Supply in Kazakhstan
KEG TRK supplies equipment diagnostics solutions (Ion Science) across Kazakhstan: Almaty, Astana, Karaganda, Ust-Kamenogorsk, Aktobe and other regions. Official warranty, monitoring system design, installation, commissioning and personnel training.
Key features
Applications and resources
Industry solutions, landing pages and articles on Ion Science Titan 2 — fixed benzene monitor
Typical tasks
- Benzene monitoring at pump houses and loading racks
- Reformers and aromatics units
- Petroleum product tank farms
- Perimeter of refineries and chemical plants
- Workplace air monitoring in process buildings
Overview
The Titan 2 is a fixed benzene monitor from the British company Ion Science. Installed in a hazardous area, it measures benzene specifically, not total hydrocarbons, once a minute around the clock. This matters at refineries and petrochemical plants, where benzene is mixed with other vapours and its exposure limits are very low.

How it works
- MiniPID T2 sensor with a 10.0 eV lamp and Ion Science's proprietary separation method excludes other gases.
- Sampling by pump at 100 ml/min or more through a PTFE line up to 10 m long, so the monitor can sit in a convenient spot while sampling where needed.
- Range from 20 ppb to 20 ppm with 10 ppb resolution.
- Accuracy ±50 ppb or ±10 %, and ±10 ppb for readings up to 0.1 ppm.
Integration
| Interface | Purpose |
|---|---|
| Isolated 4–20 mA | analogue signal to PLC or DCS |
| RS485 Modbus ASCII/RTU | digital link to the control system |
| 2 relays, 24 V DC 1.25 A | alarm and fault |
| Micro USB | configuration and data download |
| At least 2 GB memory | six months or more of history |
Technical specifications
| Parameter | Value |
|---|---|
| Sensor | MiniPID T2, 10.0 eV |
| Range | 0.02–20 ppm |
| Resolution | 10 ppb |
| Measurement frequency | once per minute |
| Sampling | at least 100 ml/min, PTFE 6/4 mm line up to 10 m |
| Power | 24 V DC (19–32 V), 3.2 A |
| Certification | ATEX II 2G Ex db IIB+H2 T4 Gb; IECEx |
| Protection | IP65 |
| Operating temperature | −20 to +50 °C (ATEX to +55 °C) |
| Humidity | 0–99 % |
| Dimensions | 219 × 219 × 172 mm |
| Weight | 15 kg |
Maintenance
| Interval | Replaced parts |
|---|---|
| 6 months | PID lamp, electrode stack, inline filter, restrictor, hydrophobic and carbon filters |
| 12 months | Airsep filter as well |
Fixed and portable monitoring
The Titan 2 watches one point continuously. For rounds and locating sources, use the portable Tiger XT Select; for personal monitoring, the wearable Cub. For fixed total VOC monitoring, see Falco.
Supply in Kazakhstan
KEG TRK is the official representative of Ion Science in Kazakhstan. We help choose installation points and arrange supply, commissioning and service. Price on request.
Technical specifications
| Type | fixed benzene monitor |
| Sensor | MiniPID T2, 10.0 eV, proprietary separation method |
| Range | 0.02–20 ppm (20 ppb – 20 ppm) |
| Resolution | 10 ppb |
| Accuracy | ±50 ppb or ±10 % (greater); ±10 ppb up to 0.1 ppm |
| Measurement frequency | once per minute |
| Outputs | isolated 4–20 mA; RS485 Modbus ASCII/RTU; 2 relays 24 V DC 1.25 A |
| Data storage | at least 2 GB (over 6 months) |
| PC connection | Micro USB |
| Sampling | at least 100 ml/min, PTFE line up to 10 m |
| Power | 24 V DC (19–32 V), 3.2 A |
| Certification | ATEX II 2G Ex db IIB+H2 T4 Gb; IECEx |
| Protection | IP65 |
| Operating temperature | −20 to +50 °C (ATEX to +55 °C) |
| Humidity | 0–99 % |
| Dimensions | 219 × 219 × 172 mm |
| Weight | 15 kg |
Applications
Manufacturer
Ion Science
Flameproof fixed benzene monitor: MiniPID sensor with a proprietary separation method, 20 ppb – 20 ppm range, one reading per minute, 4–20 mA, RS485 Modbus and two relays. Ex db IIB+H2 T4 Gb, IP65.
Key specifications
- Type
- fixed benzene monitor
- Sensor
- MiniPID T2, 10.0 eV, proprietary separation method
- Range
- 0.02–20 ppm (20 ppb – 20 ppm)
- Resolution
- 10 ppb
- Accuracy
- ±50 ppb or ±10 % (greater); ±10 ppb up to 0.1 ppm
Official supplier in Kazakhstan
Related products

Ion Science Tiger XT Select — handheld benzene detector
Intrinsically safe Ion Science PID detector for selective benzene measurement from 0.01 ppm with pre-filter tubes, total aromatic compounds (TAC) with STEL and TWA, and total VOC from 1 ppb in standard mode.
- PID, 10.0 eV lamp, Fence Electrode
- 0.01–200 ppm (up to 639 mg/m³), 0.001 ppm resolution

Ion Science Falco 2 — fixed PID VOC detector
Flameproof fixed photoionisation detector for over 700 volatile organic compounds: diffused or pumped, ranges from 0–10 to 0–3000 ppm, a TAC version for benzene, 4–20 mA, RS485 Modbus and two relays.
- MiniPID 2 PID, Fence Electrode, Typhoon
- 10.6 eV; 10.0 eV (TAC — aromatics)

Ion Science Cub — personal VOC monitor
111 g personal PID monitor from Ion Science: volatile organic compounds up to 5000 ppm with resolution down to 0.001 ppm, a TAC version for benzene, STEL and TWA alarms, up to 12 h runtime, ATEX and IECEx.
- PID with Fence Electrode
- 10.6 eV; 10.0 eV TAC; 11.7 eV

Ion Science Tiger XT — handheld PID detector for volatile organic compounds
Intrinsically safe Ion Science photoionisation detector for over 750 volatile organic compounds: 1 ppb to 20,000 ppm, T90 under 2 s, Fence Electrode technology against humidity and contamination, up to 24 h runtime and 120,000 logged readings.
- photoionisation detector (PID), Fence Electrode
- over 750 VOCs and toxic compounds
Need advice?
Our specialists will help you choose the optimal Ion Science Titan 2 — fixed benzene monitor configuration for your equipment.
Related articles
All articles →
KEG TRK becomes the official representative of Ion Science in Kazakhstan
As of September 2026, KEG TRK LLP is the official representative of British gas-detection manufacturer Ion Science in Kazakhstan: SF6 leak detectors, VOC detectors, supply, service and training.

Gas and VOC Leak Detection on Industrial Sites: Ion Science PID Detectors
How to choose a PID detector for gas and volatile organic compound leaks: Ion Science personal, portable and fixed instruments, LDAR programmes and the pairing with ultrasound.