Ion ScienceTigerTiger XT Select

Ion Science Tiger XT Select — handheld benzene detector

Intrinsically safe Ion Science PID detector for selective benzene measurement from 0.01 ppm with pre-filter tubes, total aromatic compounds (TAC) with STEL and TWA, and total VOC from 1 ppb in standard mode.

Ion Science Tiger XT Select — handheld benzene detector — Ion Science
Ion Science Tiger XT Select — handheld benzene detector

Supply in Kazakhstan

KEG TRK supplies equipment diagnostics solutions (Ion Science) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.

Key features

Selective benzene measurement 0.01–200 ppm with a pre-filter tube
TAC mode — total aromatic compounds, 15-min STEL and 8-h TWA
Standard VOC mode from 1 ppb to 20,000 ppm
10.0 eV lamp, Fence Electrode Technology
Real-time indication of benzene breakthrough in the tube
ATEX/IECEx II 1G Ex ia IIC T4 Ga, Class I Div. 1
IP65, 95 dBA sounder, vibration, built-in torch
Up to 24 h on Li-ion, 120,000 data points

Industry solutions, landing pages and articles on Ion Science Tiger XT Select — handheld benzene detector

Typical tasks

  • Benzene monitoring at refineries, petrochemical plants and terminals
  • Maintenance of petroleum product tanks
  • Personal benzene exposure assessment (STEL / TWA)
  • Rounds of reformers, aromatics units and loading racks
  • Entry into tanks that held gasoline or aromatics

Overview

The Tiger XT Select is a handheld photoionisation detector from the British company Ion Science for measuring benzene. Benzene is a carcinogen with very low exposure limits, and at refineries and chemical plants it is almost always mixed with other hydrocarbons. A standard PID shows their sum; the Tiger XT Select can isolate benzene.

Ion Science Tiger XT Select

Three operating modes

Mode Measures Range Time
Pre-filter tube benzene only 0.01–200 ppm, 0.001 ppm resolution about 130 s
TAC total aromatics, STEL and TWA from 0.01 ppm under 2 s
Standard all VOCs as benzene equivalent 1 ppb to 20,000 ppm under 2 s

Operators usually survey in TAC or standard mode and fit a tube when readings rise to find out how much of the mixture is benzene.

Features

  • 10.0 eV lamp chosen for aromatic hydrocarbons.
  • Fence Electrode protects the sensor against moisture and contamination.
  • Breakthrough progress of benzene through the tube shown on screen in real time.
  • Alarms: amber and red LEDs, 95 dBA sounder at 300 mm, vibration.
  • Built-in torch for dark rooms and tanks.
  • Semi-conductive elastomer housing for intrinsic safety.

Technical specifications

Parameter Value
Principle PID, 10.0 eV lamp, Fence Electrode
Benzene (tube) 0.01–200 ppm (up to 639 mg/m³)
Resolution 0.001 ppm
Tube life typically about 100 h
Flow at least 220 ml/min, blockage detection
Data logging 120,000 points
Power Li-ion up to 24 h or 3 × AA about 8.5 h
Certification ATEX/IECEx II 1G Ex ia IIC T4 Ga; Class I Div. 1
Protection IP65
Operating temperature −25 to +45 °C (Li-ion)
Dimensions 370 × 91 × 60 mm
Weight 870 g

Portable or fixed benzene monitoring

The Tiger XT Select is for rounds and spot measurements. For continuous monitoring at one point, such as a pump house or loading rack, use the fixed Titan 2; for personal monitoring, the wearable Cub. For all VOCs without benzene selectivity, use the Tiger XT.

Supply in Kazakhstan

KEG TRK is the official representative of Ion Science in Kazakhstan. We supply detectors and pre-filter tubes and arrange calibration and training. Price on request.

Manufacturer

Ion Science

Tiger XT SelectTiger

Intrinsically safe Ion Science PID detector for selective benzene measurement from 0.01 ppm with pre-filter tubes, total aromatic compounds (TAC) with STEL and TWA, and total VOC from 1 ppb in standard mode.

Key specifications

Technology
PID, 10.0 eV lamp, Fence Electrode
Benzene (tube mode)
0.01–200 ppm (up to 639 mg/m³), 0.001 ppm resolution
Total aromatics (TAC)
from 0.01 ppm, STEL and TWA
Standard VOC mode
from 1 ppb (ppb model) to 20,000 ppm
Response time
under 2 s; about 130 s in tube mode at 20 °C

Official supplier in Kazakhstan

Related products

Ion Science Tiger XT — handheld PID detector for volatile organic compounds
Ion ScienceTiger XT

Ion Science Tiger XT — handheld PID detector for volatile organic compounds

Intrinsically safe Ion Science photoionisation detector for over 750 volatile organic compounds: 1 ppb to 20,000 ppm, T90 under 2 s, Fence Electrode technology against humidity and contamination, up to 24 h runtime and 120,000 logged readings.

  • photoionisation detector (PID), Fence Electrode
  • over 750 VOCs and toxic compounds
Price on requestLearn more
Ion Science Titan 2 — fixed benzene monitor
Ion ScienceTitan 2

Ion Science Titan 2 — fixed benzene monitor

Flameproof fixed benzene monitor: MiniPID sensor with a proprietary separation method, 20 ppb – 20 ppm range, one reading per minute, 4–20 mA, RS485 Modbus and two relays. Ex db IIB+H2 T4 Gb, IP65.

  • fixed benzene monitor
  • MiniPID T2, 10.0 eV, proprietary separation method
Price on requestLearn more
Ion Science Tiger XTL — handheld PID VOC detector for routine rounds
Ion ScienceTiger XTL

Ion Science Tiger XTL — handheld PID VOC detector for routine rounds

Simplified version of the Tiger photoionisation detector: 0.1–5,000 ppm range, T90 under 2 s, 80,000 data points in 128 zones, ATEX and IECEx certified, IP65, up to 24 h runtime.

  • photoionisation detector (PID), Fence Electrode
  • 10.6 eV (krypton)
Price on requestLearn more
Ion Science Cub — personal VOC monitor
Ion ScienceCub

Ion Science Cub — personal VOC monitor

111 g personal PID monitor from Ion Science: volatile organic compounds up to 5000 ppm with resolution down to 0.001 ppm, a TAC version for benzene, STEL and TWA alarms, up to 12 h runtime, ATEX and IECEx.

  • PID with Fence Electrode
  • 10.6 eV; 10.0 eV TAC; 11.7 eV
Price on requestLearn more

Need advice?

Our specialists will help you choose the optimal Ion Science Tiger XT Select — handheld benzene detector configuration for your equipment.

Часто задаваемые вопросы