Bently Nevada3500 Series3500/42M

3500/42M Proximitor/Seismic Monitor

3500/42M Proximitor/Seismic Monitor: 4 channels for proximity and seismic sensors, vibration and position, 4–20 mA outputs

3500/42M Proximitor/Seismic Monitor — Bently Nevada
3500/42M Proximitor/Seismic Monitor

Supply in Kazakhstan

KEG TRK supplies vibration monitoring and analysis solutions (Bently Nevada) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.

Key features

The most versatile 3500 monitor
Proximity probes, accelerometers and velocity sensors
Shaft absolute and circular acceptance regions
4–20 mA per channel
Operating temperature −30 to +65 °C

Industry solutions, landing pages and articles about 3500/42M Proximitor/Seismic Monitor

Description

The 3500/42M Proximitor/Seismic Monitor is a four-channel 3500 rack monitor that takes proximity and seismic transducers, measures vibration and position and compares them with setpoints. It is the main monitor for turbines, compressors and pumps that carry both shaft proximity probes and casing accelerometers.

Specifications (datasheet 143694)

Parameter Value
Channels 4 channels, programmed in pairs
Input type proximity and seismic transducers (accelerometers, velocity sensors)
Measurements radial vibration, thrust, eccentricity, differential expansion, REBAM, acceleration, velocity, shaft absolute
Outputs 4–20 mA per channel, buffered BNC outputs
Temperature −30 to +65 °C

Supply in Kazakhstan

KEG TRK supplies the 3500/42M and its I/O modules and helps with 3500 rack configuration and commissioning across Kazakhstan.

Manufacturer

Bently Nevada

3500/42M3500 Series

3500/42M Proximitor/Seismic Monitor: 4 channels for proximity and seismic sensors, vibration and position, 4–20 mA outputs

Key specifications

Channels
4 channels, programmed in pairs
Input type
proximity and seismic transducers (accelerometers, velocity sensors)
Measurements
radial vibration, thrust, eccentricity, differential expansion, REBAM, acceleration, velocity, shaft absolute
Outputs
4–20 mA per channel, buffered BNC outputs
Temperature
−30 to +65 °C

Official supplier in Kazakhstan

Need advice?

Our specialists will help you choose the optimal 3500/42M Proximitor/Seismic Monitor configuration for your equipment.

Related articles

All articles →
Case Study: 12-Month PdM Rollout at a Mine and CHP — Artesis, Bently and SDT
Case study

Case Study: 12-Month PdM Rollout at a Mine and CHP — Artesis, Bently and SDT

Typical holding scenario: SDT routes, Orbit DCM on conveyors, e-MCM on mills, e-PCM on DGS, IoT for management — timeline, metrics and lessons.

Integrated PdM on One Site: Artesis + Bently Nevada + SDT
Article

Integrated PdM on One Site: Artesis + Bently Nevada + SDT

Three KEG TRK pillars on one plant: Bently vibration on turbo-machinery, SDT ultrasound on routes, Artesis ESA on motors and generators — zone matrix, workflow and architecture.

Application

3500/42M Module on CHP Auxiliary Equipment — Bently Nevada

Combined heat and power auxiliary equipment: feed pumps, ID fans, FD fans, coal mills — applying Bently Nevada 3500/42M, DCS integration and how it differs from main turbine protection.

Integrated Monitoring of CHP Transformer Bays: Rapidox, Vibration and Ultrasound
Application

Integrated Monitoring of CHP Transformer Bays: Rapidox, Vibration and Ultrasound

A CHP transformer bay is transformer, breakers, cooling and switchgear in one reliability loop. How to unify Rapidox (SF₆, O₂, Clean Air), Bently on oil pumps and SDT for partial discharges in one procedure.

Predictive Maintenance of Metallurgy Gearboxes: Spectral Analysis — Bently Nevada
Application

Predictive Maintenance of Metallurgy Gearboxes: Spectral Analysis — Bently Nevada

Tooth wear, pitting and misalignment in rolling mill and metallurgical conveyor gearboxes — how Bently Nevada spectral analysis and System 1 detect faults weeks before failure.

Vibration Monitoring of Power Transformer Cooling Auxiliaries at CHP Plants
Application

Vibration Monitoring of Power Transformer Cooling Auxiliaries at CHP Plants

Oil pumps, radiator fans and water-cooling pumps on step-up transformers are a hidden CHP outage source. Bently Nevada 3500/42M, Orbit DCM and 1900/65A for transformer yard auxiliaries.