Cambridge SensotecSF6 Analyzers

Rapidox SF6 6100 Pump Back - Gas Analyzer with Gas Return

Fully automatic SF6 gas analyzer with gas return function to minimize emissions

Rapidox SF6 6100 Pump Back - Gas Analyzer with Gas Return — Cambridge Sensotec
Rapidox SF6 6100 Pump Back - Gas Analyzer with Gas Return

Поставка в Казахстане

KEG TRK поставляет решения для анализа элегаза SF6 (Cambridge Sensotec) по всему Казахстану: Алматы, Астана, Караганда, Усть-Каменогорск, Актобе и другие регионы. Официальная гарантия, проектирование систем мониторинга, монтаж, пусконаладка и обучение персонала.

Key features

Fully automatic analysis
SF6 return function to equipment
Zero gas emissions (Zero Emission)
Built-in vacuum pump
7-inch touchscreen display
Up to 8 hours of autonomous operation
IP66 protection in a rugged Peli case

Industry solutions, landing pages and articles about Rapidox SF6 6100 Pump Back - Gas Analyzer with Gas Return

Typical tasks

  • High-voltage circuit breakers with gas return
  • Gas-insulated lines (GIL)
  • SF6-insulated transformers
  • SF6 savings during diagnostics
  • Environmentally safe analysis

Field SF6 quality analyzer with pump-back function — minimizes gas loss during HV equipment testing.

Description

The Rapidox SF6 6100 Pump Back is a premium, fully automatic SF6 gas analyzer from Cambridge Sensotec (United Kingdom) featuring a unique function that returns gas back into the equipment after analysis. It is a Zero Emission solution that minimizes losses of expensive SF6 gas and protects the environment.

Key Difference: Pump Back Function

What is Pump Back?

Pump Back is a built-in SF6 gas return system:

  • Sampling — gas is drawn from the equipment
  • Analysis — measurement of all quality parameters
  • Return — clean SF6 is pumped back
  • Result — minimal gas loss

Why is gas return needed?

Economic benefits

  • SF6 is an expensive gas — priced up to $100+ per kg
  • Loss minimization — return of up to 99% of gas
  • Refill savings — fewer purchases of new gas
  • Fast payback — within a few analyses

Environmental benefits

  • SF6 is a greenhouse gas — 23,500 times more potent than CO2
  • Zero Emission — zero emissions into the atmosphere
  • Kyoto Protocol compliance — reduction of emissions
  • Environmental responsibility — green technologies

Operational benefits

  • No pressure drop — gas is returned to the system
  • No equipment downtime — no refilling required
  • Fast analysis — automatic cycle
  • Safety — minimal gas handling

Technical Specifications

Measurement parameters

Parameter Range Accuracy
SF6 (purity) 0 — 100% ±0.5%
Moisture (Td) -60°C to +20°C ±2°C
SO2 0 — 1000 ppm ±5%
H2S 0 — 1000 ppm ±5%
Other gases Up to 8 simultaneously Per specification

Pump system

Characteristic Value
Pump type Built-in vacuum
Capacity Automatic
Gas return Up to 99%
Return pressure As in the equipment

Physical parameters

Parameter Value
Display 7" touchscreen TFT (180 mm)
Protection IP66 (Peli case)
Weight 21 kg with case
Dimensions 500 × 400 × 250 mm
Battery Li-Ion, up to 8 hours
Case Peli with wheels and handle

Full Automation

Walk Away Timer

  • Start delay — "walk away and return" timer
  • Automatic start — analysis begins on a timer
  • Free time — attend to other tasks
  • Auto-completion — full cycle without intervention

Auto-Abort Function

  • Error control — automatic problem detection
  • Safe shutdown — in the event of deviations
  • Equipment protection — prevents damage
  • Diagnostics — error reporting

Auto-Clean Function

  • Sensor cleaning — after each measurement
  • Extended service life — sensors last longer
  • Accuracy — stable results
  • Automatic — no operator involvement

Operating Modes

Standard Pump Back mode

  1. Connection to the test valve
  2. Sampling — automatic gas draw
  3. Analysis — measurement of all parameters
  4. Return — pumping SF6 back
  5. Report — saving results

Gas Cylinder Mode

  • Analysis of SF6 from cylinders
  • Quality verification of new gas
  • Control of gas for refilling
  • Acceptance testing

Direct Mode

  • Measurement without return
  • For systems without gas return
  • Rapid analysis

Built-in Tests and Standards

CIGRE Tests

International tests for SF6 equipment:

  • CIGRE B3.02 — SF6 quality analysis
  • CIGRE TF — working group recommendations
  • Automatic protocols — format compliance

IEC Standards

  • IEC 60480 — used SF6 gas
  • IEC 62271-100 — high-voltage switchgear
  • IEC 62067 — SF6 cable lines
  • Automatic evaluation — pass/fail against standards

Unique Technologies

Rapidri System

  • Accelerated operation — faster than standard cycles
  • Special procedure — optimized analysis
  • Time savings — up to 40% faster
  • Accuracy preserved — no compromises

Modular Sensor Choice

  • Up to 8 gases — simultaneously
  • Modular sensors — easy replacement
  • Configuration — tailored to customer tasks
  • Future upgrades — new sensors

Applications of the Rapidox SF6 6100 Pump Back

Usage scenarios

Commissioning

  • SF6 quality verification after installation
  • Analysis before first power-up
  • Documentation for warranty
  • Gas return — with no losses

Scheduled maintenance

  • Regular condition monitoring
  • Diagnosis of equipment aging
  • Control of decomposition products
  • Minimizing refills

After an emergency shutdown

  • Analysis of the causes of the failure
  • Verification of gas condition
  • Decision on replacement/restoration
  • Savings on new gas

Environmental control

  • SF6 emissions accounting
  • Reporting for the Kyoto Protocol
  • ISO 14001 certification
  • Green energy

Advantages over Standard Analysis

Comparison of analysis methods

Method Gas loss Time Cost
Laboratory analysis 100% Days High
Standard portable 100% Minutes Medium
Pump Back <1% Minutes Fast payback

Economic impact

  • SF6 cost — ~$100 per kg
  • Loss during analysis — typically 2-5 kg
  • Pump Back savings — $200-500 per analysis
  • Payback — after 10-20 analyses

Applications

Equipment types

  • High-voltage circuit breakers — 110kV, 220kV, 500kV
  • Medium-voltage circuit breakers — 6kV, 10kV, 35kV
  • Gas-insulated lines (GIL) — long-distance lines
  • Transformers — with SF6 insulation
  • Switchgear (GIS) — packaged substations

Industries

  • Power industry — grid companies
  • Industry — in-house substations
  • Railways — traction substations
  • Oil and gas — emergency power supply
  • Metallurgy — major power consumers

Scope of Delivery

Standard scope of delivery

  • Rapidox SF6 6100 Pump Back gas analyzer
  • Built-in vacuum pump
  • Rugged Peli case with wheels
  • Lithium battery
  • Charger (220V + car charger)
  • 2-meter sampling hose
  • Connection fittings
  • User manual

Optional accessories

  • Built-in printer — on-site printing
  • Additional sensors — extended analysis
  • Calibration gases — for verification
  • Special fittings — for different equipment types
  • PC software — data analysis

Multilingual Support

Supported languages

  • Russian
  • English
  • Deutsch
  • Français
  • Español
  • Others upon request

Localization

  • Interface in the selected language
  • Reports in the user's language
  • Compliance with local standards

Calibration and Service

Calibration

  • Interval — every 12 months
  • Sensor service life — more than 5 years
  • Modular replacement — by the user
  • Accredited centers — worldwide

Technical support

  • Warranty — from the manufacturer
  • Training — operator certification
  • Hotline — technical support
  • Updates — via USB

Environmental Responsibility

Zero Emission Technology

The Rapidox SF6 6100 Pump Back is a zero-emission solution:

  • Minimize SF6 emissions — reducing emissions
  • Environmental protection — safeguarding the environment
  • Regulatory compliance — meeting requirements
  • Sustainable future — sustainable development

SF6 and Climate

  • Global warming potential — 23,500 × CO2
  • Atmospheric lifetime — 3,200 years
  • Kyoto Protocol — emissions regulation
  • EU F-Gas Regulation — restrictions in Europe

Why Choose the Rapidox SF6 6100 Pump Back?

For environmentally responsible companies

  • Zero emission technology
  • Kyoto Protocol compliance
  • Emissions reporting
  • Green certification

For budget savings

  • Minimizing SF6 purchases
  • Fast payback
  • Reduced operating costs
  • Automation — less labor

For measurement quality

  • Cambridge Sensotec quality
  • Full automation
  • Built-in CIGRE/IEC tests
  • Modular sensors

Documents and Standards

Technical documentation

Standards

  • IEC 60480 — Guide for used SF6
  • IEC 62271 — High-voltage equipment
  • CIGRE — SF6 recommendations
  • CE — European conformity

Comparison with the Rapidox SF6 6100 Standard

Characteristic SF6 6100 Standard SF6 6100 Pump Back
Gas return No Yes
Weight 8.5 kg 21 kg
Automation Full Full + pump
SF6 emissions 100% of sample <1%
Cost Base Premium
Application General analysis Gas savings

Model Selection

Choose Standard if:

  • You have a limited budget
  • You need lightweight portability
  • You are analyzing new installations
  • You have no gas-return requirements

Choose Pump Back if:

  • You perform frequent equipment analysis
  • SF6 gas is expensive for you
  • You have environmental requirements
  • Gas savings are important to you

Manufacturer

Cambridge Sensotec

SF6 Analyzers

Fully automatic SF6 gas analyzer with gas return function to minimize emissions

Key specifications

display
7-inch touchscreen TFT display (180 mm)
humidity
-60°C to +20°C dew point
purity
0 - 100% SF6 with ±0.5% accuracy
decomposition
SO2, H2S and other gases up to 1000 ppm
pump
Built-in vacuum pump
CallRequest a quote

Official supplier in Kazakhstan

Нужна консультация?

Наши специалисты помогут подобрать оптимальную конфигурацию Rapidox SF6 6100 Pump Back - Gas Analyzer with Gas Return для вашего оборудования.

Related articles

All articles
Article

Transformer DGA at CHP: What to Add Beyond Oil Chromatography

Dissolved gas analysis (DGA) is the gold standard for transformer diagnosis but not the only tool. Companion methods at CHP plants: cooling vibration, PD ultrasound, SF₆ and O₂ on adjacent switchgear.

Application

Integrated Monitoring of CHP Transformer Bays: Rapidox, Vibration and Ultrasound

A CHP transformer bay is transformer, breakers, cooling and switchgear in one reliability loop. How to unify Rapidox (SF₆, O₂, Clean Air), Bently on oil pumps and SDT for partial discharges in one procedure.

Article

Clean Air and Oxygen in SF₆-Free Switchgear: Monitoring at CHP During the SF₆ Transition

New dry-air (Clean Air) switchgear at CHP plants needs O₂, humidity and purity control. Rapidox 6100 Clean Air Pumpback for mixed SF₆ and SF₆-free fleets.

Article

Oxygen Depletion in Enclosed MV Switchgear: O₂ and SF₆ Monitoring at CHP Substations

SF₆ leaks in enclosed switchgear displace oxygen below safe levels with no smell or visible warning. How to combine SF₆ and O₂ monitoring with Rapidox at combined heat and power substations.

Application

Vibration Monitoring of Power Transformer Cooling Auxiliaries at CHP Plants

Oil pumps, radiator fans and water-cooling pumps on step-up transformers are a hidden CHP outage source. Bently Nevada 3500/42M, Orbit DCM and 1900/65A for transformer yard auxiliaries.

Article

How to Test SF6 Gas Quality at a Substation: Step-by-Step Guide

Moisture, decomposition products and pressure loss in HV breakers and GIS — what to measure, IEC limits and how Rapidox analyzers sample SF6 without venting the compartment.