Condensate pump monitoring
Turbine-hall condensate pumps: NPSH, bearings — Bently, Artesis, SDT. KEG TRK.

Condensate extraction pumps
CEPs run near the NPSH edge: low condenser suction makes cavitation a standing risk. Without acoustic and vibration trends, failures look “sudden”.
Watch ultrasound growth on bearings/casing, motor current shifts with vacuum loss, axial position on large CEPs, and seal health. Separate pump vs turbine monitoring avoids false hypotheses.
Stack: Artesis e-MCM + SDT340 + Bently 3500 when needed.
See boiler feed pumps.
Olympus — NDT and remote visual inspection
- Thickness gauging — casings, piping and vessels (39DL PLUS)
- Videoscopes — cavities and flow paths on outages (IPLEX One)
Catalogs: NDT · endoscopes · Olympus brand.
SDT for condensate pump monitoring monitoring
SDT Ultrasound instruments deliver full acoustic condition monitoring in dusty, noisy plants
Bently Nevada — vibration diagnostics
Permanent and distributed systems for critical mining assets

3500/42M — 3500 monitoring module
4-channel proximitor/seismic monitor for critical turbomachinery and API 670 protection

SCOUT Series — portable vibration analyzers
Portable data collectors and analyzers for equipment diagnostics

200150 Series — IEPE accelerometer
IEPE piezoelectric accelerometers for industrial vibration and bearing health measurement
Olympus — thickness gauging and videoscopes
When vibration finds a symptom, Olympus confirms metal, weld or internal cavity condition

Olympus 39DL PLUS — ultrasonic thickness gauge
Flagship corrosion and precision thickness gauge with Wi-Fi, Bluetooth and up to 60 Hz scanning

Olympus 38DL PLUS — ultrasonic thickness gauge
High-precision ultrasonic thickness gauge for corrosion monitoring and material thickness measurement

Olympus IPLEX One — industrial videoscope platform
10th-generation IPLEX software platform with Swoptix, 3DAssist and Plus/Expert/Prime tiers
Solutions and resources
Products, related applications and articles for Condensate pump monitoring
Recommended products
Related applications
FAQ: Condensate pump monitoring monitoring
Нужна консультация?
Наши специалисты помогут подобрать оптимальную конфигурацию Condensate pump monitoring для вашего оборудования.