Orbit 60 Series

(Latest generation)

Orbit 60 Series

Description: Next-generation distributed monitoring with flexible I/O, System 1 connectivity and API 670 alignment for power and process industries.

Key features:

  • 4- and 6-channel input modules, 102.4 kHz sampling on dynamic inputs
  • Any dynamic channel can be used as a Keyphasor input
  • SIL 2 version available
  • Redundant PPM processing modules and power
  • Separate configuration (SIM) and condition monitoring (CMM) modules; the CMM is listen-only
  • Electromechanical and solid-state relays
  • Two chassis joined by a 60R/BRG01 Bridge module

Part number summary table

No.Module
60R/SIM01SIM
60R/PPM01PPM
60R/CMM01CMM
60R/CGW01Comm Gateway
60R/BRG01Bridge
60R/PIM01/02PIM
60R/INP01–INP12Input Modules
60R/REC01, 60R/RLY01, 60R/RLY02Output Modules

Chassis:

  • 19-inch 3U chassis: operating temperature −30 to +70 °C
  • 19-inch 6U chassis: operating temperature −30 to +65 °C

Frequently asked questions

Is it worth switching from 3500 Series to Orbit 60 if the current system still works?

If a 3500 system meets your needs, there is no urgent need to replace it: 3500 Series remains supported. Compared with the 3500, Orbit 60 offers a compact 3U chassis (4 or more per cabinet instead of 2–3 6U racks), hot-swapping of all modules, 3200+ lines of spectral resolution instead of 800, Keyphasor input on any dynamic channel, and a PAV module that covers about 90% of typical inputs. Switching makes sense when expanding a system or starting a new project.

Can existing 3300 XL sensors be used with Orbit 60?

Yes. The Orbit 60 dynamic input modules (PAV, PAS, PAA, PAD, PVT) and the KPH Keyphasor module accept 3-wire Proximitors, including 3300 XL. When upgrading, the sensors and cables on the machine can stay; the chassis and modules are replaced. For existing Velomitor sensors, Bently Nevada recommends the PAV module.

How does Orbit 60 handle cyber security?

Configuration and condition monitoring are separated into different modules. The SIM handles configuration: changes are locked with a RUN/PROG key, communications are TLS-encrypted and firmware is signed. The CMM passes data to System 1 over the business network and only listens to system data, with no ability to write. The modules are designed to IEC 62443-4-2.

How many channels does an Orbit 60 system support?

Dynamic input modules have 4 channels each; temperature and PVD modules have 6. The total channel count depends on the chassis contents and on the load of the PPM processing modules: Orbit Studio calculates utilization and warns at 90%, after which more PPMs are added. The 60R/BRG01 Bridge module joins up to two chassis into one system.

Documentation

Official manufacturer PDF documents. Key specifications are also published on this page.