Supply in Kazakhstan
KEG TRK supplies measurement instrumentation solutions (ELEMER) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.
Key features
Applications and resources
Industry solutions, landing pages and articles about Verification System ELEMER-PU
Where it is used
Typical tasks
- Calibration and verification of flow meters and flow counters
- Working and secondary standards per the verification scheme
- Metrology laboratories and verification centers
Description
ELEMER-PU is a verification system by ELEMER for calibrating, configuring, verifying and testing flow meters and flow counters of various types. Used as a working and secondary standard in accordance with the state verification scheme.
The system covers a flow range from 0.001 to 4000 t/h (m3/h) depending on the measurement method (weighing, mass or volumetric flow meters), with four accuracy classes - from ±0.040% (class 1) to ±1.00% (class 4). Allows simultaneous verification of 1 to 32 instruments with nominal diameters from DN 1 to DN 600 mm. Measured media are drinking water and water-glycol mixtures, operating pressure up to 2.5 MPa.
Technical specifications
| Range (weighing method) | 0.001-2000 t/h (m3/h) |
| Range (mass flow meters) | 0.001-4000 t/h (m3/h) |
| Range (volumetric flow meters) | 0.001-4000 m3/h |
| System accuracy classes | 1, 2, 3, 4 |
| Accuracy (class 1) | ±0.040...±0.055% |
| Accuracy (class 4) | ±0.30...±1.00% |
| Nominal diameter | DN 1-600 mm |
| Instruments verified simultaneously | 1-32 |
| Measured media | drinking water, water-glycol mixtures |
| Operating pressure | 0.1-2.5 MPa |
| Power supply | 380±38 V or 220±22 V, 50±1 Hz |
Applications
Certificates and approvals
- ✓Type approval certificate No. 85095-22 (valid until 04.04.2027)
Manufacturer
ELEMER
Verification system ELEMER-PU for calibrating and verifying flow meters, DN 1-600 mm
Key specifications
- Range (weighing method)
- 0.001-2000 t/h (m3/h)
- Range (mass flow meters)
- 0.001-4000 t/h (m3/h)
- Range (volumetric flow meters)
- 0.001-4000 m3/h
- System accuracy classes
- 1, 2, 3, 4
- Accuracy (class 1)
- ±0.040...±0.055%
Official supplier in Kazakhstan
Related products
Electromagnetic Flow Meters
ELEMER-REM electromagnetic flow meters for conductive liquids, DN 15-400 mm
ELEMER
Vortex Flow Meters
ELEMER-RV vortex flow meters for gas, steam and liquids, DN 25-300 mm, pressure up to 25 MPa
ELEMER
Universal Flow Computer ELEMER-VKM-360
Flow computer ELEMER-VKM-360A/B - up to 10 pipelines, supports water, steam, gas, oil
ELEMER
Need advice?
Our specialists will help you choose the optimal Verification System ELEMER-PU configuration for your equipment.