Reheating furnace monitoring
Metallurgy reheating furnaces: fans, burners, exhausters, drives — SDT, Bently, Artesis. Gas leak and bearing control. KEG TRK.

Reheating furnaces
Focus on fans/exhausters, charging drives and fuel-gas leaks — the rotating and utility systems that stop both furnace and rolling mill.
Olympus — NDT and remote visual inspection
- Thickness gauging — casings, piping and vessels (39DL PLUS)
- Videoscopes — cavities and flow paths on outages (IPLEX One)
Catalogs: NDT · endoscopes · Olympus brand.
SDT for reheating furnace monitoring monitoring
SDT Ultrasound instruments deliver full acoustic condition monitoring in dusty, noisy plants
Artesis — continuous drive monitoring
Artesis EMCM analyzes motor current and voltage without sensors on the machine
Bently Nevada — vibration diagnostics
Permanent and distributed systems for critical mining assets

200150 Series — IEPE accelerometer
IEPE piezoelectric accelerometers for industrial vibration and bearing health measurement

SCOUT Series — portable vibration analyzers
Portable data collectors and analyzers for equipment diagnostics

2300 Series — hydro turbine monitoring
Specialized monitoring for hydro turbines and hydrogenerators
Olympus — thickness gauging and videoscopes
When vibration finds a symptom, Olympus confirms metal, weld or internal cavity condition

Olympus 39DL PLUS — ultrasonic thickness gauge
General-purpose Olympus (Evident) ultrasonic thickness gauge, successor to the 38DL PLUS: 0.08–635 mm, up to 60 Hz update, single and dual element transducers, THRU-COAT, Echo-to-Echo, B-scan, up to 792,832 readings, IP67, 0.83 kg.

Olympus IPLEX One — 10th-generation videoscope
The 10th generation of Olympus (Evident) IPLEX videoscopes: Plus, Expert and Prime tiers on one hardware platform, Swoptix optics without withdrawing the probe, 3DAssist, 10.1" 1100-nit tablet, four light sources, up to 360 min runtime.

Olympus IPLEX NX — flagship industrial videoscope
Flagship Olympus (Evident) videoscope: laser illumination up to 4 times brighter, stereo measurement and 3D defect modelling, 8.4" touchscreen, Ø4.0–6.2 mm probes up to 7.5 m, articulation up to 180°.
Ion Science — SF6, VOC and industrial leaks
Portable and fixed detectors for SF6 at substations, VOC on chemical sites and refrigerant leaks in HVAC

Ion Science Tiger XT — handheld PID detector for volatile organic compounds
Intrinsically safe Ion Science photoionisation detector for over 750 volatile organic compounds: 1 ppb to 20,000 ppm, T90 under 2 s, Fence Electrode technology against humidity and contamination, up to 24 h runtime and 120,000 logged readings.

Ion Science Falco 2 — fixed PID VOC detector
Flameproof fixed photoionisation detector for over 700 volatile organic compounds: diffused or pumped, ranges from 0–10 to 0–3000 ppm, a TAC version for benzene, 4–20 mA, RS485 Modbus and two relays.
Solutions and resources
Products, related applications and articles for Reheating furnace monitoring
Recommended products
Related applications
Useful articles
- Vibration Monitoring of Rolling Mill Auxiliary Drives — Bently Nevada
- Fan and Induced Draft Fan Monitoring in Metallurgical Shops — Bently Nevada
- 3300 XL Eddy Current Probes on Large Fans — Bently Nevada
- Predictive Maintenance of Metallurgy Gearboxes: Spectral Analysis — Bently Nevada
FAQ: Reheating furnace monitoring monitoring
Need advice?
Our specialists will help you choose the optimal Reheating furnace monitoring configuration for your equipment.