Bently Nevada3500 Series3500/60

3500/60 Temperature Monitor

3500/60 Temperature Monitor: 6 RTD or thermocouple channels for bearings and process points

3500/60 Temperature Monitor — Bently Nevada
3500/60 Temperature Monitor

Supply in Kazakhstan

KEG TRK supplies vibration monitoring and analysis solutions (Bently Nevada) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.

Key features

6 RTD or thermocouple channels
100 Ω Pt, 120 Ω Ni, 10 Ω Cu; E, J, K, T thermocouples
Temperature and differential temperature
Isolated thermocouple version (250 Vdc)

Industry solutions, landing pages and articles about 3500/60 Temperature Monitor

Documentation

Official Baker Hughes / Bently Nevada manufacturer PDFs. Key specifications are also published on this page for search and equipment selection.

Need a price with delivery in Kazakhstan? We will prepare a quotation for your task.

Description

The 3500/60 is a six-channel temperature monitor for the 3500 rack. It takes RTDs and thermocouples, measures temperature or differential temperature and compares them with setpoints. The non-isolated I/O takes RTD, TC or a mix; the isolated I/O takes thermocouples only, with 250 Vdc channel-to-channel isolation.

Specifications (datasheet 141540)

Parameter Value
Channels 6 channels
Inputs RTDs (100 Ω Pt, 120 Ω Ni, 10 Ω Cu; 3- and 4-wire) and E, J, K, T thermocouples
Outputs no 4–20 mA (use the 3500/61 if needed); relays via 3500/32M/33
Isolation TC isolated version: 250 Vdc channel-to-channel

Supply in Kazakhstan

KEG TRK supplies the 3500/60 and its I/O modules and helps with 3500 rack configuration and commissioning across Kazakhstan.

Manufacturer

Bently Nevada

3500/603500 Series

3500/60 Temperature Monitor: 6 RTD or thermocouple channels for bearings and process points

Key specifications

Channels
6 channels
Inputs
RTDs (100 Ω Pt, 120 Ω Ni, 10 Ω Cu; 3- and 4-wire) and E, J, K, T thermocouples
Outputs
no 4–20 mA (use the 3500/61 if needed); relays via 3500/32M/33
Isolation
TC isolated version: 250 Vdc channel-to-channel
Bently Nevada part number
3500/60

Official supplier in Kazakhstan

Need advice?

Our specialists will help you choose the optimal 3500/60 Temperature Monitor configuration for your equipment.

Related articles

All articles →
10 Equipment Maintenance Strategies That Cut Downtime in 2026
Article

10 Equipment Maintenance Strategies That Cut Downtime in 2026

10 maintenance strategies that genuinely reduce downtime in 2026: predictive maintenance, RCM, TPM, and tools like Artesis e-MCM and SDT340, with KPIs you can roll out in stages at plants across Kazakhstan.

Shaft Misalignment: the Hidden Killer of Bearings, Couplings and Seals
Article

Shaft Misalignment: the Hidden Killer of Bearings, Couplings and Seals

Up to half of all rotating equipment failures are linked to shaft misalignment. We break down the types of misalignment, its consequences, and how vibration analysis and current analysis detect it before it destroys couplings and bearings.

What an Hour of Downtime Really Costs and How to Cut Unplanned Stops
Article

What an Hour of Downtime Really Costs and How to Cut Unplanned Stops

Unplanned downtime costs far more than the repair crew's payroll line suggests. We break down the full cost-of-downtime formula and show how switching to predictive maintenance cuts unplanned stops by 30–50%.

4 Stages of Bearing Failure: How to Catch a Defect Months Before It Fails
Article

4 Stages of Bearing Failure: How to Catch a Defect Months Before It Fails

A bearing doesn't fail instantly — it goes through 4 stages of degradation, and the first one is only visible to ultrasound. We break down the P-F curve and which diagnostic method works at each stage of bearing failure.

The Mysterious 0.6× Frequency — a Frequency That Shouldn't Exist (But Does)
Article

The Mysterious 0.6× Frequency — a Frequency That Shouldn't Exist (But Does)

A peak at 0.6× in the spectrum isn't always BPFO. A thought experiment on changing reference frames, and how to confirm the hypothesis with SDT340 ultrasound and Artesis electrical signatures.

Gearbox Diagnostics: Tooth Wear, Pitting and Misalignment Before Shutdown
Article

Gearbox Diagnostics: Tooth Wear, Pitting and Misalignment Before Shutdown

How to catch gear tooth wear, pitting and misalignment before an emergency stop. SDT 340 ultrasound walkdowns plus Artesis e-MCM on the drive motor — field experience from mining and metallurgy in Kazakhstan.