Supply in Kazakhstan
KEG TRK supplies thermal imaging inspection solutions (Hikmicro) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.
Mining equipment
Key features
Applications and resources
Industry solutions, landing pages and articles about Hikmicro PD1, PS2 and PD2 — fixed pyrometers for temperature measurement from 150 to 3200 °C
Typical tasks
- Measuring temperature in furnaces, melting and heating installations
- Continuous non-contact temperature monitoring of product and melt
- Sending temperature to the control system via a 4–20 mA loop and Modbus
- Over-temperature alarms on a relay
- Monitoring areas with a high ambient temperature when cooling is used
Description
A pyrometer measures the temperature of an object from its thermal radiation without contact and without an image: it shows one value for the spot it observes. Hikmicro makes two lines of fixed pyrometers. The PD1 series with laser sighting, a display and an eyepiece for two-colour measurement in the 500 to 3200 °C range. The compact PS2 (single-colour) and PD2 (two-colour) series with a range from 150 to 3200 °C. 4–20 mA, Modbus and TCP/IP outputs let the pyrometer connect to a control system.

Where to use
| Task | What the camera shows |
|---|---|
| Furnaces and heating installations | working zone temperature |
| Melting and heat treatment processes | melt and workpiece temperature |
| Lines with a high ambient temperature | spot monitoring when cooling is used |
| Automatic control systems | 4–20 mA loop, Modbus and TCP/IP |
Specifications
| Parameter | Value |
|---|---|
| PD1 series | PD110: 1000 to 3200 °C; PD111: 1000 to 3200 °C; PD120: 500 to 1800 °C; PD121: 500 to 1800 °C; two-colour, spectrum 0.8 to 1.08 μm |
| PS2 series | PS210: 500 to 1800 °C (0.8 to 1.08 μm); PS220: 150 to 1600 °C (1.45 to 2.2 μm); PS230: 700 to 3200 °C (0.8 to 1.08 μm); single-colour |
| PD2 series | PD210: 600 to 1800 °C (0.8 to 1.08 μm); PD220: 300 to 1600 °C (1.3 to 1.7 μm); PD230: 700 to 3200 °C (0.8 to 1.08 μm); two-colour |
| PD1: optics and focus | PD110 and PD120: focus 0.3 to 0.6 m; PD111 and PD121: focus 0.6 m to infinity; D:S 300:1 (PD110, PD111) and 100:1 (PD120, PD121); spot from 1 mm (PD110) to 6 mm (PD121) |
| PS2 and PD2: optics | focus from 0.3 m to infinity; D:S 100:1 (PS210, PS220, PD210, PD220), 200:1 (PS230, PD230); spot 3 mm, 1.5 mm for PS230 and PD230; sighting on the display |
| PD1 accuracy | ±(0.3 % × T + 1) °C, repeatability ±(0.1 % × T + 1) °C, where T is the measured temperature |
| PS2 and PD2 accuracy | PS2: ±(0.3 % × T + 2) °C; PD2: ±(0.5 % × T + 2) °C (in the main part of the range, the tolerance is wider near the lower limit); at ambient 23 ± 5 °C and emissivity 1 |
| Reading resolution | 0.1 °C |
| Response time | PD1: 1 ms; PS2 and PD2: 10 ms |
| Emissivity | 0.100 to 1.100; slope 0.850 to 1.150 (two-colour) |
| Signal processing | averaging, temperature filter, peak and valley hold |
| Outputs | analogue 4–20 mA / 0–20 mA (16-bit, load up to 400 Ω); RS-485 Modbus RTU, Modbus TCP; TCP/IP; relay output (PD1: optocoupler isolation, PNP 24 V) |
| Alarms (PS2, PD2) | temperature, ambient temperature, dirt, FSMC, 4–20 mA, relay, I/O |
| Display and sighting | PD1: 2.4" OLED 600 × 448, laser, eyepiece; PS2 and PD2: OLED 128 × 32, no laser |
| Protection | PD1: IP65; PS2 and PD2: IP66 |
| Operating temperature | without cooling: PD1 −20 to 65 °C, PS2 and PD2 0 to 65 °C; with air and water cooling accessories up to 300 °C |
| Power | PD1: 15–30 VDC, up to 10 W; PS2 and PD2: 10–30 VDC, up to 5 W |
| Weight and size | PD1: about 1780 g, 87.8 × 92.4 × 229.5 mm; PS2 and PD2: about 680 g, diameter 52.4 mm, length 148.7 mm |
How to choose
If you need to see the temperature distribution and not a single value, use the QX or HF/HM-TD2 thermal cameras, and for periodic rounds the handheld G. We choose the pyrometer model by range, distance to the object and spot size: PD110 and PD111 for high temperatures from 1000 °C, PS220 and PD220 for the low end of the range from 150 and 300 °C.
Limits of the method
A pyrometer shows the average temperature within the observed spot, and the spot must be filled entirely by the object. The result is affected by emissivity, dust, smoke and contamination of the optics. A permanent installation needs protection from contamination and cooling at a high ambient temperature. Explosion protection is not stated.
Supply in Kazakhstan
KEG TRK is a Hikmicro partner in Kazakhstan for thermal cameras for mining and industry. We will select a model for your tasks, prepare a quotation and arrange delivery. Price and lead time on request.
Technical specifications
| PD1 series | PD110: 1000 to 3200 °C; PD111: 1000 to 3200 °C; PD120: 500 to 1800 °C; PD121: 500 to 1800 °C; two-colour, spectrum 0.8 to 1.08 μm |
| PS2 series | PS210: 500 to 1800 °C (0.8 to 1.08 μm); PS220: 150 to 1600 °C (1.45 to 2.2 μm); PS230: 700 to 3200 °C (0.8 to 1.08 μm); single-colour |
| PD2 series | PD210: 600 to 1800 °C (0.8 to 1.08 μm); PD220: 300 to 1600 °C (1.3 to 1.7 μm); PD230: 700 to 3200 °C (0.8 to 1.08 μm); two-colour |
| PD1: optics and focus | PD110 and PD120: focus 0.3 to 0.6 m; PD111 and PD121: focus 0.6 m to infinity; D:S 300:1 (PD110, PD111) and 100:1 (PD120, PD121); spot from 1 mm (PD110) to 6 mm (PD121) |
| PS2 and PD2: optics | focus from 0.3 m to infinity; D:S 100:1 (PS210, PS220, PD210, PD220), 200:1 (PS230, PD230); spot 3 mm, 1.5 mm for PS230 and PD230; sighting on the display |
| PD1 accuracy | ±(0.3 % × T + 1) °C, repeatability ±(0.1 % × T + 1) °C, where T is the measured temperature |
| PS2 and PD2 accuracy | PS2: ±(0.3 % × T + 2) °C; PD2: ±(0.5 % × T + 2) °C (in the main part of the range, the tolerance is wider near the lower limit); at ambient 23 ± 5 °C and emissivity 1 |
| Reading resolution | 0.1 °C |
| Response time | PD1: 1 ms; PS2 and PD2: 10 ms |
| Emissivity | 0.100 to 1.100; slope 0.850 to 1.150 (two-colour) |
| Signal processing | averaging, temperature filter, peak and valley hold |
| Outputs | analogue 4–20 mA / 0–20 mA (16-bit, load up to 400 Ω); RS-485 Modbus RTU, Modbus TCP; TCP/IP; relay output (PD1: optocoupler isolation, PNP 24 V) |
| Alarms (PS2, PD2) | temperature, ambient temperature, dirt, FSMC, 4–20 mA, relay, I/O |
| Display and sighting | PD1: 2.4" OLED 600 × 448, laser, eyepiece; PS2 and PD2: OLED 128 × 32, no laser |
| Protection | PD1: IP65; PS2 and PD2: IP66 |
| Operating temperature | without cooling: PD1 −20 to 65 °C, PS2 and PD2 0 to 65 °C; with air and water cooling accessories up to 300 °C |
| Power | PD1: 15–30 VDC, up to 10 W; PS2 and PD2: 10–30 VDC, up to 5 W |
| Weight and size | PD1: about 1780 g, 87.8 × 92.4 × 229.5 mm; PS2 and PD2: about 680 g, diameter 52.4 mm, length 148.7 mm |
Applications
Manufacturer
Hikmicro
Fixed single-colour and two-colour pyrometers: PD1 series (500 to 3200 °C, laser sighting, display, IP65) and compact PS2 and PD2 (150 to 3200 °C, IP66), 4–20 mA analogue output, RS-485, Modbus, TCP/IP.
Key specifications
- PD1 series
- PD110: 1000 to 3200 °C; PD111: 1000 to 3200 °C; PD120: 500 to 1800 °C; PD121: 500 to 1800 °C; two-colour, spectrum 0.8 to 1.08 μm
- PS2 series
- PS210: 500 to 1800 °C (0.8 to 1.08 μm); PS220: 150 to 1600 °C (1.45 to 2.2 μm); PS230: 700 to 3200 °C (0.8 to 1.08 μm); single-colour
- PD2 series
- PD210: 600 to 1800 °C (0.8 to 1.08 μm); PD220: 300 to 1600 °C (1.3 to 1.7 μm); PD230: 700 to 3200 °C (0.8 to 1.08 μm); two-colour
- PD1: optics and focus
- PD110 and PD120: focus 0.3 to 0.6 m; PD111 and PD121: focus 0.6 m to infinity; D:S 300:1 (PD110, PD111) and 100:1 (PD120, PD121); spot from 1 mm (PD110) to 6 mm (PD121)
- PS2 and PD2: optics
- focus from 0.3 m to infinity; D:S 100:1 (PS210, PS220, PD210, PD220), 200:1 (PS230, PD230); spot 3 mm, 1.5 mm for PS230 and PD230; sighting on the display
Official supplier in Kazakhstan
Related products

Hikmicro QX310 and QX610 — thermal cameras for furnace monitoring up to 2000 °C
Fixed network thermal cameras for furnace monitoring: 384 × 288 (QX310) or 640 × 512 (QX610) detector, measurement up to 2000 °C, IP67, 10–30 VDC power, Ethernet, RS-485 (Modbus).
- QX310; QX610
- QX310: 384 × 288; QX610: 640 × 512

Hikmicro HF310, HF610 and HM-TD2 high-temperature cameras — thermal cameras for up to 200 °C ambient and measurement up to 1800 °C
Fixed network cameras for hot environments: HF310 and HF610 bullet cameras in an IP67 heat-resistant housing with air or liquid cooling work at ambient temperatures up to 200 °C; HM-TD2A67 box cameras (IP40) measure up to 1000 to 1800 °C.
- bullet HF310, HF610, HM-TD2H67H1-15/Q, HM-TD2H67H1-25/Q; box HM-TD2A67H2-7/Q, HM-TD2A67H1-15/Q, HM-TD2A67H1-25/Q
- 384 × 288, NETD up to 30 mK, lenses 3, 4, 8, 10 and 18 mm (field of view from 90° × 65° to 13.7° × 10.4°)

Hikmicro G series — industrial thermal cameras up to 640 × 480 and 2000 °C
Rugged industrial thermal cameras G31, G41, G41H, G61 and G61H: IR detector up to 640 × 480, autofocus and laser distance meter, add-on lenses, H versions up to 2000 °C, three interchangeable batteries for up to 12 hours.
- G31, G41, G41H, G61, G61H
- G31 — 384 × 288; G41 and G41H — 480 × 360; G61 and G61H — 640 × 480
Need advice?
Our specialists will help you choose the optimal Hikmicro PD1, PS2 and PD2 — fixed pyrometers for temperature measurement from 150 to 3200 °C configuration for your equipment.