ON-GUARD Case: Auto-Lube on a Pulp Mill Pump Caught BPFO Early
Canadian pulp & paper: LUBExpert ON-GUARD watched pump friction RMS, alarmed on NDE, LUBExpert confirmed BPFO. No blind greasing — replacement scheduled on a planned shutdown.

Source. SDT Ultrasound case from a Canadian pulp & paper site.
Setup
LUBExpert ON-GUARD on the pump motor: CONMONSense on the grease line (DE) and in the NDE housing, plus pressure gauge.


Event
ON-GUARD raised Suspected Bearing Failure on NDE. Follow-up dynamic data with LUBExpert confirmed BPFO. Repair went to the next planned outage.

Architecture overview: ON-GUARD article. KEG TRK — contact.
Equipment in this article
LUBExpert ON-GUARD - Automatic Bearing Lubrication System
Smart condition-based ultrasonic lubrication system with the LUBrain algorithm f...
LUBExpert - Bearing Lubrication Management System
Bearing lubrication programme management with a parts database, Shopping List an...
SDT340 - Advanced Ultrasound Detector
The most advanced ultrasound detector for collecting, analysing and trending dat...
Read also
7/22/2026
Case: Greek Paper Mill — LUBEChecker Exposed Plant-Wide Over-Greasing
Bearings lasted a month instead of years. Clearance changes did not help. A REA Hellas audit with LUBEChecker showed every bearing was over-lubricated on a calendar. How SDT ultrasound stopped the failures.
7/22/2026
LUBExpert Case: Greasing a Cement-Plant Fan Exposed Bearing Failure Early
SDT cement-plant case: calendar greasing dosed 50 g every two weeks. LUBExpert Static cut dose to ~16/14 g and, with rising friction plus vibration, caught cooling-fan bearing failure before unplanned downtime.
7/25/2026
Plant Lubrication Point Map: How to Build It and Which KPIs to Track
How to build a lubrication point map: asset inventory, grease grade and dose ceiling, criticality, routes, and program KPIs. Without a map, “scheduled greasing” stays chaos.