Supply in Kazakhstan
KEG TRK supplies SF6 gas analysis solutions (Cambridge Sensotec) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.
Key features
Applications and resources
Industry solutions, landing pages and articles about Rapidox 6100 Clean Air Pumpback — Clean Air Insulation Gas Analyser
Where it is used
Typical tasks
- Switchgear and breakers insulated with Clean Air (Dry Air)
- Medium-voltage distribution networks
- Commissioning of new SF6-free equipment
- Periodic moisture checks
- Incoming cylinder inspection
Rapidox 6100 Clean Air Pumpback measures SF6 and clean-air mixtures with minimal gas loss during sampling.
Overview
The Rapidox 6100 Clean Air Pumpback is a portable analyser from the British company Cambridge Sensotec for equipment insulated with Clean Air. Clean Air, also called Dry Air, is a purified and dried blend of nitrogen and oxygen that manufacturers use to replace SF6 in low, medium and high voltage apparatus.
The instrument measures mixture composition, moisture and NO₂, then returns the sample to the equipment. It does not measure SF6.
Why Clean Air must be monitored
According to Cambridge Sensotec, Clean Air has zero global warming potential versus 23,900 for SF6. But its insulating performance depends heavily on moisture. If the sample mixes with ambient air, it loses its dryness and the measurement becomes meaningless.
Regular analysis shows:
- mixture composition — the O₂/N₂ ratio after filling and topping up;
- moisture — the key parameter for Clean Air;
- NO₂ — a sign of discharge or arcing inside the apparatus.
How a measurement works
- Connect to the compartment or cylinder through a Rectus-style fitting; DN8 and DN20 adaptors are supplied.
- The instrument draws a small amount of pressurised gas. A vacuum purge and internal storage keep ambient air out.
- Readings stabilise within a few minutes; moisture needs at least 6 minutes.
- The compressor returns the gas at up to 10 bar. Results are logged and printed on demand.
Sensors and ranges
| Parameter | Range | Accuracy | Sensor type | Calibration | Life span |
|---|---|---|---|---|---|
| Air / O₂ / N₂ | 0–100 % air, 0–30 % O₂ | ±1 % FS | electrochemical | 12–24 months | up to 5 years |
| H₂O (dew point) | -60 to +20 °Cdp (10–24,000 ppmV) | ±2 °Cdp | polymer | 12 months (sensor exchange) | 2–3 years |
| NO₂ | 0–20 or 0–200 ppm | ±2 % FS | electrochemical | 12–24 months | up to 4 years |
Technical specifications
| Parameter | Value |
|---|---|
| Measurement time | 2–8 min (min. 6 min for H₂O) |
| Warm-up | 3–4 min at 20 °C, 15 min for full accuracy |
| Inlet pressure | 0.5–35 bar (up to 10 bar in pump-back mode) |
| Sample flow | 0.5 L/min |
| Pump-back compressor | up to 10 bar, up to 15 cycles per charge at 20 °C |
| Display | 7" (178 mm) colour LCD touch screen |
| Printer | built-in thermal printer |
| Memory | 4 GB, about one year of continuous logging |
| Data export | Excel-compatible files to a USB stick |
| Power | lithium battery up to 8 h, 4–6 h charge, mains 90–260 V |
| Operating conditions | -10 to +40 °C, 10–90 % RH, 600–1100 mbar |
| Housing | IP66 Peli case with trolley and handles |
| Dimensions | 270 × 560 × 450 mm (H × W × D) |
| Weight | 21 kg with case |
Other Rapidox 6100 models
- Rapidox 6100 QU4D — SF6, C4-FN, C5-FK and Clean Air in one instrument.
- Rapidox 6100 C4-FN & C5-FK — g3 and AirPlus mixtures.
- Rapidox SF6 6100 Pump Back — SF6.
Supply in Kazakhstan
KEG TRK supplies Cambridge Sensotec analysers to power utilities and contractors. We help choose the model for your equipment fleet and select adaptors. Price on request.
Technical specifications
| O₂ / air | 0–30 % O₂ / 0–100 % air, ±1 % FS (electrochemical) |
| Moisture (dew point) | -60 to +20 °Cdp (10–24,000 ppmV), ±2 °Cdp |
| Decomposition products | NO₂ 0–20 or 0–200 ppm, ±2 % FS |
| Measurement time | 2–8 min (min. 6 min for H₂O) |
| Pump | pump-back compressor up to 10 bar, up to 15 cycles per charge |
| Pressure | 0.5–35 bar inlet (up to 10 bar in pump-back mode) |
| Display | 7" (178 mm) colour LCD touch screen |
| Battery | lithium, up to 8 hours, 4–6 h charge |
| Protection | IP66 Peli case with trolley |
| Weight | 21 kg (instrument with case) |
| Dimensions | 270 × 560 × 450 mm (H × W × D) |
Applications
Manufacturer
Cambridge Sensotec
Portable pump-back analyser for Clean Air insulated equipment (N₂ and O₂ blend): composition, moisture and NO₂ in 2–8 minutes without the sample touching ambient air.
Key specifications
- O₂ / air
- 0–30 % O₂ / 0–100 % air, ±1 % FS (electrochemical)
- Moisture (dew point)
- -60 to +20 °Cdp (10–24,000 ppmV), ±2 °Cdp
- Decomposition products
- NO₂ 0–20 or 0–200 ppm, ±2 % FS
- Measurement time
- 2–8 min (min. 6 min for H₂O)
- Pump
- pump-back compressor up to 10 bar, up to 15 cycles per charge
Official supplier in Kazakhstan
Related products

Rapidox 6100 QU4D Multi-Gas Pumpback — SF6, C4-FN, C5-FK and Clean Air Analyser
One portable pump-back analyser for four insulation types: SF6, C4-FN, C5-FK and Clean Air. Purity, moisture and decomposition products in 2–8 minutes, with IEC and CIGRE test configurations built in.
- SF6 + CF4; C4-FN + CO₂/O₂; C5-FK + CO₂; Clean Air (N₂ + O₂)
- SF6 0–100 %, ±0.5 % (IR or density)

Rapidox 6100 C4-FN & C5-FK Multi-Gas Pumpback — Analyser for SF6-Alternative Gas Mixtures
Portable automatic pump-back analyser for C4-FN (g3, Novec 4710) and C5-FK (AirPlus, Novec 5110) mixtures with CO₂ and O₂. Purity, moisture and CO in 2–8 minutes with no gas released to atmosphere.
- 7" (178 mm) colour LCD touch screen
- 0–20 %, ±0.5 % (IR sensor)

Rapidox SF6 6100 MK2 Pump Back — SF6 Analyser with Gas Return
Fully automatic zero-emissions SF6 analyser: purity, moisture and decomposition products in 2–8 minutes, then a compressor returns the gas to the equipment at up to 10 bar. Three calibrations for cold, warm and hot climates.
- SF6 0–100 %, ±0.5 % (IR or density)
- -60 to +20 °Cdp (10–24,000 ppmV), ±2 °Cdp

Rapidox SF6 Gas Recovery Bag — Bag for Collecting SF6 After Analysis
80-litre bag for collecting SF6 after analysis: self-sealing couplings, 0.2 bar safety relief valve, heavy-duty PU-coated polyamide. Compatible with the Rapidox SF6 6100 Portable and Bench.
- up to 80 L
- max 0.24 bar; relief valve 0.2 bar; vacuum to -50 mbar

SF6 Hose Connection Kit - Insulating Gas Hose Connection Set
Universal RECTUS 21 adapter kit for connecting SF6 gas analyzers to Siemens, ABB, Hitachi, Schneider, GE and Mitsubishi equipment, in an impact-resistant IP65 case
- SF6 auxiliary equipment
- RECTUS 21 (Series 21) — industry standard
Need advice?
Our specialists will help you choose the optimal Rapidox 6100 Clean Air Pumpback — Clean Air Insulation Gas Analyser configuration for your equipment.
Related articles
All articles →
Integrated Monitoring of CHP Transformer Bays: Rapidox, Vibration and Ultrasound
A CHP transformer bay is transformer, breakers, cooling and switchgear in one reliability loop. How to unify Rapidox (SF₆, O₂, Clean Air), Bently on oil pumps and SDT for partial discharges in one procedure.
Clean Air and Oxygen in SF₆-Free Switchgear: Monitoring at CHP During the SF₆ Transition
New dry-air (Clean Air) switchgear at CHP plants needs O₂, humidity and purity control. Rapidox 6100 Clean Air Pumpback for mixed SF₆ and SF₆-free fleets.

Oxygen Depletion in Enclosed MV Switchgear: O₂ and SF₆ Monitoring at CHP Substations
SF₆ leaks in enclosed switchgear displace oxygen below safe levels with no smell or visible warning. How to combine SF₆ and O₂ monitoring with Rapidox at combined heat and power substations.

Vibration Monitoring of Power Transformer Cooling Auxiliaries at CHP Plants
Oil pumps, radiator fans and water-cooling pumps on step-up transformers are a hidden CHP outage source. Bently Nevada 3500/42M, Orbit DCM and 1900/65A for transformer yard auxiliaries.

Transformer DGA at CHP: What to Add Beyond Oil Chromatography
Dissolved gas analysis (DGA) is the gold standard for transformer diagnosis but not the only tool. Companion methods at CHP plants: cooling vibration, PD ultrasound, SF₆ and O₂ on adjacent switchgear.