How to find a leak in a pneumatic cylinder and actuator
A pneumatic cylinder leak is checked at rest and during the stroke: external leakage by the hiss at the rod and fittings, internal leakage by the valve exhaust. How to test with ultrasound, rank the findings and set the repair order.
In this article
LEAKChecker with its flexible sensor at a pneumatic cylinder and valve manifold: rod seal, fittings and hoses are checked. The scene is recreated from the manufacturer image of the instrument.
KEG TRKAuthor: Georgy Cheredeev, Technical Director, KEG TRK · Updated: November 24, 2026 · How we prepare our content
A pneumatic cylinder leak is checked in two modes: in the pause of the cycle and during the stroke. External leakage at the rod, the end caps and the fittings is heard with an airborne ultrasonic sensor as a hiss. Internal leakage past the piston goes into the opposite chamber and out through the valve exhaust: the cylinder stands still while air comes from the silencer. Compare the unit with an identical healthy one and tag what you find.

AI-generated illustration: a compressed air line with threaded joints. This is not a photograph from a customer site.
How does leak detection on a pneumatic actuator differ from surveying the whole network?
The general route from the compressor room to the consumers is described in how to find a compressed air leak in production: 5 methods and the leak inspection route. The money that leaks away is calculated as in how much compressed air leaks cost. This article is about something else: a single actuator on a machine, where the leak can have several causes and places.
A pneumatic drive has two special features. First, its air normally goes out at every stroke, so normal exhaust must not be mistaken for a defect. Second, leakage can be internal: air passes the piston or the valve spool and leaves where it is not expected, while the cylinder looks dry from outside.
Where does a pneumatic actuator lose air?
The unit can be split into several places, and each is checked separately.
- Fittings and hoses. Push-in and threaded joints, hose entries, kinks, cracks near the ends.
- Valve sub-base and directional valve. Joints between sub-bases, gaskets between blocks, exhaust silencers, spool wear.
- Rod seal. Air comes out along the rod during the stroke and in the pause. Causes: a worn or pinched seal, scored rod, worn gland bearing, seal incompatible with the lubricant.
- Piston seal. Air passes into the opposite chamber. Causes: a worn seal, a scored bore, contamination of the circuit.
- Air preparation. Filter, regulator and drains near the machine.
Causes of seal wear are listed in the Valmet pneumatic troubleshooting guide: contamination of the circuit (dirt, sealant inside fittings, burrs), a damaged rod surface and misaligned load. Replacing the seal without removing such a cause gives a repeat failure.
Equipment covered in this article

SDT340 - Advanced Ultrasound Detector
The most advanced ultrasound detector for collecting, analysing and trending data
What do external and internal leaks look like?
| Symptom | Likely cause | What ultrasound shows | Next action |
|---|---|---|---|
| Hiss at the rod, in the pause and during the stroke | Worn rod seal, damaged rod | Source at the rod exit, signal rises as the sensor approaches | Check the rod and the gland, replace the seal at a planned stop |
| Hiss at a fitting or hose | Loose collet, crack, poor thread seal | A point source on the connection | Tighten or replace the fitting, repeat the reading |
| Air keeps coming from the valve silencer while the cylinder is still | Leakage past the piston or the spool | Steady signal at the exhaust port in the pause; compare with an identical unit | Separate cylinder from valve; replace seals or the unit |
| The cylinder drifts or does not hold position with the chamber blocked | Leakage past the piston seal | Signal on the cylinder body and at the exhaust of the opposite chamber | Replace the piston seal, check the bore |
| Signal at the joint between sub-bases | Leaking gasket | Source between valve blocks | Replace gaskets, tighten the tie rods |
| A signal but no visible leak | Reflection from a wall or a neighbouring unit | The maximum moves when the direction changes | Move closer, change position, confirm the source |
How do you find a leak in a pneumatic cylinder step by step?
- Record the condition: pressure, cylinder position, neighbouring machines running. Work near moving parts follows the lockout procedure. Neither hand nor sensor may be in the stroke zone.
- Stop the cycle in an end position where the chamber keeps pressure. This is the reading "at rest".
- Survey the unit with an airborne sensor: fittings, hoses, sub-base, silencers, cylinder caps and rod. Follow the rising sound to the source, as in the ultrasonic inspection guide.
- In the pause, check the exhaust port of the valve. According to Valmet, piston leakage shows as flow from the exhaust ports with the cylinder stopped: if the flow is excessive, the seals are replaced.
- To tell cylinder from valve, put a contact sensor on the cylinder body and on the valve body and compare with an identical healthy unit. A sensor on the body picks up sound travelling through metal.
- Run the cycle in normal mode and listen to the rod and caps during the stroke. Exhaust at reversal is normal: look for a hiss that remains in the pause or comes from the side.
- Give the point a number, photograph it, record the pressure, position and condition. Then repair and repeat the reading under the same conditions.
Suitable instruments are the SDT340 with airborne and contact sensors and the dedicated LEAKChecker detector. For regular surveys with reports, use LEAKReporter.
How do you rank the leaks you found?
The signal level alone is not enough for priority. Consider:
- the signal strength at the same distance and gain: stronger means larger;
- time under pressure: a leak on a machine that idles at night and at weekends runs round the clock;
- repair effort: a fitting is changed in minutes, a cylinder needs a stop;
- impact on quality and safety: a cylinder that drifts matters more than one with a light hiss at a fitting.
The cost of losses is estimated in the compressed air leak calculator: enter the flow, hours of operation, specific energy and your own tariff. The flow cannot be calculated from the dB level. The US Department of Energy (DOE) notes that without regular maintenance about 20 % of compressor output is lost to leaks, and with regular finding and repair they are kept below 10 %.
In what order should repairs be done?
- Fittings, hoses and drains: quick, cheap, the effect is visible at once.
- Joints between sub-bases, gaskets and valve silencers.
- Rod seals: check the rod for scoring and the gland for wear.
- Piston seals or the whole cylinder, at a planned stop, with a check of the bore and of the causes of wear.
- A repeat reading at the same points. If the cylinder moves more slowly than usual after repair, check the throttle settings.
If a pneumatic drive operates a vacuum gripper, air is also lost in the gripper circuit: see the article on suction cups that do not hold the workpiece and finding an air ingress in a vacuum system. The pneumatic actuator of a control valve is checked in the same way, while the valve itself is checked for leakage with the methods in the articles on shut-off valves and relief valves.
What are the limits of the method?
- Airborne ultrasound finds external leaks. Internal leakage past the piston is seen indirectly at the exhaust and with a contact sensor, but the method does not show the exact source inside the cylinder.
- The dB level says nothing about flow or whether the cylinder develops enough force. Force and speed are checked separately.
- Noise from neighbouring machines, reflections from walls and normal exhaust give false maxima. Confirm the source from several sides.
- No signal does not prove tightness: a small flow or blocked access may not be audible.
- For the port-to-port test and for disassembly the unit is isolated and depressurised under the procedure.
General principles of leak detection and instruments: finding leaks of compressed air and gas. To choose a kit for your machines, contact KEG TRK.
Sources
- Valmet, These pneumatic troubleshooting charts cover many common problems, 2016: checking the piston seal by flow from the exhaust ports, causes of seal wear.
- U.S. Department of Energy, Compressed Air Challenge, Compressed Air System Leaks (Fact Sheet 7): the share of leaks in systems without maintenance and with regular repair.
- SDT Ultrasound Solutions: materials on airborne and contact sensors, product pages SDT340 and LEAKChecker.
See also
Frequently asked questions
Equipment in this article
KEG TRK quotes prices and delivery times to Kazakhstan on request. We will prepare a commercial offer for your application.

SDT340 - Advanced Ultrasound Detector
The most advanced ultrasound detector for collecting, analysing and trending data

SDT LEAKChecker — Ultrasonic Leak Detector
Find compressed-air leaks and vacuum ingress with SDT LEAKChecker. Specifications, original kit, survey workflow and equipment selection in Kazakhstan.
Read also
10/6/2026
Compressed air leak detection: inspection route and repair verification
How to find compressed air leaks in a plant: inspection route, ultrasonic detector selection, defect register and verification after repairs.
10/6/2026
Vacuum suction cup will not hold: causes and air ingress inspection
Separate hose and fitting leaks, cup wear, workpiece porosity and insufficient vacuum generation before changing the operating settings.
11/24/2026
A hydraulic pump is noisy: cavitation, aeration or wear, and how to tell them apart
A hydraulic pump whines or rattles: is it starved of oil, sucking air or worn out? How to separate the three causes by symptoms and ultrasound, where to put the sensor and what to fix first.