Supply in Kazakhstan
KEG TRK supplies non-destructive testing solutions (Olympus) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.
Key features
Applications and resources
Industry solutions, landing pages and articles on Olympus M112 — 10 MHz contact transducer
Where it is used
Typical tasks
- Precision metal thickness gauging in manufacturing
- Use with the 39DL PLUS, 72DL PLUS and 45MG with SE option
- Conventional UT flaw detection
Overview
The M112 is an Olympus (now Evident) Microscan single element contact transducer at 10 MHz with a 6 mm element. It is used for precision metal thickness gauging on smooth surfaces and for flaw detection.

Technical specifications
| Parameter | Value |
|---|---|
| Type | single element contact |
| Frequency | 10 MHz |
| Element | 6 mm (0.25 in.) |
| Connector | Microdot straight (SM) or right-angle (RM) |
| Part numbers | U8400035 (SM), U8400034 (RM) |
Applications
- Precision metal thickness gauging in manufacturing
- Use with the 39DL PLUS, 72DL PLUS and 45MG with SE option
- Conventional UT flaw detection
Related instruments
For corroded and hot surfaces: dual element D790 and D791. Gauges: 39DL PLUS, 72DL PLUS, 45MG.
What it is used for
The M112 is a 10 MHz contact single element transducer for precision thickness gauging of smooth metal parts: plate, sheet, machined items, and for conventional ultrasonic flaw detection. These are incoming inspection and quality control tasks at manufacturers, repair and service companies. For corroded pipes and vessels with a rough surface dual element transducers are used.
How to use it in practice
- Connect the transducer to a gauge that supports single element transducers: the 39DL PLUS, 72DL PLUS or the 45MG with the SE option.
- Prepare a smooth surface and apply couplant.
- Calibrate velocity and zero on two steps of a sample in the same material.
- Place the transducer perpendicular to the surface and press without tilting.
- Record the reading and repeat calibration when the material or temperature changes.
Choosing among neighbouring transducers
| Transducer | Type | Frequency | Range / purpose |
|---|---|---|---|
| M112 | contact single element | 10 MHz, 6 mm element | precision gauging of metals |
| V260-SM | single element (Sonopen) | 15 MHz, 2 mm tip | steel 0.5–10 mm (Evident catalog) |
| M2017 | single element | 20 MHz, 6.35 mm element | steel 0.5–12 mm, oxide layer |
| D790 | dual element | 5 MHz | corrosion, up to +500 °C |
What to prepare for an order
- the material and thickness range;
- the surface condition: smooth or rough;
- the inspection temperature (contact transducers up to about 50 °C);
- the gauge model and the SE option for the 45MG;
- the connector version: straight M112-SM or right-angle M112-RM.
Limits
- It is worse than dual element transducers at finding pits on a corroded surface.
- Contact transducers are not meant for hot surfaces: they are used up to about 50 °C.
- You need samples in the same material to calibrate velocity and zero.
Related materials
- Ultrasonic Thickness Gauge: How It Works and Its Limitations
- Which Olympus thickness gauge to choose: 27MG, 38DL, 39DL, 45MG or 72DL
- Sound Velocity in Materials: A Table for Thickness Gauging
- 39DL PLUS, 72DL PLUS, 45MG, D790; step wedge, couplant
- Olympus thickness gauges and selection wizard, NDT equipment catalog
Supply in Kazakhstan
KEG TRK supplies Olympus (Evident) transducers and thickness gauges and selects transducers for material, thickness and temperature. Price on request.
Technical specifications
| Type | single element contact |
| Frequency | 10 MHz |
| Element | 6 mm (0.25 in.) |
| Connector | Microdot straight (SM) or right-angle (RM) |
| Part numbers | U8400035 (SM), U8400034 (RM) |
Applications
More by industry
Manufacturer
Olympus
Olympus (Evident) Microscan single element contact transducer: 10 MHz, 6 mm (0.25 in.) element, straight (M112-SM) or right-angle (M112-RM) Microdot connector. For precision thickness gauging and flaw detection.
Key specifications
- Type
- single element contact
- Frequency
- 10 MHz
- Element
- 6 mm (0.25 in.)
- Connector
- Microdot straight (SM) or right-angle (RM)
- Part numbers
- U8400035 (SM), U8400034 (RM)
Official supplier in Kazakhstan
Related products

Olympus 72DL PLUS — high-frequency ultrasonic thickness gauge
Precision Olympus (Evident) ultrasonic thickness gauge: standard (0.2–30 MHz) or high-frequency (20–125 MHz) version, up to 6 layers in one measurement, resolution to 0.25 µm, 7" touchscreen, up to 2 kHz, about 400,000 readings memory.
- steel 0.20–635 mm; plastic 0.0127–25.4 mm
- standard 0.2–30 MHz; HF 20–125 MHz (−3 dB)

Olympus 39DL PLUS — ultrasonic thickness gauge
General-purpose Olympus (Evident) ultrasonic thickness gauge, successor to the 38DL PLUS: 0.08–635 mm, up to 60 Hz update, single and dual element transducers, THRU-COAT, Echo-to-Echo, B-scan, up to 792,832 readings, IP67, 0.83 kg.
- 0.08–635 mm
- 0.1 mm; 0.01 mm; 0.001 mm (option)

Olympus 45MG — ultrasonic thickness gauge
Olympus (Evident) ultrasonic thickness gauge: 0.08–635 mm, dual and single element transducers, Echo-to-Echo and THRU-COAT options for measuring through coatings, up to 475,000 readings, 3 AA batteries, IP67, 431 g.
- 0.08–635 mm (depends on material and transducer)
- 0.508–18.699 mm/µs

Olympus D790 — dual element transducer for thickness gauges
Olympus (Evident) dual element transducer for corrosion gauging: 5 MHz, 11 mm tip, 1.0–508 mm in steel, −20 to +500 °C, straight connector, potted cable.
- dual element
- 5 MHz

Olympus — step wedge for thickness gauge calibration
Step wedge with known step thicknesses for calibrating Olympus (Evident) ultrasonic thickness gauges and flaw detectors for velocity and zero. Material and step set are chosen to match the inspected part.

Olympus — ultrasonic couplant
Olympus (Evident) couplant for ultrasonic thickness gauging and flaw detection: it removes the air gap between transducer and surface, without which ultrasound does not enter the metal. The couplant type is chosen for surface, temperature and orientation.
Need advice?
Our specialists will help you choose the optimal Olympus M112 — 10 MHz contact transducer configuration for your equipment.
Related articles
All articles →Ultrasonic Thickness Gauge: How It Works and Its Limitations
How an ultrasonic thickness gauge calculates thickness from an echo, contact, delay line, immersion and dual element transducers, measurement modes, what affects accuracy and where the method fails.
Sound Velocity in Materials: A Table for Thickness Gauging
Longitudinal ultrasonic velocity in steels, aluminum, copper, cast iron and plastics per Evident data (m/s and in/µs). Why velocity is calibrated on a sample and how temperature affects it.

Which Olympus thickness gauge to choose: 27MG, 38DL, 39DL, 45MG or 72DL
Compare Olympus/Evident thickness gauges for corrosion, coatings and precision work — what fits power plants, refineries and mining sites