KEG TRK supplies Rapidox gas analysis solutions (Cambridge Sensotec) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.
Key features
Applications and resources
Industry solutions, landing pages and articles on Rapidox 2100 — in-process oxygen analyser
Typical tasks
- Transformer headspace O₂ monitoring
- Power transformer nitrogen blanketing
- CHP furnaces and boilers
- GIS vacuum processes
- Metallurgy and cement
Description
Rapidox 2100 — in-process oxygen analyser (RX2100-Z) — Cambridge Sensotec Rapidox gas analyser for power transformers, switchgear, GIS and CHP plants. Supplied by KEG TRK in Kazakhstan.
Key features
- 10⁻²⁰ ppm – 30% O₂ zirconia
- Sensor cable up to 25 m
- Type K thermocouple 0–1250°C
- Optional H₂O, pressure, vacuum
- IP65 enclosure, panel mount
Applications
- Transformer headspace O₂ monitoring
- Power transformer nitrogen blanketing
- CHP furnaces and boilers
- GIS vacuum processes
- Metallurgy and cement
Technical specifications
| Parameter | Value |
|---|---|
| O₂ range | 10⁻²⁰ ppm – 30% (zirconia); 0–100% (electrochemical) |
| Sample temperature | up to 650 °C |
| Thermocouple | Type K, 0–1250°C |
| Sensor cable | 2 m standard, up to 25 m |
| Outputs | 0–5 V, 4–20 mA, RS232/Modbus/Ethernet |
| Power supply | 90–260 V AC |
Why Rapidox from KEG TRK?
- Official Cambridge Sensotec supplier in Kazakhstan
- Configuration for transformers, GIS, CHP and switchgear
- Staff training and technical support
- Integration with existing substation monitoring systems
Technical specifications
| O₂ range | 10⁻²⁰ ppm – 30% (zirconia); 0–100% (electrochemical) |
| Sample temperature | up to 650 °C |
| Thermocouple | Type K, 0–1250°C |
| Sensor cable | 2 m standard, up to 25 m |
| Outputs | 0–5 V, 4–20 mA, RS232/Modbus/Ethernet |
| Power supply | 90–260 V AC |
Applications
Manufacturer
Cambridge Sensotec
Zirconia O₂ analyser with remote sensor to 650°C and Type K thermocouple for transformers and furnaces
Key specifications
- O₂ range
- 10⁻²⁰ ppm – 30% (zirconia); 0–100% (electrochemical)
- Sample temperature
- up to 650 °C
- Thermocouple
- Type K, 0–1250°C
- Sensor cable
- 2 m standard, up to 25 m
- Outputs
- 0–5 V, 4–20 mA, RS232/Modbus/Ethernet
Official supplier in Kazakhstan
Related products
Rapidox 2100-OEM-RSB
Compact 24 V OEM zirconia O₂ module for transformer monitoring systems
Cambridge Sensotec
Rapidox 2112 — 15-channel O₂ multiplex
Multiplexer for up to 15 oxygen sample points on large transformers, furnaces and GIS
Cambridge Sensotec
Rapidox 1100 — oxygen analyser
Versatile O₂ analyser with zirconia, electrochemical or optical sensor for ppm and percent measureme...
Cambridge Sensotec
Need advice?
Our specialists will help you choose the optimal Rapidox 2100 — in-process oxygen analyser configuration for your equipment.
Related articles
All articles →Conservator and Oxygen: CHP Oil Diagnostics Without Opening the Tank
Membrane, breather and conservator sealing directly affect oil oxygen. Rapidox 1100 headspace practice on CHP power transformers.
Nitrogen Blanket on CHP Auxiliary Transformers: Continuous Rapidox 2100 Monitoring
Auxiliary and station-service transformers often use nitrogen over oil. How Rapidox 2100 continuous O₂ monitoring and Rapidox 1100 walk-downs prevent accelerated insulation ageing.
Field Gas Screening Before Laboratory DGA on Transformers
How to run a transformer fleet walk-down with Rapidox 1100 and 3100: DGA prioritisation, protocols and traffic-light decisions for CHP and plant substations.