Supply in Kazakhstan
KEG TRK supplies thermal imaging inspection solutions (Hikmicro) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.
Mining equipment
Key features
Applications and resources
Industry solutions, landing pages and articles about Hikmicro HF310, HF610 and HM-TD2 high-temperature cameras — thermal cameras for up to 200 °C ambient and measurement up to 1800 °C
Typical tasks
- Furnaces, kilns and drying plants with a high ambient temperature
- Hot workshops and assemblies where an ordinary camera overheats
- Continuous temperature monitoring on a process line (box cameras in a protective enclosure)
- Sending temperature and alarms to SCADA via Modbus TCP and ONVIF
- Integration into video surveillance systems via ONVIF
Description
This group of Hikmicro cameras covers monitoring where the surroundings are too hot for an ordinary thermal camera. The HF310, HF610 and HM-TD2H67H1 bullet cameras work in an IP67 heat-resistant housing with air or liquid cooling at an ambient temperature up to 200 °C. The HM-TD2A67 high-temperature box cameras have an extended measurement range up to 1000 to 1800 °C and IP40 protection, so they are installed in a protective enclosure.

Where to use
| Task | What the camera shows |
|---|---|
| Furnaces and drying plants | working zone temperature, uneven heating |
| Hot workshops | monitoring assemblies at a high ambient temperature |
| Process lines | continuous product temperature monitoring |
| Control and video surveillance systems | temperature data and alarms over Modbus TCP and ONVIF |
Specifications
| Parameter | Value |
|---|---|
| Series | bullet HF310, HF610, HM-TD2H67H1-15/Q, HM-TD2H67H1-25/Q; box HM-TD2A67H2-7/Q, HM-TD2A67H1-15/Q, HM-TD2A67H1-25/Q |
| HF310 | 384 × 288, NETD up to 30 mK, lenses 3, 4, 8, 10 and 18 mm (field of view from 90° × 65° to 13.7° × 10.4°) |
| HF610 | 640 × 512, NETD up to 30 mK, lenses 5, 10 and 18 mm (field of view from 90° × 70.1° to 24.2° × 19.4°) |
| HF ranges | −20 to 150 °C and 0 to 650 °C, accuracy ±2 °C or ±2 % (whichever is greater) |
| HM-TD2H67H1 bullet | 640 × 512, NETD up to 35 mK; -15: 15 mm, 41.5° × 33.3°, 0 to 800 °C and 600 to 1800 °C; -25: 25 mm, 24.8° × 19.9°, up to 1800 °C |
| HM-TD2A67 box | 640 × 512, NETD up to 35 mK, 17 μm pitch; H2-7: 7 mm, 90° × 73.8°, 0 to 1000 °C; H1-15: 15 mm, 41.5° × 33.3°, 0 to 800 °C and 600 to 1800 °C; H1-25: 25 mm, 24.8° × 19.9°, 0 to 800 °C and 600 to 1800 °C |
| HM-TD2 accuracy | for objects at 100 to 1800 °C (H2-7: 100 to 1000 °C): ±2 % at ambient 18 to 25 °C; ±3 % at 25 to 50 °C |
| Protection | bullet: IP67; box: IP40 |
| Bullet operating temperature | with air or liquid cooling: 0 to 200 °C; without cooling: −20 to 60 °C (HF) or −20 to 65 °C (HM-TD2H67H1) |
| Box operating temperature | −20 to 50 °C, humidity up to 90 % |
| Cooling (manufacturer example, 20 °C inlet water) | ambient 80 °C: water flow above 0.7 l/min; 100 °C: above 1.2 l/min; 150 °C: above 1.7 l/min; 200 °C: above 3.3 l/min. Above 150 °C a front-window air curtain is also required: compressed air below 20 °C, pressure above 7 bar, flow above 120 m³/h |
| Interfaces | Ethernet RJ45 10/100/1000, RS-485, alarm input 0 to 3.3 V, alarm output (HF: relay up to 60 VDC, 1.3 A), CVBS output |
| Network (HF) | ONVIF Profile S and G, Modbus TCP, ISAPI, SDK, ISUP, GB28181, HTTPS, 802.1x; up to 20 channels |
| Power | HF: 12 VDC, up to 3.2 W; box: 10–30 VDC, up to 4.8 W |
| Weight and size | bullet: about 6520 g, 352.5 × 170.5 × 138 mm (HF); box: about 344 g, 93 × 50 × 50 mm (H2-7: 100.6 mm) |
How to choose
If the environment is hot but the object temperature does not exceed 650 °C, HF310 or HF610 is enough. If you need to measure up to 1800 °C, choose HM-TD2H67H1 (in a heat-resistant housing) or HM-TD2A67 (box, IP40, enclosure required). For furnaces without a hot ambient environment see QX310 and QX610, and for an ordinary environment QF310 and QF610.
Limits of the method
Cooling is part of the installation design and requires a supply of water or compressed air at the specified flow rates. IP40 cameras must not be used without a protective enclosure in a dusty or wet environment. The camera measures surface temperature and does not replace an equipment protection system, and explosion protection is not stated.
Supply in Kazakhstan
KEG TRK is a Hikmicro partner in Kazakhstan for thermal cameras for mining and industry. We will select a model for your tasks, prepare a quotation and arrange delivery. Price and lead time on request.
Technical specifications
| Series | bullet HF310, HF610, HM-TD2H67H1-15/Q, HM-TD2H67H1-25/Q; box HM-TD2A67H2-7/Q, HM-TD2A67H1-15/Q, HM-TD2A67H1-25/Q |
| Hf 310 | 384 × 288, NETD up to 30 mK, lenses 3, 4, 8, 10 and 18 mm (field of view from 90° × 65° to 13.7° × 10.4°) |
| Hf 610 | 640 × 512, NETD up to 30 mK, lenses 5, 10 and 18 mm (field of view from 90° × 70.1° to 24.2° × 19.4°) |
| HF ranges | −20 to 150 °C and 0 to 650 °C, accuracy ±2 °C or ±2 % (whichever is greater) |
| HM-TD2H67H1 bullet | 640 × 512, NETD up to 35 mK; -15: 15 mm, 41.5° × 33.3°, 0 to 800 °C and 600 to 1800 °C; -25: 25 mm, 24.8° × 19.9°, up to 1800 °C |
| HM-TD2A67 box | 640 × 512, NETD up to 35 mK, 17 μm pitch; H2-7: 7 mm, 90° × 73.8°, 0 to 1000 °C; H1-15: 15 mm, 41.5° × 33.3°, 0 to 800 °C and 600 to 1800 °C; H1-25: 25 mm, 24.8° × 19.9°, 0 to 800 °C and 600 to 1800 °C |
| HM-TD2 accuracy | for objects at 100 to 1800 °C (H2-7: 100 to 1000 °C): ±2 % at ambient 18 to 25 °C; ±3 % at 25 to 50 °C |
| Protection | bullet: IP67; box: IP40 |
| Bullet operating temperature | with air or liquid cooling: 0 to 200 °C; without cooling: −20 to 60 °C (HF) or −20 to 65 °C (HM-TD2H67H1) |
| Box operating temperature | −20 to 50 °C, humidity up to 90 % |
| Cooling (manufacturer example, 20 °C inlet water) | ambient 80 °C: water flow above 0.7 l/min; 100 °C: above 1.2 l/min; 150 °C: above 1.7 l/min; 200 °C: above 3.3 l/min. Above 150 °C a front-window air curtain is also required: compressed air below 20 °C, pressure above 7 bar, flow above 120 m³/h |
| Interfaces | Ethernet RJ45 10/100/1000, RS-485, alarm input 0 to 3.3 V, alarm output (HF: relay up to 60 VDC, 1.3 A), CVBS output |
| Network (HF) | ONVIF Profile S and G, Modbus TCP, ISAPI, SDK, ISUP, GB28181, HTTPS, 802.1x; up to 20 channels |
| Power | HF: 12 VDC, up to 3.2 W; box: 10–30 VDC, up to 4.8 W |
| Weight and size | bullet: about 6520 g, 352.5 × 170.5 × 138 mm (HF); box: about 344 g, 93 × 50 × 50 mm (H2-7: 100.6 mm) |
Applications
Manufacturer
Hikmicro
Fixed network cameras for hot environments: HF310 and HF610 bullet cameras in an IP67 heat-resistant housing with air or liquid cooling work at ambient temperatures up to 200 °C; HM-TD2A67 box cameras (IP40) measure up to 1000 to 1800 °C.
Key specifications
- Series
- bullet HF310, HF610, HM-TD2H67H1-15/Q, HM-TD2H67H1-25/Q; box HM-TD2A67H2-7/Q, HM-TD2A67H1-15/Q, HM-TD2A67H1-25/Q
- Hf 310
- 384 × 288, NETD up to 30 mK, lenses 3, 4, 8, 10 and 18 mm (field of view from 90° × 65° to 13.7° × 10.4°)
- Hf 610
- 640 × 512, NETD up to 30 mK, lenses 5, 10 and 18 mm (field of view from 90° × 70.1° to 24.2° × 19.4°)
- HF ranges
- −20 to 150 °C and 0 to 650 °C, accuracy ±2 °C or ±2 % (whichever is greater)
- HM-TD2H67H1 bullet
- 640 × 512, NETD up to 35 mK; -15: 15 mm, 41.5° × 33.3°, 0 to 800 °C and 600 to 1800 °C; -25: 25 mm, 24.8° × 19.9°, up to 1800 °C
Official supplier in Kazakhstan
Related products

Hikmicro QX310 and QX610 — thermal cameras for furnace monitoring up to 2000 °C
Fixed network thermal cameras for furnace monitoring: 384 × 288 (QX310) or 640 × 512 (QX610) detector, measurement up to 2000 °C, IP67, 10–30 VDC power, Ethernet, RS-485 (Modbus).
- QX310; QX610
- QX310: 384 × 288; QX610: 640 × 512

Hikmicro QF310 and QF610 — focus-free network thermal box cameras
Compact network thermal cameras with fixed focus: 384 × 288 (QF310) or 640 × 512 (QF610) detector, several lenses, ONVIF, Modbus TCP, USB-C (UVC), measurement up to 650 °C, weight about 160 to 170 g.
- QF310; QF610
- QF310: 384 × 288; QF610: 640 × 512

Hikmicro PD1, PS2 and PD2 — fixed pyrometers for temperature measurement from 150 to 3200 °C
Fixed single-colour and two-colour pyrometers: PD1 series (500 to 3200 °C, laser sighting, display, IP65) and compact PS2 and PD2 (150 to 3200 °C, IP66), 4–20 mA analogue output, RS-485, Modbus, TCP/IP.
- PD110: 1000 to 3200 °C; PD111: 1000 to 3200 °C; PD120: 500 to 1800 °C; PD121: 500 to 1800 °C; two-colour, spectrum 0.8 to 1.08 μm
- PS210: 500 to 1800 °C (0.8 to 1.08 μm); PS220: 150 to 1600 °C (1.45 to 2.2 μm); PS230: 700 to 3200 °C (0.8 to 1.08 μm); single-colour
Need advice?
Our specialists will help you choose the optimal Hikmicro HF310, HF610 and HM-TD2 high-temperature cameras — thermal cameras for up to 200 °C ambient and measurement up to 1800 °C configuration for your equipment.