation up to 180°.

Olympus IPLEX TX II — ultra-thin videoscope
Ultra-thin Olympus (Evident) videoscope: Ø2.2 mm flexible probe 1.2 m long with 135° articulation, or a Ø1.8 mm rigid probe. Image on a 10.1" tablet, 3–80 mm depth of field, probe usable underwater to 1.2 m.
Ion Science — SF6, VOC and industrial leaks
Portable and fixed detectors for SF6 at substations, VOC on chemical sites and refrigerant leaks in HVAC

Ion Science SF6 Leakmate — portable SF6 leak detector
Simple portable SF6 leak detector with a high voltage ionisation sensor: sensitivity 1×10⁻⁶ mbar·l/s, response about 1 s, 355 mm flexible probe, LED bar graph and an audio tone that follows leak size.

Ion Science SF6 LeakCheck P1 XTL — SF6 leak detector
Wireless SF6 and C4-FN leak detector on Negative Ion Capture technology: sensitivity to 1×10⁻⁸ cc/s (0.1 ppm), response about 0.5 s, ready at switch-on and no loss of sensitivity even at 100 % SF6.

Ion Science Tiger XT — handheld PID detector for volatile organic compounds
Intrinsically safe Ion Science photoionisation detector for over 750 volatile organic compounds: 1 ppb to 20,000 ppm, T90 under 2 s, Fence Electrode technology against humidity and contamination, up to 24 h runtime and 120,000 logged readings.
Solutions and resources
Products, related applications and articles for Gas turbine monitoring
Recommended products
Related applications
Useful articles
- RVI of turbines and heat exchangers: which IPLEX you need
- Which IPLEX videoscope to choose: One, NX, GX/GT, GAir or TX II
- Corrosion monitoring of pipes and vessels at power plants and refineries
- Case Study: 12-Month PdM Rollout at a Mine and CHP — Artesis, Bently and SDT
- Integrated PdM on One Site: Artesis + Bently Nevada + SDT
- 3500/42M Module on CHP Auxiliary Equipment — Bently Nevada
FAQ: Gas turbine monitoring monitoring
Need advice?
Our specialists will help you choose the optimal Gas turbine monitoring configuration for your equipment.