Non-destructive testing and ultrasonic thickness gauges

Thickness gauges, flaw detectors, phased-array systems, eddy-current instruments and bond testers — Olympus/Evident line. Supply and support in Kazakhstan by KEG TRK.

Ultrasonic thickness gauges

27MG, 38DL PLUS, 39DL PLUS, 45MG, 72DL PLUS, Magna-Mike 8600 and 35RDC — corrosion, coatings, Hall-effect and composite damage.

Thickness & coating gauges →
Olympus 27MG — ultrasonic corrosion thickness gauge
Olympus

Olympus 27MG — ultrasonic corrosion thickness gauge

Simple Olympus (Evident) ultrasonic corrosion gauge: 0.5–635 mm, 2.25–10 MHz dual element transducers, Min/Max mode at 20 readings per second, 150 h on three AA batteries, IP65, 340 g.

  • 0.50–635 mm (depends on material and conditions)
  • 0.1 mm or 0.01 mm
Цена по запросуПодробнее
Olympus 35RDC — composite damage checker
Olympus

Olympus 35RDC — composite damage checker

Simple go/no-go Olympus (Evident) ultrasonic instrument for finding hidden impact damage in solid laminate aircraft composites: 0.63–22.8 mm, 5 MHz transducer, 150 h on three AA batteries, IP65, 240 g.

  • impact damage in solid laminate aircraft composites
  • 0.63–22.8 mm
Цена по запросуПодробнее
Снято с производства
Olympus 38DL PLUS — ultrasonic thickness gauge (replaced by 39DL PLUS)
Olympus

Olympus 38DL PLUS — ultrasonic thickness gauge (replaced by 39DL PLUS)

Previous-generation Olympus general-purpose ultrasonic thickness gauge. The manufacturer (Evident) redirects the 38DL PLUS page to its successor, the 39DL PLUS, which we offer for new supply.

  • replaced by the 39DL PLUS
  • Olympus (Evident) 39DL PLUS
Цена по запросуПодробнее
Olympus 39DL PLUS — ultrasonic thickness gauge
Olympus

Olympus 39DL PLUS — ultrasonic thickness gauge

General-purpose Olympus (Evident) ultrasonic thickness gauge, successor to the 38DL PLUS: 0.08–635 mm, up to 60 Hz update, single and dual element transducers, THRU-COAT, Echo-to-Echo, B-scan, up to 792,832 readings, IP67, 0.83 kg.

  • 0.08–635 mm
  • 0.1 mm; 0.01 mm; 0.001 mm (option)
Цена по запросуПодробнее
Olympus 45MG — ultrasonic thickness gauge
Olympus

Olympus 45MG — ultrasonic thickness gauge

Olympus (Evident) ultrasonic thickness gauge: 0.08–635 mm, dual and single element transducers, Echo-to-Echo and THRU-COAT options for measuring through coatings, up to 475,000 readings, 3 AA batteries, IP67, 431 g.

  • 0.08–635 mm (depends on material and transducer)
  • 0.508–18.699 mm/µs
Цена по запросуПодробнее
Olympus 72DL PLUS — high-frequency ultrasonic thickness gauge
Olympus

Olympus 72DL PLUS — high-frequency ultrasonic thickness gauge

Precision Olympus (Evident) ultrasonic thickness gauge: standard (0.2–30 MHz) or high-frequency (20–125 MHz) version, up to 6 layers in one measurement, resolution to 0.25 µm, 7" touchscreen, up to 2 kHz, about 400,000 readings memory.

  • steel 0.20–635 mm; plastic 0.0127–25.4 mm
  • standard 0.2–30 MHz; HF 20–125 MHz (−3 dB)
Цена по запросуПодробнее
Olympus Magna-Mike 8600 — Hall effect thickness gauge
Olympus

Olympus Magna-Mike 8600 — Hall effect thickness gauge

Magnetic Olympus (Evident) thickness gauge for nonferrous materials: a Hall effect sensor measures the distance to a steel ball, disk or wire on the other side of the wall. 0.001 to 25.4 mm, 60 Hz, VGA display, data logger.

  • Hall effect, distance to target
  • 0.001–2.03 mm
Цена по запросуПодробнее

Ultrasonic flaw detectors

Portable EPOCH instruments for field weld and flaw inspection.

Phased-array systems

OmniScan PAUT platforms for advanced ultrasonic inspection.

Снято с производства
Olympus OmniScan MX2 — phased array flaw detector (previous generation)
Olympus

Olympus OmniScan MX2 — phased array flaw detector (previous generation)

Previous-generation modular Olympus phased array and conventional UT flaw detector. It is not in Evident's current lineup; for new supply we offer the OmniScan X3 or X4.

  • not in Evident's current lineup
  • OmniScan X3, OmniScan X4
Цена по запросуПодробнее
Olympus OmniScan SX — compact PA and UT flaw detector
Olympus

Olympus OmniScan SX — compact PA and UT flaw detector

Compact Olympus (Evident) flaw detector: SX PA with 16:64PR phased array and SX UT for conventional UT and TOFD. 8.4" display, up to 256 focal laws, at least 6 h runtime, 3.4 kg, IP66.

  • SX PA (16:64PR), SX UT
  • 1 PA connector, 2 UT LEMO 00 connectors
Цена по запросуПодробнее
Olympus OmniScan X3 — phased array flaw detector with TFM
Olympus

Olympus OmniScan X3 — phased array flaw detector with TFM

Olympus (Evident) phased array flaw detector with full matrix capture and TFM: X3 series (16:64PR, 16:128PR) and X3 64 (32:128PR, 64:128PR), up to 4 simultaneous TFM groups, 10.6" display, two hot-swap batteries, IP65.

  • X3: 16:64PR, 16:128PR; X3 64: 32:128PR, 64:128PR
  • PAUT, TOFD, TFM (MXU software)
Цена по запросуПодробнее
Olympus OmniScan X4 — next-generation phased array flaw detector
Olympus

Olympus OmniScan X4 — next-generation phased array flaw detector

Next-generation Olympus (Evident) phased array flaw detectors: five configurations from 16:64PR to 128:128PR, FMC/TFM/PCI/PWI, TFM images up to 1024 × 1024, 1 TB SSD, Wi-Fi 6E and Bluetooth 5.3, IP65, MIL-STD-810G.

  • 16:64PR, 16:128PR, 32:128PR, 64:128PR, 128:128PR
  • PAUT, TOFD, TFM; FMC/TFM/PCI/PWI on 64:128PR and 128:128PR
Цена по запросуПодробнее

Eddy current flaw detectors

NORTEC 600 for surface flaws, conductivity and coating thickness.

Bond testers

BondMaster 600 — pitch-catch, resonance and MIA for honeycomb and laminate composites.

Ultrasonic transducers

Dual-element and contact probes D790, D791, M112 and THRU-COAT for Olympus gauges.

NDT accessories

Couplant gel and calibration step wedges for thickness gauges and flaw detectors.