Cambridge SensotecSF6 Analyzers

Rapidox 6100 C4-FN & C5-FK Multi-Gas Pumpback — Analyser for SF6-Alternative Gas Mixtures

Portable automatic pump-back analyser for C4-FN (g3, Novec 4710) and C5-FK (AirPlus, Novec 5110) mixtures with CO₂ and O₂. Purity, moisture and CO in 2–8 minutes with no gas released to atmosphere.

Rapidox 6100 C4-FN & C5-FK Multi-Gas Pumpback — Analyser for SF6-Alternative Gas Mixtures — Cambridge Sensotec
Rapidox 6100 C4-FN & C5-FK Multi-Gas Pumpback — Analyser for SF6-Alternative Gas Mixtures

Supply in Kazakhstan

KEG TRK supplies SF6 gas analysis solutions (Cambridge Sensotec) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.

Key features

C4-FN + CO₂/O₂ (g3) and C5-FK + CO₂ (AirPlus) mixtures
Up to 6 gases measured simultaneously for each mixture type
Sample returned to the equipment by a compressor at up to 10 bar
Vacuum purge keeps air out of the sample
7-inch colour touch screen, built-in thermal printer
4 GB memory, Excel export via USB stick
Lithium battery up to 8 hours, IP66 Peli case with wheels

Industry solutions, landing pages and articles about Rapidox 6100 C4-FN & C5-FK Multi-Gas Pumpback — Analyser for SF6-Alternative Gas Mixtures

Typical tasks

  • GIS and circuit breakers insulated with g3 (C4-FN)
  • Equipment insulated with AirPlus (C5-FK)
  • Gas-insulated transformers
  • Incoming inspection of gas cylinders
  • Commissioning and periodic testing

Fully automatic pump-back analyzer for eco-friendly C4-FN and C5-FK gas mixtures used in next-generation switchgear.

Overview

The Rapidox 6100 C4-FN & C5-FK Multi-Gas Pumpback is a portable analyser from the British company Cambridge Sensotec for SF6-free gas-insulated equipment. It tests mixtures based on C4-FN (g3, Novec 4710) and C5-FK (AirPlus, Novec 5110), which switchgear and circuit breaker manufacturers use to replace SF6.

In one cycle the instrument measures mixture purity, carrier gas content, moisture and CO. After the measurement the sample is returned to the equipment, so no gas is lost or released to atmosphere.

Why C4-FN and C5-FK need to be monitored

Alternative gases are not used pure but in mixtures. C4-FN is usually blended with CO₂ and O₂, C5-FK with CO₂ and air. Insulating performance depends on the exact ratio, so the mixture must be checked after filling, topping up and repair.

What regular analysis gives you:

  • Mixture composition. A drop in C4-FN or C5-FK content lowers the dielectric strength of the insulation.
  • Moisture. Water in the compartment degrades insulation and speeds up gas decomposition.
  • CO. Carbon monoxide is the main decomposition product from arcing and partial discharge. A rise signals a problem inside the apparatus.
  • Personnel safety. Decomposition products are toxic, so their level is checked before a compartment is opened.

According to Cambridge Sensotec, these gases have a much lower global warming potential than SF6 but remain harmful to the atmosphere. Their release during testing is therefore controlled as strictly as for SF6.

How a measurement works

  1. The operator connects the instrument to the compartment or cylinder through a Rectus-style fitting (DN8 and DN20 adaptors supplied) and selects the mixture type on screen.
  2. If the instrument was previously used with another gas, it runs a purge and sends the remainder to an external recovery bag.
  3. The Rapidox draws a small amount of pressurised gas. A vacuum purge and internal storage keep air out of the sample.
  4. All gases are measured simultaneously; a stable reading takes a few minutes.
  5. The compressor returns the gas to the equipment at up to 10 bar. Results are shown on screen, logged and printed if required.

Built-in safety features make sure the cycle completes without gas loss or cross-contamination.

Sensors and ranges

Parameter Range Accuracy Sensor type Calibration Life span
C4-FN / C5-FK 0–20 % ±0.5 % IR 12–24 months over 5 years
CO₂ 0–100 % ±0.5 % IR 12–24 months over 5 years
Air / O₂ / N₂ 0–100 % air, 0–30 % O₂ ±1 % FS electrochemical 12–24 months up to 5 years
H₂O (dew point) -60 to +20 °Cdp (10–24,000 ppmV) ±2 °Cdp polymer 12 months (sensor exchange) 2–3 years
CO 0–500, 0–1,000, 0–2,000, 0–5,000 ppm ±2 % FS electrochemical 12–24 months up to 5 years

Moisture is shown as dew point or ppmV, corrected to the actual temperature or to 20 °C. One configuration can analyse up to six gases per mixture type. The sensor set is chosen at ordering and can be extended later.

Technical specifications

Parameter Value
Measurement time 2–8 min (min. 6 min for H₂O)
Warm-up 3–4 min at 20 °C, 15 min for full accuracy
Inlet pressure 0.5–35 bar (up to 10 bar in pump-back mode)
Sample flow 0.5 L/min
Pump-back compressor up to 10 bar, up to 25 cycles per charge at 20 °C
Display 7" (178 mm) colour LCD touch screen
Printer built-in thermal printer
Memory 4 GB, about one year of continuous logging
Data export Excel-compatible files to a USB stick
Sample connection Rectus-style fitting, DN8 and DN20 adaptors
Power lithium battery up to 8 h, 4–6 h charge, mains 90–260 V
Operating conditions -10 to +40 °C, 10–90 % RH, 600–1100 mbar
Housing IP66 Peli case with trolley and handles
Dimensions 270 × 560 × 450 mm (H × W × D)
Weight 21 kg with case

Rapidox 6100 models compared

Model Gases Best for
Rapidox SF6 6100 Pump Back SF6 SF6-only fleets
Rapidox 6100 Clean Air technical air (N₂/O₂) Clean Air insulated equipment
Rapidox 6100 C4-FN & C5-FK C4-FN and C5-FK mixtures g3 and AirPlus equipment
Rapidox 6100 QU4D SF6, C4-FN, C5-FK, Clean Air Mixed fleets, one instrument for all gases

What is included

  • Rapidox 6100 C4-FN & C5-FK analyser in a Peli case with trolley;
  • sample hoses;
  • DN8 and DN20 adaptors;
  • charger;
  • user manual.

Optional: gas recovery bag, hose and adaptor kit, calibration gas mixtures.

Supply in Kazakhstan

KEG TRK supplies Cambridge Sensotec analysers to power utilities and contractors who service gas-insulated switchgear. We help choose the sensor configuration for your equipment fleet and select adaptors for your apparatus. Price on request.

Manufacturer

Cambridge Sensotec

SF6 Analyzers

Portable automatic pump-back analyser for C4-FN (g3, Novec 4710) and C5-FK (AirPlus, Novec 5110) mixtures with CO₂ and O₂. Purity, moisture and CO in 2–8 minutes with no gas released to atmosphere.

Key specifications

Display
7" (178 mm) colour LCD touch screen
C4-FN (Novec 4710)
0–20 %, ±0.5 % (IR sensor)
C5-FK (Novec 5110)
0–20 %, ±0.5 % (IR sensor)
CO₂ (carbon dioxide)
0–100 %, ±0.5 % (IR sensor)
O₂ / air
0–30 % O₂ / 0–100 % air, ±1 % FS (electrochemical)

Official supplier in Kazakhstan

Related products

Rapidox 6100 QU4D Multi-Gas Pumpback — SF6, C4-FN, C5-FK and Clean Air Analyser
Cambridge Sensotec

Rapidox 6100 QU4D Multi-Gas Pumpback — SF6, C4-FN, C5-FK and Clean Air Analyser

One portable pump-back analyser for four insulation types: SF6, C4-FN, C5-FK and Clean Air. Purity, moisture and decomposition products in 2–8 minutes, with IEC and CIGRE test configurations built in.

  • SF6 + CF4; C4-FN + CO₂/O₂; C5-FK + CO₂; Clean Air (N₂ + O₂)
  • SF6 0–100 %, ±0.5 % (IR or density)
Price on requestLearn more
Rapidox 6100 Clean Air Pumpback — Clean Air Insulation Gas Analyser
Cambridge Sensotec

Rapidox 6100 Clean Air Pumpback — Clean Air Insulation Gas Analyser

Portable pump-back analyser for Clean Air insulated equipment (N₂ and O₂ blend): composition, moisture and NO₂ in 2–8 minutes without the sample touching ambient air.

  • 0–30 % O₂ / 0–100 % air, ±1 % FS (electrochemical)
  • -60 to +20 °Cdp (10–24,000 ppmV), ±2 °Cdp
Price on requestLearn more
Rapidox SF6 6100 MK2 Pump Back — SF6 Analyser with Gas Return
Cambridge Sensotec

Rapidox SF6 6100 MK2 Pump Back — SF6 Analyser with Gas Return

Fully automatic zero-emissions SF6 analyser: purity, moisture and decomposition products in 2–8 minutes, then a compressor returns the gas to the equipment at up to 10 bar. Three calibrations for cold, warm and hot climates.

  • SF6 0–100 %, ±0.5 % (IR or density)
  • -60 to +20 °Cdp (10–24,000 ppmV), ±2 °Cdp
Price on requestLearn more
Rapidox SF6 Gas Recovery Bag — Bag for Collecting SF6 After Analysis
Cambridge Sensotec

Rapidox SF6 Gas Recovery Bag — Bag for Collecting SF6 After Analysis

80-litre bag for collecting SF6 after analysis: self-sealing couplings, 0.2 bar safety relief valve, heavy-duty PU-coated polyamide. Compatible with the Rapidox SF6 6100 Portable and Bench.

  • up to 80 L
  • max 0.24 bar; relief valve 0.2 bar; vacuum to -50 mbar
Price on requestLearn more
SF6 Hose Connection Kit - Insulating Gas Hose Connection Set
Cambridge Sensotec

SF6 Hose Connection Kit - Insulating Gas Hose Connection Set

Universal RECTUS 21 adapter kit for connecting SF6 gas analyzers to Siemens, ABB, Hitachi, Schneider, GE and Mitsubishi equipment, in an impact-resistant IP65 case

  • SF6 auxiliary equipment
  • RECTUS 21 (Series 21) — industry standard
Price on requestLearn more

Need advice?

Our specialists will help you choose the optimal Rapidox 6100 C4-FN & C5-FK Multi-Gas Pumpback — Analyser for SF6-Alternative Gas Mixtures configuration for your equipment.

Related articles

All articles →

Часто задаваемые вопросы