Поставка в Казахстане
KEG TRK поставляет решения для анализа элегаза SF6 (Cambridge Sensotec) по всему Казахстану: Алматы, Астана, Караганда, Усть-Каменогорск, Актобе и другие регионы. Официальная гарантия, проектирование систем мониторинга, монтаж, пусконаладка и обучение персонала.
Key features
Applications and resources
Industry solutions, landing pages and articles about Rapidox SF6 Fixed Detection System - Fixed Monitoring System
Where it is used
Typical tasks
- Substation monitoring
- Switchgear control
- Leak detection in enclosed spaces
- Integration into safety systems
Permanent SF6 leak and atmosphere monitoring system for personnel safety and environmental compliance.
Description
Rapidox SF6 Fixed Detection System is a fixed continuous monitoring system for detecting sulfur hexafluoride (SF6) insulating gas leaks from Cambridge Sensotec (United Kingdom). The system is designed for installation at substations, switchgear and other power industry facilities where continuous SF6 quality control and leak detection are required.
Purpose and Applications
Rapidox SF6 Fixed Detection System is a fixed continuous monitoring system for detecting sulfur hexafluoride (SF6) insulating gas leaks from Cambridge Sensotec (United Kingdom). The system is designed for installation at substations, switchgear and other power industry facilities where continuous SF6 quality control and leak detection are required.
Purpose and Applications
Why is a fixed monitoring system needed?
Sulfur hexafluoride (SF6) is used in high-voltage equipment as an insulating and arc-quenching medium. SF6 leaks present a serious problem:
- Environmental risk — SF6 is a potent greenhouse gas (GWP 23,500)
- Equipment safety — a pressure drop reduces dielectric strength
- Economic losses — SF6 is an expensive gas (~$100/kg)
- Regulatory compliance — regular monitoring is required
A fixed monitoring system solves these problems by providing:
- Continuous control — 24 hours a day, 7 days a week
- Early detection — of leaks at an early stage
- Automatic alarm — immediate notification
- SCADA integration — centralized monitoring
Application in the power industry
The system is used at the following facilities:
- Substations — monitoring of bays and switchgear cells
- Gas-insulated switchgear (GIS) — sealing control
- Enclosed spaces — leak detection in the atmosphere
- Transformer substations — comprehensive monitoring
Key Features
Continuous 24/7 monitoring
- Automatic mode — no operator involvement required
- Continuous control — round-the-clock monitoring
- Data logging — history of changes
- Trend analysis — identifying problems
High sensitivity
- Detection threshold — from 1 ppm SF6
- Fast response — less than 10 seconds
- Accurate measurements — minimizing false alarms
- Multi-point connection — up to 16 sensors
SCADA integration
- Modbus TCP/IP — standard protocol
- Ethernet — network connection
- Analog outputs — 4-20 mA
- Relay outputs — for alarm signaling
Alarm signaling
- Visual — indicators on the panel
- Audible — siren or buzzer
- Relay — connection of external devices
- SMS/Email — remote notification
Technical Specifications
Measurement parameters
| Parameter | Value |
|---|---|
| Measurement range | 0 - 1000 ppm SF6 |
| Sensitivity | From 1 ppm |
| Response time | Less than 10 seconds |
| Accuracy | ±5% of reading |
| Number of sensors | Up to 16 points |
Connection and interface
| Parameter | Value |
|---|---|
| Protocols | Modbus TCP/IP, Ethernet |
| Analog outputs | 4-20 mA |
| Relay outputs | 4 (programmable) |
| USB | For configuration |
| Display | Graphic LCD |
Physical parameters
| Parameter | Value |
|---|---|
| Power supply | 220V AC / 24V DC |
| Consumption | Max. 50W |
| Operating temperature | -20°C to +50°C |
| Protection | IP65 |
| Dimensions | 482 × 177 × 340 mm (19" rack) |
| Mounting | Wall-mounted or rack |
Installation Procedure
Choosing the installation location
- Identify risk zones — possible leak points
- Install sensors — in cells and switchgear bays
- Connect to the controller — with cable up to 100 m
- Set thresholds — alarm and warning levels
- Integrate with SCADA — for centralized monitoring
Configuration
- Threshold values — setting alarm levels
- Trigger delay — to exclude false alarms
- Logging — data recording frequency
- Notifications — SMS/Email setup
Benefits
Compared to periodic inspection
| Parameter | Periodic inspection | Fixed system |
|---|---|---|
| Monitoring | Staff visits | Continuous 24/7 |
| Leak detection | At the next visit | In real time |
| Gas losses | Significant | Minimal |
| Personnel costs | High | Minimal |
Economic effect
- Reduced SF6 losses — early leak detection
- Minimized downtime — fast response
- Reduced personnel costs — automatic monitoring
- No fines — for environmental violations
Areas of Application
Types of facilities
- High-voltage substations — 110kV, 220kV, 500kV
- Medium-voltage substations — 6kV, 10kV, 35kV
- Gas-insulated switchgear (GIS) — packaged substations
- Enclosed spaces — with SF6 equipment
Industries
- Power industry — grid companies
- Industry — in-house substations
- Railways — traction substations
- Oil and gas — emergency power supply
Scope of Delivery
Standard scope of delivery
- Monitoring controller
- Basic sensor set (4 pcs.)
- Mounting kit
- Connection cables
- User manual
Optional accessories
- Additional sensors — up to 16 points
- Audible siren — for alarm signaling
- SMS module — for remote notifications
- PC software — for data analysis
Calibration and Maintenance
Calibration
- Frequency — every 12 months
- Sensor lifetime — more than 5 years
- Sensor replacement — modular, by the user
- Accredited centers — worldwide
Technical support
- Warranty — from the manufacturer
- Training — for personnel
- Hotline — technical support
- Updates — via USB
Certification and Standards
Compliance with standards
- IEC 62271 — High-voltage equipment
- IEC 60480 — Guide to SF6
- ISO 9001 — Quality management system
- CE — European conformity
Safety
- IP65 — protection against dust and water
- Electrical safety — compliance with standards
- EMC — electromagnetic compatibility
Why Rapidox SF6 Fixed Detection System?
For substation safety
- Continuous monitoring
- Early leak detection
- Automatic alarm
- SCADA integration
For budget savings
- Minimizing SF6 losses
- Reduced personnel costs
- Fast payback
- No fines
For environmental responsibility
- Minimizing SF6 emissions
- Compliance with the Kyoto Protocol
- Emissions reporting
- Environmental certification
Documents and Downloads
Technical specifications
| monitoring | Continuous 24/7 |
| sensitivity | From 1 ppm SF6 |
| responseTime | Less than 10 seconds |
| integration | SCADA, Modbus, Ethernet |
| alarm | Visual, audible, relay |
| power | 220V AC / 24V DC |
| operatingTemp | -20°C to +50°C |
| protection | IP65 |
Applications
Manufacturer
Cambridge Sensotec
Fixed continuous monitoring system for detecting SF6 insulating gas leaks in electrical equipment
Key specifications
- monitoring
- Continuous 24/7
- sensitivity
- From 1 ppm SF6
- responseTime
- Less than 10 seconds
- integration
- SCADA, Modbus, Ethernet
- alarm
- Visual, audible, relay
Official supplier in Kazakhstan
Related products
Rapidox SF6 6100 - Портативный газоанализатор элегаза
Портативный газоанализатор для измерения влажности, чистоты и продуктов разложения элегаза (SF6) в в...
Cambridge Sensotec
Rapidox SF6 6100 Pump Back - Газоанализатор с возвратом газа
Полностью автоматический газоанализатор элегаза с функцией возврата газа в оборудование для минимиза...
Cambridge Sensotec
Нужна консультация?
Наши специалисты помогут подобрать оптимальную конфигурацию Rapidox SF6 Fixed Detection System - Fixed Monitoring System для вашего оборудования.
Related articles
All articles →Transformer DGA at CHP: What to Add Beyond Oil Chromatography
Dissolved gas analysis (DGA) is the gold standard for transformer diagnosis but not the only tool. Companion methods at CHP plants: cooling vibration, PD ultrasound, SF₆ and O₂ on adjacent switchgear.
Integrated Monitoring of CHP Transformer Bays: Rapidox, Vibration and Ultrasound
A CHP transformer bay is transformer, breakers, cooling and switchgear in one reliability loop. How to unify Rapidox (SF₆, O₂, Clean Air), Bently on oil pumps and SDT for partial discharges in one procedure.
Oxygen Depletion in Enclosed MV Switchgear: O₂ and SF₆ Monitoring at CHP Substations
SF₆ leaks in enclosed switchgear displace oxygen below safe levels with no smell or visible warning. How to combine SF₆ and O₂ monitoring with Rapidox at combined heat and power substations.
Clean Air and Oxygen in SF₆-Free Switchgear: Monitoring at CHP During the SF₆ Transition
New dry-air (Clean Air) switchgear at CHP plants needs O₂, humidity and purity control. Rapidox 6100 Clean Air Pumpback for mixed SF₆ and SF₆-free fleets.
Vibration Monitoring of Power Transformer Cooling Auxiliaries at CHP Plants
Oil pumps, radiator fans and water-cooling pumps on step-up transformers are a hidden CHP outage source. Bently Nevada 3500/42M, Orbit DCM and 1900/65A for transformer yard auxiliaries.

SF6 Leak Detection: Sniffer vs Rapidox Analyzer — Which Tool When
Handheld SF6 sniffers find leaks fast; Rapidox analyzers measure purity, moisture and decomposition in the same sample. Choosing the right Cambridge Sensotec tool for GIS maintenance.