Case: Greek Paper Mill — LUBEChecker Exposed Plant-Wide Over-Greasing
Bearings lasted a month instead of years. Clearance changes did not help. A REA Hellas audit with LUBEChecker showed every bearing was over-lubricated on a calendar. How SDT ultrasound stopped the failures.

Source. SDT Ultrasound case: Greek paper mill with REA Hellas. Product photos from SDT / LUBEChecker.
Problem
Bearings failed after about one month. Consultants switched to tighter clearances — failures continued at the same rate. Symptom treated, root cause missed.
Breakthrough
The mill bought a LUBEChecker and ran an on-site lubrication audit.


Finding: every bearing was over-greased on a calendar — a time-based failure mode.

Changes
Condition-based greasing by ultrasonic friction; stop when the signal bottoms out; roadmap to SDT340 and LUBExpert.
See cement-plant LUBExpert case and 70% over-grease study. KEG TRK — demo.
Equipment in this article
LUBEChecker - Контроль смазки подшипников
Специализированный детектор для контроля смазки подшипников в реальном времени
LUBExpert - Система управления смазкой подшипников
Управление программой смазки подшипников с базой данных, Shopping List и Work Or...
SDT340 - Продвинутый ультразвуковой детектор
Самый продвинутый ультразвуковой детектор для сбора, анализа и трендирования дан...
Read also
7/22/2026
LUBExpert Case: Greasing a Cement-Plant Fan Exposed Bearing Failure Early
SDT cement-plant case: calendar greasing dosed 50 g every two weeks. LUBExpert Static cut dose to ~16/14 g and, with rising friction plus vibration, caught cooling-fan bearing failure before unplanned downtime.
7/22/2026
ON-GUARD Case: Auto-Lube on a Pulp Mill Pump Caught BPFO Early
Canadian pulp & paper: LUBExpert ON-GUARD watched pump friction RMS, alarmed on NDE, LUBExpert confirmed BPFO. No blind greasing — replacement scheduled on a planned shutdown.
7/22/2026
Ultrasonic Bearing Grease Management with SDT: 70% of Points Over-Greased
SDT multi-plant studies: switching from grease formulas to LUBExpert found ~70% of bearings over-lubricated, 15% under, only 15% correct. How ultrasound sets dose and interval.