Ion ScienceSF6 LeakCheckSF6 LeakCheck P1 XTL

Ion Science SF6 LeakCheck P1 XTL — SF6 leak detector

Wireless SF6 and C4-FN leak detector on Negative Ion Capture technology: sensitivity to 1×10⁻⁸ cc/s (0.1 ppm), response about 0.5 s, ready at switch-on and no loss of sensitivity even at 100 % SF6.

Ion Science SF6 LeakCheck P1 XTL — SF6 leak detector — Ion Science
Ion Science SF6 LeakCheck P1 XTL — SF6 leak detector

Supply in Kazakhstan

KEG TRK supplies equipment diagnostics solutions (Ion Science) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.

Key features

Negative Ion Capture (NIC) technology, no drift at SF6 saturation
Two sensitivity levels — 1 ppm and 0.1 ppm
T90/T10 response about 0.5 s, no warm-up
750 g wireless handgun with 2.8" touch display
Vibration, audio and LED projection at the leak point
Self-diagnostics for flow, sensor, battery and electronics
Pre-calibrated replaceable SmartSensor

Industry solutions, landing pages and articles on Ion Science SF6 LeakCheck P1 XTL — SF6 leak detector

Typical tasks

  • Locating SF6 leaks on GIS and HV circuit breakers
  • Checking flanges, bushings and density monitors
  • Acceptance testing of new SF6 equipment
  • Tightness checks on C4-FN (g3) compartments
  • Routine substation surveys

Overview

The SF6 LeakCheck P1 XTL is an SF6 leak detector from the British company Ion Science. It pinpoints exactly where gas escapes on GIS, circuit breakers and current transformers: a flange, bushing, density monitor or weld.

The instrument consists of a wireless handgun probe and a console with a docking station. The operator runs the probe along joints, and the handgun shows the level on screen, vibrates, changes audio pitch and projects an LED light onto the leak point.

SF6 LeakCheck P1 XTL: wireless handgun in its charging console

Negative Ion Capture technology

Conventional SF6 leak detectors saturate when they hit a jet of pure gas and need time to recover. Ion Science's NIC sensor captures the negative ions formed by electronegative gas and keeps its sensitivity even at 100 % SF6. There is no drift, no warm-up and a response of about 0.5 seconds.

Sensitivity modes

Mode Leak rate Concentration Annual SF6 loss
Standard 1×10⁻⁷ cc/s 1 ppm 0.01 g/yr
High 1×10⁻⁸ cc/s 0.1 ppm 0.001 g/yr

High mode is used for acceptance of new equipment and very small leaks; standard mode suits routine surveys.

Ease of use

  • Wireless 750 g handgun — no cable in the way when working at height or in tight bays.
  • Three alarm types: vibration, audio with pitch tied to leak size, and an LED light spot at the leak.
  • Self-diagnostics: sample flow, sensor condition, battery, hardware faults.
  • SmartSensor: supplied pre-calibrated and replaced without sending the instrument for service.
  • Wheeled case for moving around the substation.

Technical specifications

Parameter Value
Technology Negative Ion Capture (NIC)
Gases SF6, C4-FN
Sensitivity 1×10⁻⁷ / 1×10⁻⁸ cc/s (1 / 0.1 ppm)
Response T90 / T10 about 0.5 s
Warm-up none
Display 2.8" touch screen
Power handgun LiPo with inductive charging; console LiFe; mains 85–265 V, 50/60 Hz
Handgun weight 750 g
Handgun dimensions 300 × 105 × 90 mm
Console dimensions 420 × 240 × 470 mm
Operating temperature 0 to +50 °C
Storage −10 to +60 °C

Choosing an Ion Science SF6 detector

Task Instrument
Pinpointing small leaks, acceptance testing, C4-FN SF6 LeakCheck P1 XTL
Simple checks on rounds, limited budget SF6 Leakmate
Continuous room concentration monitoring SF6 AreaCheck P2

Once a leak is found, gas quality in the apparatus is checked with a Rapidox SF6 6100 analyser.

Supply in Kazakhstan

KEG TRK is the official representative of Ion Science in Kazakhstan. We supply leak detectors, train staff and arrange calibration and service. Price on request.

Manufacturer

Ion Science

SF6 LeakCheck P1 XTLSF6 LeakCheck

Wireless SF6 and C4-FN leak detector on Negative Ion Capture technology: sensitivity to 1×10⁻⁸ cc/s (0.1 ppm), response about 0.5 s, ready at switch-on and no loss of sensitivity even at 100 % SF6.

Key specifications

Technology
Negative Ion Capture (NIC)
Gases detected
SF6, C4-FN
Sensitivity (standard)
1×10⁻⁷ cc/s, 1 ppm, 0.01 g/yr
Sensitivity (high)
1×10⁻⁸ cc/s, 0.1 ppm, 0.001 g/yr
Response T90 / T10
about 0.5 s

Official supplier in Kazakhstan

Need advice?

Our specialists will help you choose the optimal Ion Science SF6 LeakCheck P1 XTL — SF6 leak detector configuration for your equipment.

Related articles

All articles →

Часто задаваемые вопросы