Rapidox 1100 — oxygen analyser

Versatile O₂ analyser with zirconia, electrochemical or optical sensor for ppm and percent measurements

Rapidox 1100 — oxygen analyser — Cambridge Sensotec
Rapidox 1100 — oxygen analyser

Supply in Kazakhstan

KEG TRK supplies Rapidox gas analysis solutions (Cambridge Sensotec) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.

Key features

0.5 ppm – 30% O₂ zirconia range
Diaphragm pump or vacuum ejector
RS232/Modbus RTU, 4–20 mA
N₂/Ar background calibration
Programmable alarm relays

Industry solutions, landing pages and articles on Rapidox 1100 — oxygen analyser

Typical tasks

  • Power transformer nitrogen blanketing
  • Switchgear and GIS inert gas monitoring
  • CHP/boiler combustion control
  • Reflow and heat-treatment ovens
  • Energy laboratory QA

Description

Rapidox 1100 — oxygen analyser (RX1100-Z) — Cambridge Sensotec Rapidox gas analyser for power transformers, switchgear, GIS and CHP plants. Supplied by KEG TRK in Kazakhstan.

Key features

  • 0.5 ppm – 30% O₂ zirconia range
  • Diaphragm pump or vacuum ejector
  • RS232/Modbus RTU, 4–20 mA
  • N₂/Ar background calibration
  • Programmable alarm relays

Applications

  • Power transformer nitrogen blanketing
  • Switchgear and GIS inert gas monitoring
  • CHP/boiler combustion control
  • Reflow and heat-treatment ovens
  • Energy laboratory QA

Technical specifications

Parameter Value
O₂ range 0.5 ppm – 30% (zirconia); 0.1 ppm – 100% (electrochemical/optical)
Accuracy ±1% of reading
Outputs 0–10 V, 4–20 mA, RS232/Modbus
Pump 0–1.2 l/min (optional)
Power supply 90–260 V AC
Display OLED 20×4

Why Rapidox from KEG TRK?

  • Official Cambridge Sensotec supplier in Kazakhstan
  • Configuration for transformers, GIS, CHP and switchgear
  • Staff training and technical support
  • Integration with existing substation monitoring systems

Manufacturer

Cambridge Sensotec

RX1100-ZRapidox 1100

Versatile O₂ analyser with zirconia, electrochemical or optical sensor for ppm and percent measurements

Key specifications

O₂ range
0.5 ppm – 30% (zirconia); 0.1 ppm – 100% (electrochemical/optical)
Accuracy
±1% of reading
Outputs
0–10 V, 4–20 mA, RS232/Modbus
Pump
0–1.2 l/min (optional)
Power supply
90–260 V AC