KEG TRK — Поставка промышленных решений в Казахстане
OlympusThickness Gages

Olympus 72DL PLUS — high-frequency ultrasonic thickness gauge

Precision Olympus (Evident) ultrasonic thickness gauge: standard (0.2–30 MHz) or high-frequency (20–125 MHz) version, up to 6 layers in one measurement, resolution to 0.25 µm, 7" touchscreen, up to 2 kHz, about 400,000 readings memory.

Olympus 72DL PLUS — high-frequency ultrasonic thickness gauge — Olympus
Olympus 72DL PLUS — high-frequency ultrasonic thickness gauge

Supply in Kazakhstan

KEG TRK supplies non-destructive testing solutions (Olympus) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.

Key features

Standard 0.2–30 MHz and high-frequency 20–125 MHz versions
Up to 6 layers in one measurement
Resolution to 0.001 mm (standard) and 0.25 µm (HF)
Steel 0.20–635 mm, plastic 0.0127–25.4 mm
Measurement rate up to 2 kHz (1–3 layers)
7" WVGA 800 × 480 touchscreen
2 GB memory: ~400,000 readings or 20,000 waveforms
IP65, about 8 h runtime

Industry solutions, landing pages and articles on Olympus 72DL PLUS — high-frequency ultrasonic thickness gauge

Typical tasks

  • Thin coatings and films
  • Multilayer plastic products and packaging
  • Thin-walled metal parts
  • Inline inspection at high measurement rates
  • Quality control laboratories

Overview

The 72DL PLUS is a precision ultrasonic thickness gauge from Olympus (now the Evident brand) for thin and multilayer products. It comes in two versions: standard at 0.2–30 MHz and high-frequency at 20–125 MHz, with resolution down to 0.25 µm.

It measures up to six layers in one measurement, and rates up to 2 kHz allow work directly on production lines. It is operated through a 7-inch touchscreen.

Olympus 72DL PLUS

Versions

Parameter Standard High-frequency
Transducer frequency 0.2–30 MHz 20–125 MHz
Resolution 0.1 / 0.01 / 0.001 mm 25 / 2.5 / 0.25 µm
Measurement rate (1–3 layers) up to 2 kHz up to 1 kHz

Technical specifications

Parameter Value
Range steel 0.20–635 mm; plastic 0.0127–25.4 mm
Layers up to 6
Display 7" WVGA 800 × 480, touchscreen
Memory 2 GB, ~400,000 readings or 20,000 waveforms
Power ~8 h
Protection IP65
Operating temperature −10 to +50 °C
Dimensions 238.8 × 172.7 × 86.4 mm
Weight 2.08 kg

Other thickness gauges

For corrosion and field work, see the 39DL PLUS and 45MG. Transducers: M112, D790.

What it is used for

The 72DL PLUS is for jobs where a standard corrosion gauge is not enough: thin walls and coatings, multilayer materials, inspection on a line. The manufacturer names, among others, multilayer automotive paint (up to six layers), plastic containers, thin-walled tubing, sheet metal and films, and aerospace coatings. In Kazakhstan industry that means quality control laboratories, packaging and pipe production, and inspection of coated parts.

How to use it in practice

  1. Choose the version: standard (0.2–30 MHz) for metal and plastic of ordinary thickness, high-frequency (20–125 MHz) for very thin layers.
  2. Select a transducer for the thickness range and set the number of layers (up to 6).
  3. Enter the sound velocity for each layer or calibrate on a sample.
  4. Measure: up to 2 kHz on the standard version with 1–3 layers, up to 1 kHz on the high-frequency version.
  5. Save the result to the 2 GB memory or transfer it over Wi-Fi, Bluetooth or USB; there is a foot switch input for line work.

Choosing between neighbouring models

Parameter 39DL PLUS 72DL PLUS Magna-Mike 8600
Principle ultrasound ultrasound Hall effect
Layers multilayer option up to 6 single wall
Minimum thickness steel from 0.08 mm plastic from 0.0127 mm, steel from 0.20 mm from 0.001 mm (depends on target)
Material metals and others metals, plastics, coatings non-magnetic
Weight 0.83 kg 2.08 kg 1.68 kg

What to prepare for an order

  • a list of materials and layers with the expected thickness of each;
  • the minimum thickness, which decides between the standard and high-frequency version;
  • conditions: on a line or in a laboratory, measurement speed;
  • how data will be exported (PC, network);
  • samples of known thickness for calibration.

Limits

  • The 2.08 kg weight and IP65 protection suit a laboratory or a line, not long inspection rounds.
  • The high-frequency version has a lower measurement rate than the standard one.
  • Each layer needs its own sound velocity; without it the result for that layer is wrong.

Related materials

Supply in Kazakhstan

KEG TRK supplies Olympus (Evident) thickness gauges, selects transducers for material and thickness, and trains staff. Price on request.

Manufacturer

Olympus

Thickness Gages

Precision Olympus (Evident) ultrasonic thickness gauge: standard (0.2–30 MHz) or high-frequency (20–125 MHz) version, up to 6 layers in one measurement, resolution to 0.25 µm, 7" touchscreen, up to 2 kHz, about 400,000 readings memory.

Key specifications

Range
steel 0.20–635 mm; plastic 0.0127–25.4 mm
Frequency
standard 0.2–30 MHz; HF 20–125 MHz (−3 dB)
Resolution (standard)
0.1 / 0.01 / 0.001 mm
Resolution (HF)
25 / 2.5 / 0.25 µm
Multilayer
up to 6 layers

Official supplier in Kazakhstan

Related products

Olympus 39DL PLUS — ultrasonic thickness gauge
Olympus

Olympus 39DL PLUS — ultrasonic thickness gauge

General-purpose Olympus (Evident) ultrasonic thickness gauge, successor to the 38DL PLUS: 0.08–635 mm, up to 60 Hz update, single and dual element transducers, THRU-COAT, Echo-to-Echo, B-scan, up to 792,832 readings, IP67, 0.83 kg.

  • 0.08–635 mm
  • 0.1 mm; 0.01 mm; 0.001 mm (option)
Price on requestLearn more
Olympus 45MG — ultrasonic thickness gauge
Olympus

Olympus 45MG — ultrasonic thickness gauge

Olympus (Evident) ultrasonic thickness gauge: 0.08–635 mm, dual and single element transducers, Echo-to-Echo and THRU-COAT options for measuring through coatings, up to 475,000 readings, 3 AA batteries, IP67, 431 g.

  • 0.08–635 mm (depends on material and transducer)
  • 0.508–18.699 mm/µs
Price on requestLearn more
Olympus M112 — 10 MHz contact transducer
OlympusM112

Olympus M112 — 10 MHz contact transducer

Olympus (Evident) Microscan single element contact transducer: 10 MHz, 6 mm (0.25 in.) element, straight (M112-SM) or right-angle (M112-RM) Microdot connector. For precision thickness gauging and flaw detection.

  • single element contact
  • 10 MHz
Price on requestLearn more
Olympus D790 — dual element transducer for thickness gauges
OlympusD790

Olympus D790 — dual element transducer for thickness gauges

Olympus (Evident) dual element transducer for corrosion gauging: 5 MHz, 11 mm tip, 1.0–508 mm in steel, −20 to +500 °C, straight connector, potted cable.

  • dual element
  • 5 MHz
Price on requestLearn more
Olympus Magna-Mike 8600 — Hall effect thickness gauge
Olympus

Olympus Magna-Mike 8600 — Hall effect thickness gauge

Magnetic Olympus (Evident) thickness gauge for nonferrous materials: a Hall effect sensor measures the distance to a steel ball, disk or wire on the other side of the wall. 0.001 to 25.4 mm, 60 Hz, VGA display, data logger.

  • Hall effect, distance to target
  • 0.001–2.03 mm
Price on requestLearn more
Olympus — step wedge for thickness gauge calibration
Olympus

Olympus — step wedge for thickness gauge calibration

Step wedge with known step thicknesses for calibrating Olympus (Evident) ultrasonic thickness gauges and flaw detectors for velocity and zero. Material and step set are chosen to match the inspected part.

Price on requestLearn more

Need advice?

Our specialists will help you choose the optimal Olympus 72DL PLUS — high-frequency ultrasonic thickness gauge configuration for your equipment.

Related articles

All articles →

Часто задаваемые вопросы