Поставка в Казахстане
KEG TRK поставляет решения для анализа элегаза SF6 (Cambridge Sensotec) по всему Казахстану: Алматы, Астана, Караганда, Усть-Каменогорск, Актобе и другие регионы. Официальная гарантия, проектирование систем мониторинга, монтаж, пусконаладка и обучение персонала.
Key features
Applications and resources
Industry solutions, landing pages and articles about Rapidox SF6 Gas Recovery Bag - SF6 Temporary Storage Bag
Where it is used
Typical tasks
- Temporary SF6 storage during analysis
- Equipment without gas return function
- Prevention of SF6 emissions
- Environmentally safe analysis
Heavy-duty recovery bag for collecting SF6 during analyzer servicing and equipment maintenance.
Description

Rapidox SF6 Gas Recovery Bag is a specialized bag for the temporary storage of sulfur hexafluoride (SF6) insulating gas during gas analysis. The solution was developed by Cambridge Sensotec (United Kingdom) to minimize SF6 emissions into the atmosphere and ensure environmental safety when working with electrical equipment.
Purpose and Applications
Why is an SF6 storage bag needed?
When analyzing the quality of insulating gas in electrical equipment, situations often arise where the gas cannot be returned to the system. This may be due to:
- The equipment lacking a gas return function
- The need to discharge the sample after analysis
- Laboratory research being carried out
The temporary SF6 storage bag solves this problem, allowing the gas to be safely collected and stored for subsequent disposal or reuse.
Application in the power industry
The bag is used in the following situations:
- Analysis of older equipment — where gas return is not possible
- Laboratory research — collecting samples for detailed analysis
- Emergency situations — collecting gas in the event of depressurization
- Scheduled maintenance — temporary collection during repairs
Environmental Benefits
Compliance with the Kyoto Protocol
Sulfur hexafluoride (SF6) is a potent greenhouse gas:
- Global Warming Potential (GWP) — 23,500 × CO2
- Atmospheric lifetime — 3,200 years
- Kyoto Protocol — requires minimizing emissions
Using the SF6 storage bag allows you to:
- Completely eliminate emissions during analysis
- Comply with environmental regulations
- Reduce the company's carbon footprint
- Demonstrate environmental responsibility
Technical Specifications
Bag parameters
| Parameter | Value |
|---|---|
| Capacity | 50 liters |
| Material | Durable, chemical-resistant material |
| Maximum pressure | 1.5 bar |
| Operating temperature | -20°C to +50°C |
| Weight | 1.5 kg |
| Dimensions | 600 × 400 × 200 mm |
| Compatibility | Rapidox SF6 6100 series |
Construction
- Durable material — resistant to tearing and chemical exposure
- Sealed joints — prevent leaks
- Convenient fittings — quick connection to the analyzer
- Carrying handles — for easy transport
Benefits of Use
Compared to atmospheric release
| Parameter | Atmospheric release | Storage bag |
|---|---|---|
| SF6 emissions | 100% | 0% |
| Environmental risk | High | None |
| Kyoto Protocol compliance | No | Yes |
| Reusability | No | Yes |
Economic benefits
- Reuse — SF6 can be returned to the system
- Purchase savings — new SF6 is expensive (~$100/kg)
- No fines — for environmental violations
- Improved reputation — as an environmentally responsible company
Method of Use
Connecting to the gas analyzer
- Connect the bag to the outlet port of the Rapidox gas analyzer
- Perform the analysis — the gas will be collected in the bag
- Disconnect the bag — after the analysis is complete
- Transport to the disposal or return location
Safety
- Do not exceed the pressure — maximum 1.5 bar
- Check for leaks — before use
- Store in a cool place — avoid direct sunlight
- Regular inspection — for damage
Scope of Delivery
Standard scope of delivery
- SF6 storage bag (50 liters)
- Connecting fittings
- User manual
Optional accessories
- Additional fittings — for different types of equipment
- Protective cover — for transport
- Calibration gases — for verification
Areas of Application
Types of equipment
- High-voltage circuit breakers — older models
- Medium-voltage circuit breakers — without gas return
- Switchgear — legacy models
- Transformers — during repairs
Industries
- Power industry — grid companies
- Industry — in-house substations
- Railways — traction substations
- Oil and gas — emergency power supply
Certification and Standards
Environmental standards
- Kyoto Protocol — reducing greenhouse gas emissions
- EU F-Gas Regulation — regulation of fluorinated gases
- ISO 14001 — environmental management system
Quality
- Cambridge Sensotec — British manufacturer
- ISO 9001 — quality management system
- Warranty — from the manufacturer
Why Rapidox SF6 Gas Recovery Bag?
For environmental responsibility
- Zero emission during analysis
- Compliance with the Kyoto Protocol
- Minimizing carbon footprint
- Environmental certification
For budget savings
- Reuse of SF6
- Reduced purchases of new gas
- No fines
- Fast payback
For ease of use
- Simple connection
- Easy to carry
- Durable construction
- Compatible with Rapidox
Technical Support
Training
- Instructions for use
- Safety requirements
- Environmental regulations
Service
- Warranty service
- Replacement in case of damage
- Technical consultation
Documents and Downloads
Technical specifications
| capacity | 50 liters |
| material | Durable, chemical-resistant material |
| compatibility | Rapidox SF6 6100 series |
| pressure | Maximum working pressure 1.5 bar |
| temperature | -20°C to +50°C |
| weight | 1.5 kg |
| dimensions | 600 × 400 × 200 mm |
| certification | Compliant with the Kyoto Protocol |
Applications
Manufacturer
Cambridge Sensotec
Bag for temporary storage of SF6 insulating gas during analysis to prevent emissions into the atmosphere
Key specifications
- capacity
- 50 liters
- material
- Durable, chemical-resistant material
- compatibility
- Rapidox SF6 6100 series
- pressure
- Maximum working pressure 1.5 bar
- temperature
- -20°C to +50°C
Official supplier in Kazakhstan
Related products
Rapidox SF6 6100 - Портативный газоанализатор элегаза
Портативный газоанализатор для измерения влажности, чистоты и продуктов разложения элегаза (SF6) в в...
Cambridge Sensotec
Rapidox SF6 6100 Pump Back - Газоанализатор с возвратом газа
Полностью автоматический газоанализатор элегаза с функцией возврата газа в оборудование для минимиза...
Cambridge Sensotec
Нужна консультация?
Наши специалисты помогут подобрать оптимальную конфигурацию Rapidox SF6 Gas Recovery Bag - SF6 Temporary Storage Bag для вашего оборудования.
Related articles
All articles →Oxygen Depletion in Enclosed MV Switchgear: O₂ and SF₆ Monitoring at CHP Substations
SF₆ leaks in enclosed switchgear displace oxygen below safe levels with no smell or visible warning. How to combine SF₆ and O₂ monitoring with Rapidox at combined heat and power substations.
Clean Air and Oxygen in SF₆-Free Switchgear: Monitoring at CHP During the SF₆ Transition
New dry-air (Clean Air) switchgear at CHP plants needs O₂, humidity and purity control. Rapidox 6100 Clean Air Pumpback for mixed SF₆ and SF₆-free fleets.
Vibration Monitoring of Power Transformer Cooling Auxiliaries at CHP Plants
Oil pumps, radiator fans and water-cooling pumps on step-up transformers are a hidden CHP outage source. Bently Nevada 3500/42M, Orbit DCM and 1900/65A for transformer yard auxiliaries.
Transformer DGA at CHP: What to Add Beyond Oil Chromatography
Dissolved gas analysis (DGA) is the gold standard for transformer diagnosis but not the only tool. Companion methods at CHP plants: cooling vibration, PD ultrasound, SF₆ and O₂ on adjacent switchgear.
Integrated Monitoring of CHP Transformer Bays: Rapidox, Vibration and Ultrasound
A CHP transformer bay is transformer, breakers, cooling and switchgear in one reliability loop. How to unify Rapidox (SF₆, O₂, Clean Air), Bently on oil pumps and SDT for partial discharges in one procedure.