Autoclave condition monitoring
Autoclaves and sterilizers: drives, seals, vacuum pumps — Artesis, SDT. KEG TRK.

Autoclaves and sterilizers
Autoclaves are GMP-critical: vacuum/condensate pump, fan or seal failure breaks the sterilization cycle and validation. Diagnostics from the technical zone avoid cleanroom intrusion.
Monitor vacuum/condensate pumps, recirculation fans, door seals/valves with ultrasound, damper drives. Artesis from the tech zone + SDT on seals/bearings.
See capsule fillers, AHU, boilers.
SDT for autoclave condition monitoring monitoring
SDT Ultrasound instruments deliver full acoustic condition monitoring in dusty, noisy plants
Artesis — continuous drive monitoring
Artesis EMCM analyzes motor current and voltage without sensors on the machine
Bently Nevada — vibration diagnostics
Permanent and distributed systems for critical mining assets
Olympus — thickness gauging and videoscopes
When vibration finds a symptom, Olympus confirms metal, weld or internal cavity condition

Olympus 39DL PLUS — ultrasonic thickness gauge
General-purpose Olympus (Evident) ultrasonic thickness gauge, successor to the 38DL PLUS: 0.08–635 mm, up to 60 Hz update, single and dual element transducers, THRU-COAT, Echo-to-Echo, B-scan, up to 792,832 readings, IP67, 0.83 kg.

Olympus IPLEX One — 10th-generation videoscope
The 10th generation of Olympus (Evident) IPLEX videoscopes: Plus, Expert and Prime tiers on one hardware platform, Swoptix optics without withdrawing the probe, 3DAssist, 10.1" 1100-nit tablet, four light sources, up to 360 min runtime.
Ion Science — SF6, VOC and industrial leaks
Portable and fixed detectors for SF6 at substations, VOC on chemical sites and refrigerant leaks in HVAC

Ion Science Tiger XT — handheld PID detector for volatile organic compounds
Intrinsically safe Ion Science photoionisation detector for over 750 volatile organic compounds: 1 ppb to 20,000 ppm, T90 under 2 s, Fence Electrode technology against humidity and contamination, up to 24 h runtime and 120,000 logged readings.

Ion Science Panther PRO — helium, hydrogen and refrigerant leak detector
Portable leak detector with a micro thermal conductivity sensor (MTCD): helium from 5×10⁻⁶ cc/s, hydrogen from 3.8×10⁻⁶ cc/s, refrigerants via the built-in gas table. 1 s response, up to 20 h runtime, 10 days of logging, Bluetooth.
Solutions and resources
Products, related applications and articles for Autoclave condition monitoring
Recommended products
Related applications
FAQ: Autoclave condition monitoring monitoring
Need advice?
Our specialists will help you choose the optimal Autoclave condition monitoring configuration for your equipment.