Key features

111 g, clips to clothing in the breathing zone
Versions: 10.6 eV (VOC), 10.0 eV TAC (benzene and aromatics), 11.7 eV
Range up to 5000 ppm, resolution 0.1 / 0.01 / 0.001 ppm
Upgradeable from ppm to ppb without replacing the instrument
Pre-programmed STEL and TWA levels
95 dB sounder, vibration and LEDs
30,000-reading memory
ATEX II 1G Ex ia IIC T4 Ga, IECEx

Industry solutions, landing pages and articles on Ion Science Cub — personal VOC monitor

Typical tasks

  • Personal exposure monitoring at refineries and petrochemical plants
  • Benzene monitoring for loading operators and samplers (Cub TAC)
  • Work inside tanks and confined spaces
  • Paint shops and chemical plants
  • Emergency response

Overview

The Cub is a personal photoionisation monitor from the British company Ion Science. It weighs 111 grams, clips to clothing near the breathing zone and shows throughout the day how much volatile organic compound a worker is breathing. When a threshold is exceeded it sounds, vibrates and flashes.

Ion Science Cub

Versions

Version Lamp Purpose Resolution
Cub 10.6 eV most VOCs 0.1 ppm (ppm) or 0.001 ppm (ppb)
Cub TAC 10.0 eV aromatics, benzene 0.01 ppm
Cub 11.7 eV 11.7 eV high ionisation potential compounds —

A ppm unit can be upgraded to ppb without replacing the instrument.

Exposure monitoring

  • STEL — 15-minute short-term exposure.
  • TWA — 8-hour shift time-weighted average.
  • Memory for 30,000 readings at a selectable interval, for occupational health reports.

Technical specifications

Parameter Value
Principle PID, Fence Electrode
Range 0–5000 ppm
T90 under 13 s
Alarms LEDs, 95 dB at 300 mm, vibration
Data logging 30,000 readings
Power up to 12 h, 4 h charge
Display backlit colour LCD
Connectivity USB 2.0, Cub PC software, docking station
Certification ATEX II 1G Ex ia IIC T4 Ga; IECEx
Protection IP65 with PTFE filter
Operating temperature −20 to +60 °C
Dimensions 61 × 66 × 59 mm
Weight 111 g

How the Cub complements other instruments

Task Instrument
Exposure of an individual worker Cub
Rounds, leak finding, confined space entry Tiger XT
Isolating benzene in a mixture on rounds Tiger XT Select
Continuous monitoring at a point Falco 2, Titan 2

Supply in Kazakhstan

KEG TRK is the official representative of Ion Science in Kazakhstan. We supply personal monitors and docking stations and arrange calibration and training. Price on request.

Manufacturer

Ion Science

CubCub

111 g personal PID monitor from Ion Science: volatile organic compounds up to 5000 ppm with resolution down to 0.001 ppm, a TAC version for benzene, STEL and TWA alarms, up to 12 h runtime, ATEX and IECEx.

Key specifications

Technology
PID with Fence Electrode
Versions
10.6 eV; 10.0 eV TAC; 11.7 eV
Range
0–5000 ppm
Resolution
ppm 0.1; ppb 0.001; TAC 0.01 ppm
Response T90
under 13 s

Official supplier in Kazakhstan

Related products

Ion Science Tiger XT — handheld PID detector for volatile organic compounds
Ion ScienceTiger XT

Ion Science Tiger XT — handheld PID detector for volatile organic compounds

Intrinsically safe Ion Science photoionisation detector for over 750 volatile organic compounds: 1 ppb to 20,000 ppm, T90 under 2 s, Fence Electrode technology against humidity and contamination, up to 24 h runtime and 120,000 logged readings.

  • photoionisation detector (PID), Fence Electrode
  • over 750 VOCs and toxic compounds
Price on requestLearn more
Ion Science Tiger XT Select — handheld benzene detector
Ion ScienceTiger XT Select

Ion Science Tiger XT Select — handheld benzene detector

Intrinsically safe Ion Science PID detector for selective benzene measurement from 0.01 ppm with pre-filter tubes, total aromatic compounds (TAC) with STEL and TWA, and total VOC from 1 ppb in standard mode.

  • PID, 10.0 eV lamp, Fence Electrode
  • 0.01–200 ppm (up to 639 mg/m³), 0.001 ppm resolution
Price on requestLearn more
Ion Science Titan 2 — fixed benzene monitor
Ion ScienceTitan 2

Ion Science Titan 2 — fixed benzene monitor

Flameproof fixed benzene monitor: MiniPID sensor with a proprietary separation method, 20 ppb – 20 ppm range, one reading per minute, 4–20 mA, RS485 Modbus and two relays. Ex db IIB+H2 T4 Gb, IP65.

  • fixed benzene monitor
  • MiniPID T2, 10.0 eV, proprietary separation method
Price on requestLearn more
Ion Science Falco 2 — fixed PID VOC detector
Ion ScienceFalco 2

Ion Science Falco 2 — fixed PID VOC detector

Flameproof fixed photoionisation detector for over 700 volatile organic compounds: diffused or pumped, ranges from 0–10 to 0–3000 ppm, a TAC version for benzene, 4–20 mA, RS485 Modbus and two relays.

  • MiniPID 2 PID, Fence Electrode, Typhoon
  • 10.6 eV; 10.0 eV (TAC — aromatics)
Price on requestLearn more