A large fan or induced-draft fan has a rotor weighing 2–15 tonnes, running in journal or anti-friction bearings at 400–1500 rpm. A casing accelerometer or Velomitor on the pedestal shows overall structural vibration but does not directly measure shaft position in the bearing clearance. Yet clearance is the first parameter to change with axial rub, thrust bearing damage, loose impeller retention and blade cracks.