Supply in Kazakhstan
KEG TRK supplies measurement instrumentation solutions (ELEMER) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.
Key features
Applications and resources
Industry solutions, landing pages and articles about Reference Pressure Transmitter PDE-040
Where it is used
Typical tasks
- Verification and calibration of pressure sensors
- Metrology laboratories
- Oxygen equipment (O2 version)
Description
PDE-040 is a reference pressure transmitter by ELEMER, a multi-range (reconfigurable) working standard with accuracy from ±0.015%, used for verifying and calibrating pressure sensors in metrology laboratories.
It covers three pressure types - absolute (10 kPa-16 MPa), gauge (1 kPa-100 MPa) and gauge/vacuum (-100 kPa-2.5 MPa). Mean time between failures is at least 100,000 hours, service life at least 12 years. The calibration interval depends on accuracy class, from 1 year (for the most precise modifications) to 3 years. Explosion-proof versions and a special O2 version for oxygen equipment (with degreasing) are available.
Technical specifications
| Device type | PDE-040 |
| Absolute pressure (AP) | 10 kPa - 16 MPa |
| Gauge pressure (GP) | 1 kPa - 100 MPa |
| Gauge/vacuum (GV) | -100 kPa - 2.5 MPa |
| Accuracy (gamma) | ±0.015% / ±0.025% / ±0.05% / ±0.1% |
| Climatic version | -20...+60 °C |
| Protection rating | IP65 / IP65/IP67 |
| Mean time between failures | at least 100,000 hours |
| Service life | at least 12 years |
| Calibration interval | 1 year (gamma=0.015-0.025%) / 2 years (gamma=0.05%) / 3 years (gamma=0.1%) |
| Versions | general industrial, Ex (0Ex ia IIC T6...T4 Ga X), Ex (1Ex ia IIB T6...T4 Gb X), O2 (oxygen) |
Applications
Certificates and approvals
- ✓ELEMER technical documentation
Manufacturer
ELEMER
Reference pressure transmitter PDE-040 - working standard, accuracy from ±0.015%
Key specifications
- Device type
- PDE-040
- Absolute pressure (AP)
- 10 kPa - 16 MPa
- Gauge pressure (GP)
- 1 kPa - 100 MPa
- Gauge/vacuum (GV)
- -100 kPa - 2.5 MPa
- Accuracy (gamma)
- ±0.015% / ±0.025% / ±0.05% / ±0.1%
Official supplier in Kazakhstan
Related products
Reference Digital Manometers MCE
Reference digital manometer ELEMER-MCE-040 - working standard for pressure sensor verification and c...
ELEMER
Pressure Calibrators AKD, PKD, KDM
Pressure calibrators ELEMER-AKD, PKD, KDM - working standards for pressure sensor verification
ELEMER
Verification System ELEMER-PU
Verification system ELEMER-PU for calibrating and verifying flow meters, DN 1-600 mm
ELEMER
Need advice?