Supply in Kazakhstan
KEG TRK supplies non-destructive testing solutions (Olympus) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.
Key features
Applications and resources
Industry solutions, landing pages and articles on Olympus OmniScan SX — compact PA and UT flaw detector
Typical tasks
- Girth and longitudinal weld inspection
- TOFD inspection
- Corrosion mapping
- Work at height and in tight spaces where weight matters
Overview
The OmniScan SX is a compact Olympus (now Evident) flaw detector for phased array and conventional ultrasonic testing. It is lighter and simpler than the X3 and X4 and suits routine weld inspection, TOFD and corrosion mapping.
Two versions are available: SX PA with 16:64PR phased array and SX UT for conventional UT. Both include a conventional UT channel for pulse-echo, pitch-catch and TOFD.

Versions
| Version | Phased array | Conventional UT and TOFD |
|---|---|---|
| SX PA | 16:64PR | yes |
| SX UT | no | yes |
Technical specifications
| Parameter | Value |
|---|---|
| Connectors | 1 PA, 2 UT LEMO 00 |
| Focal laws | up to 256 |
| Display | 8.4" TFT 800 × 600, 600 cd/m² |
| Files | up to 300 MB, SDHC or USB |
| Power | Li-ion, ≥ 6 h |
| Protection | IP66 |
| Operating temperature | −10 to +45 °C |
| Dimensions | 267 × 208 × 94 mm |
| Weight | 3.4 kg |
Other instruments
For TFM and larger apertures: OmniScan X3 and OmniScan X4. Conventional UT: EPOCH 650.
What it is used for
The OmniScan SX covers typical phased array and conventional ultrasonic inspection when you want a lighter instrument: welds (including to ASME, API, AWS and EN requirements), TOFD, corrosion mapping, composites, and component inspection with angle and zero-degree beams. In Kazakhstan that means oil and gas sites, pipelines, vessels, metallurgical and power plants.
How to use it in practice
- Build an inspection plan in NDT SetupBuilder on a PC or on the instrument and transfer the setup to the SX.
- Choose the version: SX PA with 16:64PR phased array, or SX UT for conventional UT and TOFD only.
- Connect the probe and a scanner with an encoder, calibrate velocity, wedge and sensitivity.
- Scan the weld; for a curved longitudinal weld use ray tracing.
- Save the data to an SDHC card or USB drive and analyse it in OmniPC.
Choosing between neighbouring models
| Parameter | OmniScan SX | OmniScan X3 | OmniScan X4 | EPOCH 650 |
|---|---|---|---|---|
| Method | PA 16:64PR and UT / TOFD | PA, TOFD, TFM | PA, TOFD, TFM, PCI | conventional UT |
| Weight | 3.4 kg | 5.7 kg | 5.7–5.9 kg | 1.6 kg |
| Display | 8.4" | 10.6" | 10.6" | VGA |
| File | up to 300 MB | up to 25 GB | up to 25 GB | 100,000 IDs |
What to prepare for an order
- the material, thickness and type of weld;
- the procedure, codes and documentation requirements;
- SX PA or SX UT;
- probes, wedges and scanners;
- operator training and certification.
Limits
- Up to 256 focal laws: for TFM and larger apertures you need the X3 or X4.
- Maximum file size 300 MB.
- Independent work needs a procedure and a trained operator.
Related materials
- Thickness gauging, flaw detector or PAUT: which NDT tool you need on site
- Weld NDT at mining and metals plants: EPOCH or OmniScan
- Ultrasonic Flaw Detector: How It Works and What It Finds
- Non-Destructive Testing Methods: Types, What They Find, Where They Are Used
- OmniScan X3, OmniScan X4, EPOCH 650, EPOCH 6LT
- NDT equipment catalog
Supply in Kazakhstan
KEG TRK supplies Olympus (Evident) flaw detectors, probes and scanners, and trains staff. Price on request.
Technical specifications
| Models | SX PA (16:64PR), SX UT |
| Connectors | 1 PA connector, 2 UT LEMO 00 connectors |
| PA aperture | 16 elements of 64 |
| Focal laws | up to 256 |
| Display | 8.4" TFT, 800 × 600, 600 cd/m² |
| File size | up to 300 MB |
| Storage | SDHC or USB drive |
| Power | Li-ion, at least 6 h |
| Protection | IP66 |
| Operating temperature | −10 to +45 °C |
| Dimensions | 267 × 208 × 94 mm |
| Weight | 3.4 kg with battery |
Applications
Manufacturer
Olympus
Compact Olympus (Evident) flaw detector: SX PA with 16:64PR phased array and SX UT for conventional UT and TOFD. 8.4" display, up to 256 focal laws, at least 6 h runtime, 3.4 kg, IP66.
Key specifications
- Models
- SX PA (16:64PR), SX UT
- Connectors
- 1 PA connector, 2 UT LEMO 00 connectors
- PA aperture
- 16 elements of 64
- Focal laws
- up to 256
- Display
- 8.4" TFT, 800 × 600, 600 cd/m²
Official supplier in Kazakhstan
Related products

Olympus OmniScan X3 — phased array flaw detector with TFM
Olympus (Evident) phased array flaw detector with full matrix capture and TFM: X3 series (16:64PR, 16:128PR) and X3 64 (32:128PR, 64:128PR), up to 4 simultaneous TFM groups, 10.6" display, two hot-swap batteries, IP65.
- X3: 16:64PR, 16:128PR; X3 64: 32:128PR, 64:128PR
- PAUT, TOFD, TFM (MXU software)

Olympus OmniScan X4 — next-generation phased array flaw detector
Next-generation Olympus (Evident) phased array flaw detectors: five configurations from 16:64PR to 128:128PR, FMC/TFM/PCI/PWI, TFM images up to 1024 × 1024, 1 TB SSD, Wi-Fi 6E and Bluetooth 5.3, IP65, MIL-STD-810G.
- 16:64PR, 16:128PR, 32:128PR, 64:128PR, 128:128PR
- PAUT, TOFD, TFM; FMC/TFM/PCI/PWI on 64:128PR and 128:128PR

Olympus EPOCH 650 — ultrasonic flaw detector
Portable Olympus (Evident) ultrasonic flaw detector: tunable square-wave pulser up to 400 V, 0.2–26.5 MHz bandwidth, VGA display, DGS/AVG, DAC/TCG and AWS as standard, 100,000 IDs, 15–16 h runtime, IP67.
- 3.36–13,388 mm at 5900 m/s
- tunable square wave, 100/200/300/400 V

Olympus EPOCH 6LT — lightweight ultrasonic flaw detector
Lightweight Olympus (Evident) ultrasonic flaw detector, 890 g, for one-handed and rope access work: pulser up to 400 V, bandwidth up to 26.5 MHz, VGA display, 100,000 IDs, IP67.
- 4.31–6700 mm at 5900 m/s
- square wave, 100/200/300/400 V
Need advice?
Our specialists will help you choose the optimal Olympus OmniScan SX — compact PA and UT flaw detector configuration for your equipment.
Related articles
All articles →
Non-Destructive Testing Methods: Types, What They Find, Where They Are Used
The main NDT methods: visual (videoscopes), ultrasonic thickness gauging, flaw detection and PAUT, eddy current, magnetic particle, penetrant, radiography and acoustic emission.
Ultrasonic Flaw Detector: How It Works and What It Finds
The pulse-echo principle, how to read an A-scan, straight and angle beam transducers, which flaws a detector finds, velocity and zero calibration, reference blocks and the DAC curve.

Weld NDT at mining and metals plants: EPOCH or OmniScan
When a conventional EPOCH flaw detector is enough on GOK/metals sites — and when OmniScan PAUT is justified

Thickness gauging, flaw detector or PAUT: which NDT tool you need
When an Olympus thickness gauge is enough, when you need EPOCH, and when OmniScan PAUT is justified