CrysoundCrysound

Crysound CRY2624 ATEX — Acoustic Camera for Explosive Zones

Explosion-proof Crysound CRY2624 ATEX acoustic camera (Ex ic IIC T5 Gc) with 128 MEMS sensors: leaks and partial discharge on oil & gas and chemical sites. Range up to 120 metres. Price on request.

Crysound CRY2624 ATEX — Acoustic Camera for Explosive Zones — Crysound
Crysound CRY2624 ATEX — Acoustic Camera for Explosive Zones

Supply in Kazakhstan

KEG TRK supplies ultrasonic diagnostics solutions (Crysound) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.

Key features

ATEX explosion protection: Ex ic IIC T5 Gc
128 digital MEMS sensors
Detection range up to 120 metres
Partial-discharge detection (PRPD)
Visualisation of gas and air leaks
IP54 protection rating

Industry solutions, landing pages and articles on Crysound CRY2624 ATEX — Acoustic Camera for Explosive Zones

Typical tasks

  • Gas leaks in explosive zones
  • Oil & gas and chemical sites
  • Partial discharge at substations

Overview

Crysound CRY2624 ATEX is the explosion-proof version of the CRY2600 series, certified to ATEX (Ex ic IIC T5 Gc) for use in zones with a potentially explosive atmosphere. The camera combines leak detection and partial-discharge detection (with PRPD maps) and is designed for the oil & gas and chemical industries.

An array of 128 MEMS sensors and a range of up to 120 metres allow safe inspection of installations without stopping production.

Key features

  • ATEX explosion protection — Ex ic IIC T5 Gc, approved for work in explosive zones.
  • 128 MEMS sensors and a range of up to 120 m — precise localisation at distance.
  • Partial discharge + PRPD — diagnostics of high-voltage equipment.
  • Gas leak detection — critical for oil & gas and chemicals.
  • IP54 — protection against dust and splashes.

Applications

  • Detecting gas leaks at oil & gas and chemical sites in explosive zones
  • Partial-discharge detection at substations and in switchgear
  • Preventive diagnostics of process installations

Supply

The CRY2624 ATEX is supplied in Kazakhstan through the SDT Ultrasound Solutions network. KEG TRK is an official SDT partner. Price on request.

Manufacturer

Crysound

Crysound

Explosion-proof Crysound CRY2624 ATEX acoustic camera (Ex ic IIC T5 Gc) with 128 MEMS sensors: leaks and partial discharge on oil & gas and chemical sites. Range up to 120 metres. Price on request.

Key specifications

Certification
ATEX, Ex ic IIC T5 Gc
Microphones
128 MEMS sensors
Frequency range
2–48 kHz
Range
up to 120 m
Partial discharge
Yes, with PRPD maps

Official supplier in Kazakhstan

Need advice?

Our specialists will help you choose the optimal Crysound CRY2624 ATEX — Acoustic Camera for Explosive Zones configuration for your equipment.

Related articles

All articles →
What compressed air leaks cost: a step-by-step calculation
Article

What compressed air leaks cost: a step-by-step calculation

Leak cost = air flow × operating hours × compressor specific energy × tariff. A flow table by orifice diameter and pressure, a worked example and how to use your own tariff.

How to test a steam trap: ultrasound and temperature
Article

How to test a steam trap: ultrasound and temperature

A steam trap is tested with two readings: temperature finds blocked traps, ultrasound before and after the trap finds steam blow-through. Signs by trap type, the procedure and steam losses.

Ultrasound at low speeds: how to diagnose a gearbox running at 0.1 rpm
Case study

Ultrasound at low speeds: how to diagnose a gearbox running at 0.1 rpm

Vibration analysis below 10 rpm often leads to wrong conclusions. A real case: a broken gear tooth at 2.95 rpm caught by the SDT340 where the vibration FFT could not help.

Safe Remote Inspection and Precision Bearing Lubrication in Hazardous and Clean Areas
Article

Safe Remote Inspection and Precision Bearing Lubrication in Hazardous and Clean Areas

How SDT acoustic cameras SonaVu and Crysound CRY8120 ATEX, together with the LUBExpert system, let you service equipment in pharmaceutical cleanrooms and hazardous areas without entering the zone or stopping production.

Partial Discharge in Switchgear and Substations: Hearing a Breakdown Before It Happens
Article

Partial Discharge in Switchgear and Substations: Hearing a Breakdown Before It Happens

Corona, tracking and partial discharge silently destroy switchgear, transformer and cable-joint insulation for months before a flashover. How ultrasound and UV inspection catch insulation defects from a safe distance.

Ultrasound Inspection: A Beginner's Guide
Tutorial

Ultrasound Inspection: A Beginner's Guide

How ultrasound condition monitoring works, what it finds across SDT's eight application areas, which instrument to choose and how to build an inspection programme.