Aeration tank monitoring
Aeration tank equipment diagnostics: Artesis current-based monitoring of blower and mixer motors, SDT ultrasound for bearings and lubrication.

Aeration tanks
Aeration tanks anchor biological treatment. Aerator, mixer or blower failure hits DO and effluent quality immediately. Tie drive mechanics to air delivery.
Monitor aerators/mixers, air blowers/compressors, RAS pumps, bearings and drive current via Artesis + SDT. Continuous Artesis on large drives + SDT rounds. Correlate with aerators and clarifiers.
See aerators, clarifiers.
Falling DO with a “healthy” aerator current points to air leaks or diffuser fouling — ultrasound the air main.
SDT for aeration tank monitoring monitoring
SDT Ultrasound instruments deliver full acoustic condition monitoring in dusty, noisy plants
Artesis — continuous drive monitoring
Artesis EMCM analyzes motor current and voltage without sensors on the machine
Bently Nevada — vibration diagnostics
Permanent and distributed systems for critical mining assets
Olympus — thickness gauging and videoscopes
When vibration finds a symptom, Olympus confirms metal, weld or internal cavity condition

Olympus 39DL PLUS — ultrasonic thickness gauge
General-purpose Olympus (Evident) ultrasonic thickness gauge, successor to the 38DL PLUS: 0.08–635 mm, up to 60 Hz update, single and dual element transducers, THRU-COAT, Echo-to-Echo, B-scan, up to 792,832 readings, IP67, 0.83 kg.

Olympus IPLEX One — 10th-generation videoscope
The 10th generation of Olympus (Evident) IPLEX videoscopes: Plus, Expert and Prime tiers on one hardware platform, Swoptix optics without withdrawing the probe, 3DAssist, 10.1" 1100-nit tablet, four light sources, up to 360 min runtime.
Ion Science — SF6, VOC and industrial leaks
Portable and fixed detectors for SF6 at substations, VOC on chemical sites and refrigerant leaks in HVAC

Ion Science Tiger XT — handheld PID detector for volatile organic compounds
Intrinsically safe Ion Science photoionisation detector for over 750 volatile organic compounds: 1 ppb to 20,000 ppm, T90 under 2 s, Fence Electrode technology against humidity and contamination, up to 24 h runtime and 120,000 logged readings.

Ion Science Falco 2 — fixed PID VOC detector
Flameproof fixed photoionisation detector for over 700 volatile organic compounds: diffused or pumped, ranges from 0–10 to 0–3000 ppm, a TAC version for benzene, 4–20 mA, RS485 Modbus and two relays.
Solutions and resources
Products, related applications and articles for Aeration tank monitoring
Recommended products
Related applications
FAQ: Aeration tank monitoring monitoring
Need advice?
Our specialists will help you choose the optimal Aeration tank monitoring configuration for your equipment.