Supply in Kazakhstan
KEG TRK supplies measurement instrumentation solutions (Teplopribor) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.
Key features
Applications and resources
Industry solutions, landing pages and articles about Thermocouples with Standardized Output Signal
Typical tasks
- Process automation (DCS)
- Oil and gas industry
- Power generation
- Chemical industry
Description
Thermocouples with a standardized output signal have a built-in transmitter for direct connection to automation systems.
Technical specifications
- Thermocouple type: TXA, TXK, TPP, TPR
- Output signal: 4-20 mA
- Power supply: 24 V DC
- Measurement range: depends on the thermocouple type
- Protection rating: IP65
- Range setting: configurable
Advantages
- Direct connection to process automation (DCS) systems
- Remote signal transmission capability
- Explosion-proof version
- Status indication
Where it fits and how to choose
A thermocouple with a standardized output signal combines the sensing element and a transmitter in one housing; the transmitter converts the thermocouple millivolts into a 4-20 mA current signal. The transmitter compensates the cold junction itself, and the signal travels over ordinary copper cable for long distances, without compensation wires and with better immunity to interference. This version is therefore chosen for connection to a controller or process control system that has no thermocouple input, and for long runs. If the controller has a direct thermocouple input and the line is short, a plain TXA/TXK/TZhK/TNN thermocouples or TPP/TPR thermocouples is cheaper. The output range is configurable: the narrower the scale, the better the resolution, but it cannot go beyond the limits of the selected thermocouple type.
What to include in an order
For selection please specify: the thermocouple type (TXA, TXK, TPP or TPR) and the working temperature range; the required 4-20 mA scale; the ambient temperature where the electronics head is installed; the length of the immersed part and the connection type; the supply (24 V DC per the card) and the wiring scheme; explosion protection; the required output behaviour when the thermocouple breaks (to be clarified with the manufacturer).
Limits
The electronics in the head has its own permissible temperature limit: the sensing part may work at a high process temperature, but the head must be kept away from the hot surface and protected from overheating. The transmitter adds its own error to that of the thermocouple. Operation needs a current loop with a 24 V DC supply. The measurement range is set by the chosen thermocouple type, not only by the scale setting.
Related
Without a built-in transmitter: TXA/TXK/TZhK/TNN thermocouples and TPP/TPR thermocouples. If verification without stopping the process is needed, see thermocouples for verification without removal. For platinum sensors with a standardized characteristic: ТСМ/ТСП-0193. The whole section: Measuring instruments.
Technical specifications
| Thermocouple type | TXA, TXK, TPP, TPR |
| Output signal | 4-20 mA |
| Power supply | 24 V DC |
| Protection rating | IP65 |
Applications
Certificates and approvals
- Russian State Register of Measuring Instruments
- Explosion protection 1ExdIICT6
Manufacturer
Teplopribor
Thermocouples with a built-in transmitter converting to a standardized signal
Key specifications
- Thermocouple type
- TXA, TXK, TPP, TPR
- Output signal
- 4-20 mA
- Power supply
- 24 V DC
- Protection rating
- IP65
Official supplier in Kazakhstan
Need advice?
Our specialists will help you choose the optimal Thermocouples with Standardized Output Signal configuration for your equipment.