Industry solutions, landing pages and articles about Rapidox SF6 6100 Portable — Portable SF6 Gas Analyser
Where it is used
Typical tasks
- GIS and SF6 circuit breakers
- SF6 current and voltage transformers
- Gas checks after filling and reclaim
- Incoming inspection of SF6 cylinders
- Mobile substation crews
Documentation
Official manufacturer PDF documents. Key specifications are also published on this page.
Need a price with delivery in Kazakhstan? We will prepare a quotation for your task.
Premium portable Rapidox SF6 6100 for on-site quality control of sulfur hexafluoride insulation.
Overview
The Rapidox SF6 6100 Portable is a portable analyser from the British company Cambridge Sensotec for monitoring SF6 quality in medium and high voltage gas-insulated equipment. It is the lightest field model in the range: 8.5 kg including the case.
The instrument measures SF6 purity, moisture and decomposition products. The configuration is modular, with up to eight gases per instrument. Compartment gas pressure is logged together with the results.
Why analyse SF6
Arcing and partial discharge break SF6 down. Decomposition products are toxic and attack insulation, and moisture lowers dielectric strength. Regular analysis finds internal defects before failure, confirms gas quality after filling and helps assess the hazard before a compartment is opened.
SF6 is a greenhouse gas and must not be vented, so the sample from the Rapidox SF6 6100 Portable is collected in a bag.
How a measurement works
- Connect with self-sealing tongue-and-groove couplings compatible with major equipment brands.
- Gas flows through the analyser on compartment pressure, up to 10 bar. For sources at atmospheric pressure, an optional pump is fitted.
- All gases are measured and logged simultaneously; a stable reading takes a few minutes.
- The spent sample goes to the gas recovery bag.
- Results are printed on the built-in thermal printer and exported to a USB stick.
Sensors and ranges
| Parameter | Range | Accuracy | Sensor type | Calibration | Life span |
|---|---|---|---|---|---|
| SF6 | 0–100 % | ±0.5 % | IR | 12 months | over 5 years |
| H₂O (dew point) | -60 to +20 °Cdp (10–24,000 ppmV) | ±2 °Cdp | polymer | 12 months (sensor exchange) | 2–3 years |
| SO₂ | 0–100 or 0–500 ppm | ±2 % FS | electrochemical | 12 months | 2–3 years |
| HF | 0–10 or 0–30 ppm | ±2 % FS | electrochemical | 12 months | 2–3 years |
| CF4 | 0–80 % | ±1 % of reading | calculated | not required | — |
| H₂S | 0–100 ppm | ±2 % FS | electrochemical | 12 months | 2–3 years |
| CO | 0–1000 ppm | ±2 % FS | electrochemical | 12 months | 2–3 years |
| Air / N₂ | 0–100 % | FS based on oxygen | electrochemical | 12 months | 2–3 years |
Technical specifications
| Parameter | Value |
|---|---|
| Warm-up | 3–4 min at 20 °C |
| Inlet pressure | up to 10 bar |
| Sample flow | 100–1000 mL/min |
| Pump (optional) | 0–1 L/min |
| Display | 7" (180 mm) colour LCD touch screen |
| Printer | integrated thermal printer |
| Memory | 4 GB, about one year of continuous logging |
| Data export | Excel-compatible files to a USB stick |
| Power | lithium battery over 8 h, 4–6 h charge, mains 90–260 V |
| Operating conditions | -10 to +40 °C, 10–90 % RH |
| Housing | heavy-duty IP66 case |
| Dimensions | 180 × 480 × 360 mm (H × W × D) |
| Weight | 8.5 kg with case |
Which Rapidox SF6 model to choose
| Model | Sample handling | Weight | Best for |
|---|---|---|---|
| Rapidox SF6 6100 Portable | into a recovery bag | 8.5 kg | Mobile crews, occasional testing |
| Rapidox SF6 6100 Pump Back | returned to equipment | 20 kg | Regular testing with no gas loss |
| Rapidox SF6 6100 Bench | into a bag or recovery system | 6.5 kg | Laboratories, manufacturing |
Supply in Kazakhstan
KEG TRK supplies Cambridge Sensotec analysers to power utilities and substation services. We help select the sensor set and couplings for your apparatus. Price on request.
Technical specifications
| Gas purity | SF6 0–100 %, ±0.5 % (IR) |
| Moisture (dew point) | -60 to +20 °Cdp (10–24,000 ppmV), ±2 °Cdp |
| Decomposition products | SO₂ 0–100/500 ppm, HF 0–10/30 ppm, H₂S 0–100 ppm, CO 0–1000 ppm, CF4 0–80 % |
| Pressure | up to 10 bar inlet |
| Pump | optional pump 0–1 L/min |
| Display | 7" (180 mm) colour LCD touch screen |
| Printer | integrated thermal printer |
| Memory | 4 GB, about one year of continuous logging |
| Battery | lithium, over 8 hours, 4–6 h charge |
| Operating conditions | -10 to +40 °C, 10–90 % RH |
| Protection | IP66 case |
| Weight | 8.5 kg (instrument with case) |
| Dimensions | 180 × 480 × 360 mm (H × W × D) |
Applications
Manufacturer
Cambridge Sensotec
Lightweight (8.5 kg) SF6 analyser for medium and high voltage GIS and breakers: purity, moisture and decomposition products, up to 8 gases at once. The sample is collected in a bag, not vented.
Key specifications
- Gas purity
- SF6 0–100 %, ±0.5 % (IR)
- Moisture (dew point)
- -60 to +20 °Cdp (10–24,000 ppmV), ±2 °Cdp
- Decomposition products
- SO₂ 0–100/500 ppm, HF 0–10/30 ppm, H₂S 0–100 ppm, CO 0–1000 ppm, CF4 0–80 %
- Pressure
- up to 10 bar inlet
- Pump
- optional pump 0–1 L/min
Official supplier in Kazakhstan
Related products

Rapidox SF6 6100 MK2 Pump Back — SF6 Analyser with Gas Return
Fully automatic zero-emissions SF6 analyser: purity, moisture and decomposition products in 2–8 minutes, then a compressor returns the gas to the equipment at up to 10 bar. Three calibrations for cold, warm and hot climates.
- SF6 0–100 %, ±0.5 % (IR or density)
- -60 to +20 °Cdp (10–24,000 ppmV), ±2 °Cdp

Rapidox SF6 6100 Bench — Benchtop and Rack-Mount SF6 Analyser
Fixed SF6 analyser for laboratories, factories and test bays: benchtop or 19" rack. Purity, moisture and decomposition products, 4–20 mA and 0–10 V outputs, alarm relays, RS232/RS485 and Modbus.
- SF6 0–100 %, ±0.5 % FS
- -60 to +20 °Cdp, ±2 °Cdp

Rapidox 6100 QU4D Multi-Gas Pumpback — SF6, C4-FN, C5-FK and Clean Air Analyser
One portable pump-back analyser for four insulation types: SF6, C4-FN, C5-FK and Clean Air. Purity, moisture and decomposition products in 2–8 minutes, with IEC and CIGRE test configurations built in.
- SF6 + CF4; C4-FN + CO₂/O₂; C5-FK + CO₂; Clean Air (N₂ + O₂)
- SF6 0–100 %, ±0.5 % (IR or density)

Rapidox SF6 Gas Recovery Bag — Bag for Collecting SF6 After Analysis
80-litre bag for collecting SF6 after analysis: self-sealing couplings, 0.2 bar safety relief valve, heavy-duty PU-coated polyamide. Compatible with the Rapidox SF6 6100 Portable and Bench.
- up to 80 L
- max 0.24 bar; relief valve 0.2 bar; vacuum to -50 mbar

SF6 Hose Connection Kit - Insulating Gas Hose Connection Set
Universal RECTUS 21 adapter kit for connecting SF6 gas analyzers to Siemens, ABB, Hitachi, Schneider, GE and Mitsubishi equipment, in an impact-resistant IP65 case
- SF6 auxiliary equipment
- RECTUS 21 (Series 21) — industry standard
Need advice?
Our specialists will help you choose the optimal Rapidox SF6 6100 Portable — Portable SF6 Gas Analyser configuration for your equipment.
Related articles
All articles →
How to Test SF6 Gas Quality at a Substation: Step-by-Step Guide
SF6 gas quality is tested with an analyser connected directly to the compartment: SF6 purity, moisture and decomposition products. What to measure, how to connect, what to compare the result with and when to test the gas.

SF6 Moisture Limits: Dew Point, ppmv and How to Measure Water in SF6
SF6 moisture is stated in ppmv or as a dew point. The acceptable water content depends on the gas pressure in the equipment. How to convert the units and measure moisture with a Rapidox SF6 6100.
SF6 Decomposition Products: SO2, HF and What to Do About Them
Discharges and arcs break SF6 down into SO2, HF, SOF2, S2F10 and metal fluoride dust. Why they are dangerous, which exposure limits apply and how to measure them with an analyser.

Predictive Maintenance Cuts Equipment Failures by 73%. That Is Not Marketing — It Is Data
Fixed maintenance calendars do not stop unplanned downtime: up to 15% of MRO effort is spent on unnecessary work. Sensor-driven predictive maintenance cuts downtime by 30–50% and equipment-related incidents by 40% — on mining, oil & gas and power sites in Kazakhstan and the CIS with Artesis, SDT and Rapidox.

Transformer DGA at CHP: What to Add Beyond Oil Chromatography
Dissolved gas analysis (DGA) is the gold standard for transformer diagnosis but not the only tool. Companion methods at CHP plants: cooling vibration, PD ultrasound, SF₆ and O₂ on adjacent switchgear.
Clean Air and Oxygen in SF₆-Free Switchgear: Monitoring at CHP During the SF₆ Transition
New dry-air (Clean Air) switchgear at CHP plants needs O₂, humidity and purity control. Rapidox 6100 Clean Air Pumpback for mixed SF₆ and SF₆-free fleets.