Key features
Applications and resources
Industry solutions, landing pages and articles about SF6 Hose Connection Kit - Insulating Gas Hose Connection Set
Where it is used
Typical tasks
- High-voltage SF6 gas circuit breakers
- Gas-insulated switchgear (GIS)
- Gas-insulated lines (GIL)
- SF6-insulated transformers
- Substations with SF6 equipment
- Gas sampling directly from SF6 cylinders
Complete connection kit for linking Rapidox analyzers to GIS, breakers and gas compartments.
Description
The SF6 Hose Connection Kit from Cambridge Sensotec is a professional set of adapters for connecting gas analyzers to SF6-insulated equipment from various global manufacturers. The kit is housed in an impact-resistant, waterproof Pelican case (IP65) with foam inserts for reliable storage and transport to site.
All components are made from high-quality materials by original OEM manufacturers, including DILO — a world leader in SF6 technology. The kit includes a two-stage stainless steel pressure regulator, allowing gas samples to be taken directly from SF6 cylinders.
Which Equipment It Fits
Compatible SF6 equipment manufacturers
The kit contains adapters for gas compartments and switchgear from the following manufacturers:
- Siemens — high-voltage circuit breakers and GIS
- ABB — SF6 switching equipment
- Hitachi — SF6 circuit breakers
- Schneider Electric — gas-insulated cells
- GE (General Electric) — high-voltage equipment
- Mitsubishi — circuit breakers and switchgear
Types of connections included
The full kit configuration includes:
| No. | Connection | Purpose |
|---|---|---|
| 1 | RECTUS 21 (male) → ¼″ JIC (female) | American standard, small |
| 2 | RECTUS 21 (male) → 3/8″ JIC (female) | American standard, medium |
| 3 | RECTUS 21 (male) → ½″ JIC (female) | American standard, large |
| 4 | RECTUS 21 (male) → 1/4″ NPT (male) | NPT pipe thread — 4 pcs. |
| 5 | RECTUS 21 (male) → DN20 (female) | European DN20 |
| 6 | RECTUS 21 (male) → DN8 (female) | European DN8 |
| 7 | RECTUS 21 (male) → DN6 (female) | European DN6 |
| 8 | RECTUS 21 (male) → DN7 (female) | European DN7 |
| 9 | RECTUS 21 (male) → DN12 (female) | European DN12 |
| 10 | SF6 regulator + RECTUS 21 | For BS 431 No. 3/No. 6 cylinders |
RECTUS Series 21 Couplings
RECTUS Series 21 couplings are the worldwide industry standard for connecting sampling hoses to SF6 gas analyzers, including the entire Rapidox SF6 instrument range.
Key properties of RECTUS 21
- Self-sealing couplings — minimize SF6 leakage when connecting and disconnecting
- Secure locking — the connection cannot come apart accidentally
- Durability — rated for thousands of connection cycles
- Gas-tightness — meets the requirements for working with SF6
Technical Specifications
Kit parameters
| Parameter | Value |
|---|---|
| Type | SF6 auxiliary equipment |
| Coupling standard | RECTUS 21 (Series 21) |
| Case protection rating | IP65 |
| Case dimensions | 480 × 361 × 181 mm |
| Weight with accessories | 7 kg |
| Regulator material | Stainless steel |
| Cylinder fitting | BS 431 No. 3 (Air Products) / No. 6 (BOC) |
| Component manufacturer | DILO and other OEMs |
Benefits of the Kit
Configurable to customer needs
The kit is fully adaptable to the needs of a specific enterprise:
- Purchase only the adapters you need for your equipment fleet
- Ability to reorder individual components at any time
- Expand the kit as new equipment from other manufacturers appears
OEM component quality
| Criterion | SF6 Hose Connection Kit |
|---|---|
| Component manufacturer | DILO and OEM partners |
| Manufacturing quality | Industrial grade |
| Leakage during switching | Minimal (self-sealing couplings) |
| Compatibility | All major SF6 manufacturers |
Reliable transport
The impact-resistant Pelican IP65 case provides:
- Protection from dust and water (IP65 rating)
- Shock absorption for impacts and drops
- Organized storage — each component in its place
- Convenient carrying to site
Practical Application
Substation usage scenarios
Scheduled maintenance of SF6 breakers:
- Arrive on site with the kit case and a Rapidox gas analyzer
- Select the appropriate adapter for the equipment type (Siemens DN8, ABB DN20, etc.)
- Connect the analyzer's sampling hose to the gas compartment
- Perform the SF6 quality analysis (moisture, purity, decomposition products)
Sampling from an SF6 cylinder:
- Connect the kit's regulator to the SF6 cylinder
- Connect the gas analyzer via the RECTUS 21 fitting
- Check the quality of the fresh gas before filling the equipment
Compatibility with Rapidox gas analyzers
The kit is fully compatible with the entire Rapidox range:
- Rapidox SF6 6100 — portable analyzer
- Rapidox SF6 6100 Pumpback — with gas return function
- Rapidox SF6 6100 Bench — bench-top analyzer
Order Scope of Delivery
Standard scope of delivery
- Impact-resistant Pelican case with foam inserts, IP65
- 9 RECTUS 21 adapters for various standards
- Two-stage stainless steel SF6 regulator
- Cylinder fitting adapter for BS 431 No. 3 or No. 6 (on request)
- User manual
Custom configuration
On request, the kit can be supplied with only the adapters required for a specific equipment fleet. This reduces cost for specialized applications.
Standards and Compliance
- IEC 62271 — High-voltage equipment requirements
- IEC 60480 — Quality control of used SF6
- CIGRE — SF6 handling recommendations
- IP65 — Enclosure protection against dust and water
Documents
Technical specifications
| type | SF6 auxiliary equipment |
| couplings | RECTUS 21 (Series 21) — industry standard |
| regulator | Two-stage SF6 regulator, stainless steel |
| bottleFitting | BS 431 No. 3 (Air Products) or No. 6 (BOC) |
| caseDimensions | 480 × 361 × 181 mm (W × D × H) |
| weight | 7 kg |
| caseProtection | IP65 |
| material | Stainless steel, high-quality alloys |
| compatibility | Siemens, ABB, Hitachi, Schneider, GE, Mitsubishi |
Applications
Manufacturer
Cambridge Sensotec
Universal RECTUS 21 adapter kit for connecting SF6 gas analyzers to Siemens, ABB, Hitachi, Schneider, GE and Mitsubishi equipment, in an impact-resistant IP65 case
Key specifications
- type
- SF6 auxiliary equipment
- couplings
- RECTUS 21 (Series 21) — industry standard
- regulator
- Two-stage SF6 regulator, stainless steel
- bottleFitting
- BS 431 No. 3 (Air Products) or No. 6 (BOC)
- caseDimensions
- 480 × 361 × 181 mm (W × D × H)
Official supplier in Kazakhstan
Related products
Rapidox SF6 6100 - Портативный газоанализатор элегаза
Портативный газоанализатор для измерения влажности, чистоты и продуктов разложения элегаза (SF6) в в...
Cambridge Sensotec
Rapidox SF6 6100 Pump Back - Газоанализатор с возвратом газа
Полностью автоматический газоанализатор элегаза с функцией возврата газа в оборудование для минимиза...
Cambridge Sensotec
Rapidox SF6 Gas Recovery Bag - Мешок для временного хранения SF6
Мешок для временного хранения элегаза SF6 при анализе для предотвращения выбросов в атмосферу
Cambridge Sensotec
SF6 Leakmate - Портативный течеискатель элегаза SF6
Портативный течеискатель SF6 с порогом обнаружения 1×10⁻⁶ мбар·л/с для мобильного поиска утечек элег...
Cambridge Sensotec
Нужна консультация?
Наши специалисты помогут подобрать оптимальную конфигурацию SF6 Hose Connection Kit - Insulating Gas Hose Connection Set для вашего оборудования.
Related articles
All articles →Clean Air and Oxygen in SF₆-Free Switchgear: Monitoring at CHP During the SF₆ Transition
New dry-air (Clean Air) switchgear at CHP plants needs O₂, humidity and purity control. Rapidox 6100 Clean Air Pumpback for mixed SF₆ and SF₆-free fleets.
Oxygen Depletion in Enclosed MV Switchgear: O₂ and SF₆ Monitoring at CHP Substations
SF₆ leaks in enclosed switchgear displace oxygen below safe levels with no smell or visible warning. How to combine SF₆ and O₂ monitoring with Rapidox at combined heat and power substations.
Vibration Monitoring of Power Transformer Cooling Auxiliaries at CHP Plants
Oil pumps, radiator fans and water-cooling pumps on step-up transformers are a hidden CHP outage source. Bently Nevada 3500/42M, Orbit DCM and 1900/65A for transformer yard auxiliaries.
Transformer DGA at CHP: What to Add Beyond Oil Chromatography
Dissolved gas analysis (DGA) is the gold standard for transformer diagnosis but not the only tool. Companion methods at CHP plants: cooling vibration, PD ultrasound, SF₆ and O₂ on adjacent switchgear.
Integrated Monitoring of CHP Transformer Bays: Rapidox, Vibration and Ultrasound
A CHP transformer bay is transformer, breakers, cooling and switchgear in one reliability loop. How to unify Rapidox (SF₆, O₂, Clean Air), Bently on oil pumps and SDT for partial discharges in one procedure.
How to Test SF6 Gas Quality at a Substation: Step-by-Step Guide
Moisture, decomposition products and pressure loss in HV breakers and GIS — what to measure, IEC limits and how Rapidox analyzers sample SF6 without venting the compartment.