Supply in Kazakhstan
KEG TRK supplies SF6 gas analysis solutions (Cambridge Sensotec) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.
Key features
Applications and resources
Industry solutions, landing pages and articles about Rapidox SF6 6100 Bench — Benchtop and Rack-Mount SF6 Analyser
Where it is used
Typical tasks
- Utility and service centre laboratories
- Manufacture and repair of SF6 equipment
- SF6 purity checks during reclaim and cylinder filling
- Test benches with data output to control systems
- Research and development
Documentation
Official manufacturer PDF documents. Key specifications are also published on this page.
Need a price with delivery in Kazakhstan? We will prepare a quotation for your task.
Laboratory-grade Rapidox SF6 6100 Bench for precise moisture, purity and decomposition analysis.
Overview
The Rapidox SF6 6100 Bench is a fixed SF6 analyser from the British company Cambridge Sensotec. It is used where gas is analysed at a permanent workstation: utility laboratories, SF6 equipment factories, reclaim and cylinder-filling areas, and research.
Two versions are available: benchtop with a swing handle, and 19-inch rack mount for industrial cabinets. It runs on mains power; there is no battery.
What it measures
| Parameter | Range | Accuracy |
|---|---|---|
| SF6 | 0–100 % | ±0.5 % FS |
| H₂O (dew point) | -60 to +20 °Cdp | ±2 °Cdp of reading |
| SO₂ | 0–100 to 0–2000 ppm | ±2 % FS |
| HF | 0–10 or 0–20 ppm | ±2 % FS |
| CF4 | 0–80 % | ±1 % of reading (calculated) |
| H₂S | 0–200 to 0–2000 ppm | ±2 % FS |
| CO | 0–500 to 0–5000 ppm | ±2 % FS |
| Air (via O₂) | 0–100 % | ±5 % FS |
The sensor set is chosen for the task. Not every combination is possible because of cross-sensitivity, so the configuration is agreed with the manufacturer.
Sampling
- Pressurised. Gas from a compartment or cylinder at up to 10 bar flows through on its own; the pump is off.
- Atmospheric or below. The optional pump (up to 1 L/min) is switched on.
- Flow is set with a rotary knob on the front panel and shown on screen.
- Modes: timed or continuous sampling.
- Spent gas leaves through an outlet nozzle to a recovery bag or a standard reclaim system.
Integration
- programmable 4–20 mA and 0–10 V analogue outputs;
- programmable alarm relay circuits;
- RS232 (RS485 option), on-demand data streaming, Modbus RTU / Ethernet;
- Excel export via USB stick;
- password protection, Rapidox data-logging software;
- optional thermal printer.
Technical specifications
| Parameter | Value |
|---|---|
| Warm-up | 3–4 min at 20 °C |
| Inlet pressure | up to 10 bar (protected) |
| Sample connection | Rectus-style closed-coupled fitting; option: DN8/DN20 couplings with stainless braided hose |
| Pump (optional) | 0–1 L/min, long-life, variable speed |
| Display | 7" (180 mm) colour LCD touch screen, 0.01 ppm or 0.01 % resolution |
| Power | mains 90–260 V, 50/60 Hz |
| Operating conditions | 0 to +40 °C, 10–90 % RH, 900–1100 mbar |
| Dimensions, rack | 132 × 482 × 365 mm (H × W × D) |
| Dimensions, benchtop | 180 × 570 × 345 mm (H × W × D) |
| Weight | 6.5 kg |
Other Rapidox SF6 analysers
- Rapidox SF6 6100 Portable — light battery-powered field instrument.
- Rapidox SF6 6100 Pump Back — field instrument that returns gas to the equipment.
- Rapidox SF6 Fixed Detection System — permanent SF6 leak monitoring in rooms.
Supply in Kazakhstan
KEG TRK supplies Cambridge Sensotec analysers to utility laboratories, service centres and manufacturers. We help choose the version, sensor set and interfaces for your system. Price on request.
Technical specifications
| Gas purity | SF6 0–100 %, ±0.5 % FS |
| Moisture (dew point) | -60 to +20 °Cdp, ±2 °Cdp |
| Decomposition products | SO₂ up to 2000 ppm, HF 0–10/20 ppm, H₂S up to 2000 ppm, CO up to 5000 ppm, CF4 0–80 % |
| O₂ / air | air 0–100 %, ±5 % FS based on oxygen |
| Outputs | 4–20 mA and 0–10 V, programmable |
| Relays | programmable alarm relay circuits |
| Communication | RS232 (RS485 option), Modbus RTU / Ethernet, USB |
| Pressure | up to 10 bar inlet (protected) |
| Pump | optional pump 0–1 L/min |
| Display | 7" (180 mm) colour LCD touch screen, 0.01 ppm or 0.01 % resolution |
| Power | mains 90–260 V, 50/60 Hz |
| Operating conditions | 0 to +40 °C, 10–90 % RH |
| Dimensions | rack: 132 × 482 × 365 mm; benchtop: 180 × 570 × 345 mm |
| Weight | 6.5 kg |
Applications
Manufacturer
Cambridge Sensotec
Fixed SF6 analyser for laboratories, factories and test bays: benchtop or 19" rack. Purity, moisture and decomposition products, 4–20 mA and 0–10 V outputs, alarm relays, RS232/RS485 and Modbus.
Key specifications
- Gas purity
- SF6 0–100 %, ±0.5 % FS
- Moisture (dew point)
- -60 to +20 °Cdp, ±2 °Cdp
- Decomposition products
- SO₂ up to 2000 ppm, HF 0–10/20 ppm, H₂S up to 2000 ppm, CO up to 5000 ppm, CF4 0–80 %
- O₂ / air
- air 0–100 %, ±5 % FS based on oxygen
- Outputs
- 4–20 mA and 0–10 V, programmable
Official supplier in Kazakhstan
Related products

Rapidox SF6 6100 Portable — Portable SF6 Gas Analyser
Lightweight (8.5 kg) SF6 analyser for medium and high voltage GIS and breakers: purity, moisture and decomposition products, up to 8 gases at once. The sample is collected in a bag, not vented.
- SF6 0–100 %, ±0.5 % (IR)
- -60 to +20 °Cdp (10–24,000 ppmV), ±2 °Cdp

Rapidox SF6 6100 MK2 Pump Back — SF6 Analyser with Gas Return
Fully automatic zero-emissions SF6 analyser: purity, moisture and decomposition products in 2–8 minutes, then a compressor returns the gas to the equipment at up to 10 bar. Three calibrations for cold, warm and hot climates.
- SF6 0–100 %, ±0.5 % (IR or density)
- -60 to +20 °Cdp (10–24,000 ppmV), ±2 °Cdp

Rapidox SF6 Fixed Detection System — Permanent SF6 Leak Monitoring for Rooms
Continuous SF6 leak monitoring for GIS rooms and substations: an Oldham MX32 or MX43 panel with 1 to 8 OLCT-XPIR infrared detectors (0–2,000 ppm SF6), strobe and horn alarms.
- MX32 panel (1–2 detectors) or MX43 (1–8 detectors)
- Oldham OLCT-XPIR SF6, infrared, 4–20 mA, ATEX

Rapidox SF6 Gas Recovery Bag — Bag for Collecting SF6 After Analysis
80-litre bag for collecting SF6 after analysis: self-sealing couplings, 0.2 bar safety relief valve, heavy-duty PU-coated polyamide. Compatible with the Rapidox SF6 6100 Portable and Bench.
- up to 80 L
- max 0.24 bar; relief valve 0.2 bar; vacuum to -50 mbar

SF6 Hose Connection Kit - Insulating Gas Hose Connection Set
Universal RECTUS 21 adapter kit for connecting SF6 gas analyzers to Siemens, ABB, Hitachi, Schneider, GE and Mitsubishi equipment, in an impact-resistant IP65 case
- SF6 auxiliary equipment
- RECTUS 21 (Series 21) — industry standard
Need advice?
Our specialists will help you choose the optimal Rapidox SF6 6100 Bench — Benchtop and Rack-Mount SF6 Analyser configuration for your equipment.
Related articles
All articles →
Oxygen Depletion in Enclosed MV Switchgear: O₂ and SF₆ Monitoring at CHP Substations
SF₆ leaks in enclosed switchgear displace oxygen below safe levels with no smell or visible warning. How to combine SF₆ and O₂ monitoring with Rapidox at combined heat and power substations.
Clean Air and Oxygen in SF₆-Free Switchgear: Monitoring at CHP During the SF₆ Transition
New dry-air (Clean Air) switchgear at CHP plants needs O₂, humidity and purity control. Rapidox 6100 Clean Air Pumpback for mixed SF₆ and SF₆-free fleets.

Vibration Monitoring of Power Transformer Cooling Auxiliaries at CHP Plants
Oil pumps, radiator fans and water-cooling pumps on step-up transformers are a hidden CHP outage source. Bently Nevada 3500/42M, Orbit DCM and 1900/65A for transformer yard auxiliaries.

Transformer DGA at CHP: What to Add Beyond Oil Chromatography
Dissolved gas analysis (DGA) is the gold standard for transformer diagnosis but not the only tool. Companion methods at CHP plants: cooling vibration, PD ultrasound, SF₆ and O₂ on adjacent switchgear.

Integrated Monitoring of CHP Transformer Bays: Rapidox, Vibration and Ultrasound
A CHP transformer bay is transformer, breakers, cooling and switchgear in one reliability loop. How to unify Rapidox (SF₆, O₂, Clean Air), Bently on oil pumps and SDT for partial discharges in one procedure.